针对创伤后髋臼畸形和缺陷的定制植入物的生物固定技术

Q3 Medicine
V. A. Bazlov, A. A. Pronskikh, A. A. Korytkin, T. Z. Mamuladze, M. V. Efimenko, V. V. Pavlov
{"title":"针对创伤后髋臼畸形和缺陷的定制植入物的生物固定技术","authors":"V. A. Bazlov, A. A. Pronskikh, A. A. Korytkin, T. Z. Mamuladze, M. V. Efimenko, V. V. Pavlov","doi":"10.18019/1028-4427-2023-29-6-609-614","DOIUrl":null,"url":null,"abstract":"Introduction The number of surgical interventions using additive technologies in medicine has been growing both in Russia and with every year. Due to the development of printing customized implants, the use of standard (imported) designs has decreased by an average of 7 % in the provision of high-tech medical care. However, the issue of the pore size of customized implants for management of post-traumatic defects in the acetabulum remains open.Objective To evaluate the results of the treatment of patients with post-traumatic acetabulum defects and deformities with the implementation in clinical practice of customized implants with structure and size porous surface that are optimal from the point of view of biological fixation.Material and methods Porous implants with different types of porous structure were produced by direct laser sintering using Ti-6Al-4V titanium alloy powders. Experimental work was carried out in vitro to determine the ability of living fibroblasts to penetrate the pores of different sizes. Next, the clinical part of this study was conducted in order to determine the signs of biological fixation of customized acetabular implants in a group of patients (n = 30).Results The results of this experiment performed to analyze the penetration of living fibroblasts into the porous structure of implants with different pore size demonstrated that metal structures with a pore size of 400-499 μm can be singled out from all others. Discussion Analysis of the literature data shows that there is no consensus on the structure and size of the pores of a customized implant. In our work, we investigated the ability of human living fibroblasts to penetrate into the surface structure of a customized implant, as a result of which we determined their optimal pore size of 400-499 microns. It should be noted that this study was conducted for a definite anatomical location: the acetabulum. However, it cannot be excluded that the data obtained are relevant for other anatomical locations.Conclusion Management of bone defects in the acetabulum area with customized implants featuring the surface pore size of 400-499 microns is a justified and relevant method. A prerequisite for the use of such implants is strict compliance with the indications for their use, careful preoperative planning and correct positioning.","PeriodicalId":37426,"journal":{"name":"Genij Ortopedii","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biological fixation of customized implants for post-traumatic acetabular deformities and defects\",\"authors\":\"V. A. Bazlov, A. A. Pronskikh, A. A. Korytkin, T. Z. Mamuladze, M. V. Efimenko, V. V. Pavlov\",\"doi\":\"10.18019/1028-4427-2023-29-6-609-614\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction The number of surgical interventions using additive technologies in medicine has been growing both in Russia and with every year. Due to the development of printing customized implants, the use of standard (imported) designs has decreased by an average of 7 % in the provision of high-tech medical care. However, the issue of the pore size of customized implants for management of post-traumatic defects in the acetabulum remains open.Objective To evaluate the results of the treatment of patients with post-traumatic acetabulum defects and deformities with the implementation in clinical practice of customized implants with structure and size porous surface that are optimal from the point of view of biological fixation.Material and methods Porous implants with different types of porous structure were produced by direct laser sintering using Ti-6Al-4V titanium alloy powders. Experimental work was carried out in vitro to determine the ability of living fibroblasts to penetrate the pores of different sizes. Next, the clinical part of this study was conducted in order to determine the signs of biological fixation of customized acetabular implants in a group of patients (n = 30).Results The results of this experiment performed to analyze the penetration of living fibroblasts into the porous structure of implants with different pore size demonstrated that metal structures with a pore size of 400-499 μm can be singled out from all others. Discussion Analysis of the literature data shows that there is no consensus on the structure and size of the pores of a customized implant. In our work, we investigated the ability of human living fibroblasts to penetrate into the surface structure of a customized implant, as a result of which we determined their optimal pore size of 400-499 microns. It should be noted that this study was conducted for a definite anatomical location: the acetabulum. However, it cannot be excluded that the data obtained are relevant for other anatomical locations.Conclusion Management of bone defects in the acetabulum area with customized implants featuring the surface pore size of 400-499 microns is a justified and relevant method. A prerequisite for the use of such implants is strict compliance with the indications for their use, careful preoperative planning and correct positioning.\",\"PeriodicalId\":37426,\"journal\":{\"name\":\"Genij Ortopedii\",\"volume\":\"5 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Genij Ortopedii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18019/1028-4427-2023-29-6-609-614\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Genij Ortopedii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18019/1028-4427-2023-29-6-609-614","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

