Carlos M. Lucero, J. B. Luco, A. Garcia-Mansilla, P. Slullitel, G. Zanotti, Fernando Comba, Martin A Buttaro
{"title":"使用皮质窗截骨技术成功完成现代股骨干再骨折后的髋关节翻修手术:病例报告和文献综述","authors":"Carlos M. Lucero, J. B. Luco, A. Garcia-Mansilla, P. Slullitel, G. Zanotti, Fernando Comba, Martin A Buttaro","doi":"10.5662/wjm.v13.i5.502","DOIUrl":null,"url":null,"abstract":"BACKGROUND\n The ExeterTM Universal cemented femoral component is widely used for total hip replacement surgery. Although there have been few reports of femoral component fracture, removal of a broken femoral stem can be a challenging procedure.\n CASE SUMMARY\n A 54-year-old man with a Dorr A femur sustained a refracture of a primary ExeterTM stem, two years after receiving a revision using a cement-within-cement technique (CWC) through an extended trochanteric osteotomy (ETO). The technical problems related to the CWC technique and the ETO played a major role in the stem fatigue refracture. We performed revision surgery and removed the distal cement using a cortical femoral window technique, followed by re-implantation with an uncemented, modular, distally-fixed uncemented stem. The patient experienced an uneventful postoperative recovery.\n CONCLUSION\n Re-fracture of a modern femoral ExeterTM stem is a rare event, but technical complications related to revision surgery can lead to this outcome. The cortical window osteotomy technique can facilitate the removal of a broken stem and cement, allowing for prosthetic re-implantation under direct vision and avoiding ETO-related complications.","PeriodicalId":94271,"journal":{"name":"World journal of methodology","volume":"57 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Successful hip revision surgery following refracture of a modern femoral stem using a cortical window osteotomy technique: A case report and review of literature\",\"authors\":\"Carlos M. Lucero, J. B. Luco, A. Garcia-Mansilla, P. Slullitel, G. Zanotti, Fernando Comba, Martin A Buttaro\",\"doi\":\"10.5662/wjm.v13.i5.502\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND\\n The ExeterTM Universal cemented femoral component is widely used for total hip replacement surgery. Although there have been few reports of femoral component fracture, removal of a broken femoral stem can be a challenging procedure.\\n CASE SUMMARY\\n A 54-year-old man with a Dorr A femur sustained a refracture of a primary ExeterTM stem, two years after receiving a revision using a cement-within-cement technique (CWC) through an extended trochanteric osteotomy (ETO). The technical problems related to the CWC technique and the ETO played a major role in the stem fatigue refracture. We performed revision surgery and removed the distal cement using a cortical femoral window technique, followed by re-implantation with an uncemented, modular, distally-fixed uncemented stem. The patient experienced an uneventful postoperative recovery.\\n CONCLUSION\\n Re-fracture of a modern femoral ExeterTM stem is a rare event, but technical complications related to revision surgery can lead to this outcome. The cortical window osteotomy technique can facilitate the removal of a broken stem and cement, allowing for prosthetic re-implantation under direct vision and avoiding ETO-related complications.\",\"PeriodicalId\":94271,\"journal\":{\"name\":\"World journal of methodology\",\"volume\":\"57 10\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World journal of methodology\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.5662/wjm.v13.i5.502\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World journal of methodology","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.5662/wjm.v13.i5.502","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Successful hip revision surgery following refracture of a modern femoral stem using a cortical window osteotomy technique: A case report and review of literature
BACKGROUND
The ExeterTM Universal cemented femoral component is widely used for total hip replacement surgery. Although there have been few reports of femoral component fracture, removal of a broken femoral stem can be a challenging procedure.
CASE SUMMARY
A 54-year-old man with a Dorr A femur sustained a refracture of a primary ExeterTM stem, two years after receiving a revision using a cement-within-cement technique (CWC) through an extended trochanteric osteotomy (ETO). The technical problems related to the CWC technique and the ETO played a major role in the stem fatigue refracture. We performed revision surgery and removed the distal cement using a cortical femoral window technique, followed by re-implantation with an uncemented, modular, distally-fixed uncemented stem. The patient experienced an uneventful postoperative recovery.
CONCLUSION
Re-fracture of a modern femoral ExeterTM stem is a rare event, but technical complications related to revision surgery can lead to this outcome. The cortical window osteotomy technique can facilitate the removal of a broken stem and cement, allowing for prosthetic re-implantation under direct vision and avoiding ETO-related complications.