使用自扩张假体进行经导管主动脉瓣置换术后框架扩张和瓣周漏减少的时间趋势。

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Minerva cardiology and angiology Pub Date : 2024-04-01 Epub Date: 2023-12-12 DOI:10.23736/S2724-5683.23.06368-8
Giulio Russo, Aniello Zambrano, Francesco Burzotta, Daniela Pedicino, Francesca Graziani, Stefano Cangemi, Francesco Bianchini, Piergiorgio Bruno, Gabriella Locorotondo, Michele Calabrese, Cristina Aurigemma, Enrico Romagnoli, Carlo Trani
{"title":"使用自扩张假体进行经导管主动脉瓣置换术后框架扩张和瓣周漏减少的时间趋势。","authors":"Giulio Russo, Aniello Zambrano, Francesco Burzotta, Daniela Pedicino, Francesca Graziani, Stefano Cangemi, Francesco Bianchini, Piergiorgio Bruno, Gabriella Locorotondo, Michele Calabrese, Cristina Aurigemma, Enrico Romagnoli, Carlo Trani","doi":"10.23736/S2724-5683.23.06368-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL.</p><p><strong>Methods: </strong>We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint.</p><p><strong>Results: </strong>Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027).</p><p><strong>Conclusions: </strong>PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.</p>","PeriodicalId":18668,"journal":{"name":"Minerva cardiology and angiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Temporal trends of frame expansion and paravalvular leak reduction after transcatheter aortic valve replacement with self-expandable prostheses.\",\"authors\":\"Giulio Russo, Aniello Zambrano, Francesco Burzotta, Daniela Pedicino, Francesca Graziani, Stefano Cangemi, Francesco Bianchini, Piergiorgio Bruno, Gabriella Locorotondo, Michele Calabrese, Cristina Aurigemma, Enrico Romagnoli, Carlo Trani\",\"doi\":\"10.23736/S2724-5683.23.06368-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL.</p><p><strong>Methods: </strong>We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint.</p><p><strong>Results: </strong>Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027).</p><p><strong>Conclusions: </strong>PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.</p>\",\"PeriodicalId\":18668,\"journal\":{\"name\":\"Minerva cardiology and angiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Minerva cardiology and angiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.23736/S2724-5683.23.06368-8\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva cardiology and angiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S2724-5683.23.06368-8","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:腔静脉旁漏(PVL)是经导管主动脉瓣置换术(TAVR)后的常见症状,会影响后期临床效果。可自行扩张(SE)的经导管心脏瓣膜(THV)更常见。人们对 SE-THV 植入后的扩张知之甚少。我们的目的是评估 SE-THV 支架扩张及其对 PVL 可能产生的影响:我们设计了一项前瞻性试验研究,以评估 SE-THV 支架尺寸和 TAVR 后 PVL 的时间进程。使用 SE-THV 进行 TAVR 的患者连续入组。在 TAVR 术后(T0)和出院前(T1)立即进行假体透视和超声心动图检查,对 PVL 进行分级。在两个透视正交切面上对假体直径进行评估。超声心动图检查时,PVL 从 T0 到 T1 降低≥1+ 是主要研究终点:结果:25 名患者入选。T0和T1评估的平均间隔时间为5天。76%的患者在T0和68%的患者在T1出现1级或2级(P=0.034)。从 T0 到 T1,共有 7 名患者(28%)的 PVL 提高了≥1 级。T0和T1透视直径之间的差异无统计学意义。根据 PVL 变化情况比较直径变化时,PVL 改善的患者(与未改善的患者相比)在环/内流(P=0.016)和流出/远端边缘(P=0.027)的最小直径增幅明显更大:结论:SE-THV术后早期PVL可能会改善,PVL改善的患者THV框架可能会扩大。需要进一步研究来证实这些初步观察结果,并确定这一现象的临床意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Temporal trends of frame expansion and paravalvular leak reduction after transcatheter aortic valve replacement with self-expandable prostheses.

Background: Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL.

Methods: We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint.

Results: Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027).

Conclusions: PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Minerva cardiology and angiology
Minerva cardiology and angiology CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.60
自引率
18.80%
发文量
118
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信