引言 在俄罗斯,使用添加剂技术进行外科手术的数量逐年增加。由于打印定制植入物的发展,在提供高科技医疗服务方面,标准(进口)设计的使用量平均减少了 7%。目的 从生物固定的角度评估在临床实践中使用具有最佳结构和尺寸多孔表面的定制植入物治疗创伤后髋臼缺损和畸形患者的效果。材料和方法 使用 Ti-6Al-4V 钛合金粉末通过直接激光烧结法生产具有不同类型多孔结构的多孔植入物。实验工作在体外进行,以确定活的成纤维细胞穿透不同大小孔隙的能力。结果 实验分析了活的成纤维细胞穿透不同孔径的植入物多孔结构的能力,结果表明,孔径为 400-499 μm 的金属结构可以从所有其他结构中脱颖而出。讨论 对文献数据的分析表明,对于定制植入体的孔隙结构和大小还没有达成共识。在我们的工作中,我们研究了活体成纤维细胞渗入定制植入体表面结构的能力,并由此确定其最佳孔径为 400-499 微米。值得注意的是,这项研究是针对一个明确的解剖位置进行的:髋臼。结论 使用表面孔径为 400-499 微米的定制植入体治疗髋臼部位的骨缺损是一种合理且相关的方法。使用此类植入物的前提条件是严格遵守其使用适应症、仔细的术前规划和正确的定位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Biological fixation of customized implants for post-traumatic acetabular deformities and defects
Introduction The number of surgical interventions using additive technologies in medicine has been growing both in Russia and with every year. Due to the development of printing customized implants, the use of standard (imported) designs has decreased by an average of 7 % in the provision of high-tech medical care. However, the issue of the pore size of customized implants for management of post-traumatic defects in the acetabulum remains open.Objective To evaluate the results of the treatment of patients with post-traumatic acetabulum defects and deformities with the implementation in clinical practice of customized implants with structure and size porous surface that are optimal from the point of view of biological fixation.Material and methods Porous implants with different types of porous structure were produced by direct laser sintering using Ti-6Al-4V titanium alloy powders. Experimental work was carried out in vitro to determine the ability of living fibroblasts to penetrate the pores of different sizes. Next, the clinical part of this study was conducted in order to determine the signs of biological fixation of customized acetabular implants in a group of patients (n = 30).Results The results of this experiment performed to analyze the penetration of living fibroblasts into the porous structure of implants with different pore size demonstrated that metal structures with a pore size of 400-499 μm can be singled out from all others. Discussion Analysis of the literature data shows that there is no consensus on the structure and size of the pores of a customized implant. In our work, we investigated the ability of human living fibroblasts to penetrate into the surface structure of a customized implant, as a result of which we determined their optimal pore size of 400-499 microns. It should be noted that this study was conducted for a definite anatomical location: the acetabulum. However, it cannot be excluded that the data obtained are relevant for other anatomical locations.Conclusion Management of bone defects in the acetabulum area with customized implants featuring the surface pore size of 400-499 microns is a justified and relevant method. A prerequisite for the use of such implants is strict compliance with the indications for their use, careful preoperative planning and correct positioning.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Genij Ortopedii
Genij Ortopedii Medicine-Surgery
CiteScore
0.70
自引率
0.00%
发文量
104
审稿时长
12 weeks
期刊介绍: Journal’s main goal is to contribute to the development of the contemporary medical science via presentation of fundamental and applied original scientific studies to the scientific and practical medical community that would widen and deepen the understanding of the most important problems in the field of traumatology, orthopaedics, and related specialties. Our journal provides a direct open access to its content which is based on the principle that the open access option promotes global exchange of knowledge and experience. Journal’s strategy: -Development of the journal as a scientific platform for researchers, doctors, post-graduates and residents -Attraction of highly-cited authors to publish their studies -Selection of manuscripts of scientific interest for readers that will impact on journal citation index in RINC -Increase in the portion of publications submitted by foreign authors and studies conducted in association with foreign scientists; growth of citations in the journals that are included into global systems of indexing and reputable databases -Improvement of the Journal’s web site in two languages for a greater accessibility by authors and readers -Introduction of the Journal into global indexing systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信