优化液相色谱串联质谱法快速筛查血液中药物的方法。

IF 1.1 Q4 MEDICAL LABORATORY TECHNOLOGY
Advances in laboratory medicine Pub Date : 2023-11-23 eCollection Date: 2023-12-01 DOI:10.1515/almed-2023-0154
Alba M Rodrigo Valero, Oscar Quintela Jorge, Begoña Bravo Serrano, Sara Ayuso Tejedor
{"title":"优化液相色谱串联质谱法快速筛查血液中药物的方法。","authors":"Alba M Rodrigo Valero, Oscar Quintela Jorge, Begoña Bravo Serrano, Sara Ayuso Tejedor","doi":"10.1515/almed-2023-0154","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>In the recent years, liquid chromatography with tandem mass spectrometry has gained popularity in laboratories. This technique has a higher specificity, detects different analytes from a single specimen, measures analytes in distinct matrices, and substantially reduce analytical interference, with respect to immunoassay. The processing and preparation of biological samples are crucial in chromatography. Interferences in blood testing are usually caused by the presence of phospholipids and proteins. The main objective of this study was to improve analytical processes for drug screening by LC-MS/MS using a novel blood sample preparation method based on protein precipitation and removal of phospholipids.</p><p><strong>Methods: </strong>An evaluation was performed of a new method for the preparation of blood samples based on protein precipitation and removal of phospholipids by LC-Q-q-LIT.</p><p><strong>Results: </strong>Limit of detection, limit of quantification and measurement range were determined for 56 molecules. The results of 11 cases were compared with those obtained using standard blood collection methods and instruments.</p><p><strong>Conclusions: </strong>The novel blood preparation and testing method based on LC-Q-q-LIT, a more sensitive technique, has demonstrated to yield comparable results to traditional methods. In addition, this new technique reduces turnaround time and costs.</p>","PeriodicalId":72097,"journal":{"name":"Advances in laboratory medicine","volume":"4 4","pages":"365-371"},"PeriodicalIF":1.1000,"publicationDate":"2023-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10724859/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optimization of a rapid method for screening drugs in blood by liquid chromatography tandem mass spectrometry.\",\"authors\":\"Alba M Rodrigo Valero, Oscar Quintela Jorge, Begoña Bravo Serrano, Sara Ayuso Tejedor\",\"doi\":\"10.1515/almed-2023-0154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>In the recent years, liquid chromatography with tandem mass spectrometry has gained popularity in laboratories. This technique has a higher specificity, detects different analytes from a single specimen, measures analytes in distinct matrices, and substantially reduce analytical interference, with respect to immunoassay. The processing and preparation of biological samples are crucial in chromatography. Interferences in blood testing are usually caused by the presence of phospholipids and proteins. The main objective of this study was to improve analytical processes for drug screening by LC-MS/MS using a novel blood sample preparation method based on protein precipitation and removal of phospholipids.</p><p><strong>Methods: </strong>An evaluation was performed of a new method for the preparation of blood samples based on protein precipitation and removal of phospholipids by LC-Q-q-LIT.</p><p><strong>Results: </strong>Limit of detection, limit of quantification and measurement range were determined for 56 molecules. The results of 11 cases were compared with those obtained using standard blood collection methods and instruments.</p><p><strong>Conclusions: </strong>The novel blood preparation and testing method based on LC-Q-q-LIT, a more sensitive technique, has demonstrated to yield comparable results to traditional methods. In addition, this new technique reduces turnaround time and costs.</p>\",\"PeriodicalId\":72097,\"journal\":{\"name\":\"Advances in laboratory medicine\",\"volume\":\"4 4\",\"pages\":\"365-371\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10724859/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in laboratory medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/almed-2023-0154\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in laboratory medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/almed-2023-0154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:近年来,液相色谱-串联质谱法在实验室中越来越受欢迎。与免疫测定相比,该技术具有更高的特异性,可从单一样本中检测不同的分析物,测量不同基质中的分析物,并大大减少分析干扰。生物样本的处理和制备对色谱分析至关重要。血液检测中的干扰通常是由于磷脂和蛋白质的存在造成的。本研究的主要目的是采用一种基于蛋白质沉淀和磷脂去除的新型血液样品制备方法,改进 LC-MS/MS 药物筛选的分析流程:方法:通过 LC-Q-q-LIT 对一种基于蛋白质沉淀和磷脂去除的血液样品制备新方法进行了评估:结果:确定了 56 种分子的检测限、定量限和测量范围。结果:确定了 56 种分子的检测限和定量限及测量范围,并将 11 个案例的结果与使用标准采血方法和仪器获得的结果进行了比较:结论:基于 LC-Q-q-LIT 的新型血液制备和检测方法是一种灵敏度更高的技术,其结果与传统方法相当。此外,这项新技术还缩短了周转时间,降低了成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of a rapid method for screening drugs in blood by liquid chromatography tandem mass spectrometry.

Objectives: In the recent years, liquid chromatography with tandem mass spectrometry has gained popularity in laboratories. This technique has a higher specificity, detects different analytes from a single specimen, measures analytes in distinct matrices, and substantially reduce analytical interference, with respect to immunoassay. The processing and preparation of biological samples are crucial in chromatography. Interferences in blood testing are usually caused by the presence of phospholipids and proteins. The main objective of this study was to improve analytical processes for drug screening by LC-MS/MS using a novel blood sample preparation method based on protein precipitation and removal of phospholipids.

Methods: An evaluation was performed of a new method for the preparation of blood samples based on protein precipitation and removal of phospholipids by LC-Q-q-LIT.

Results: Limit of detection, limit of quantification and measurement range were determined for 56 molecules. The results of 11 cases were compared with those obtained using standard blood collection methods and instruments.

Conclusions: The novel blood preparation and testing method based on LC-Q-q-LIT, a more sensitive technique, has demonstrated to yield comparable results to traditional methods. In addition, this new technique reduces turnaround time and costs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信