{"title":"评估 ATLHAMC12 子信道编码在完全断流情况下的性能","authors":"Tomáš Křeček, Š. Foral","doi":"10.14311/app.2023.44.0013","DOIUrl":null,"url":null,"abstract":"The ALTHAMC12 subchannel code is a new subchannel code developed by the ALVEL company. The code is intended for DNBR safety analyses of the Czech nuclear power plants. In order to validate the code, a code to code comparison with THALES and VIPRE-01 is provided in this work. The reactor core model was developed and set of initial and boundary conditions has been adopted from a reference study. The comparison is done for steady state nominal parameters and Total Loss of Flow (TLOF) type of accident. The results show that ALTHAMC12 provides a good agreement with the reference codes in the terms of MDNBR value and its positions in the reactor core.","PeriodicalId":7150,"journal":{"name":"Acta Polytechnica CTU Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of ATLHAMC12 subchannel code for total loss of flow scenario\",\"authors\":\"Tomáš Křeček, Š. Foral\",\"doi\":\"10.14311/app.2023.44.0013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The ALTHAMC12 subchannel code is a new subchannel code developed by the ALVEL company. The code is intended for DNBR safety analyses of the Czech nuclear power plants. In order to validate the code, a code to code comparison with THALES and VIPRE-01 is provided in this work. The reactor core model was developed and set of initial and boundary conditions has been adopted from a reference study. The comparison is done for steady state nominal parameters and Total Loss of Flow (TLOF) type of accident. The results show that ALTHAMC12 provides a good agreement with the reference codes in the terms of MDNBR value and its positions in the reactor core.\",\"PeriodicalId\":7150,\"journal\":{\"name\":\"Acta Polytechnica CTU Proceedings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Polytechnica CTU Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14311/app.2023.44.0013\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Polytechnica CTU Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14311/app.2023.44.0013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of ATLHAMC12 subchannel code for total loss of flow scenario
The ALTHAMC12 subchannel code is a new subchannel code developed by the ALVEL company. The code is intended for DNBR safety analyses of the Czech nuclear power plants. In order to validate the code, a code to code comparison with THALES and VIPRE-01 is provided in this work. The reactor core model was developed and set of initial and boundary conditions has been adopted from a reference study. The comparison is done for steady state nominal parameters and Total Loss of Flow (TLOF) type of accident. The results show that ALTHAMC12 provides a good agreement with the reference codes in the terms of MDNBR value and its positions in the reactor core.