Dongmei Guo, Yiran Xia, Ur Rahman Mujeeb, Jianzhong Wang, Jiawei Liu, Quan Bai
{"title":"[制备基于嵌段共聚物的温度响应型亲和层析固定相,用于抗体分离和纯化]。","authors":"Dongmei Guo, Yiran Xia, Ur Rahman Mujeeb, Jianzhong Wang, Jiawei Liu, Quan Bai","doi":"10.3724/SP.J.1123.2023.09028","DOIUrl":null,"url":null,"abstract":"<p><p>Antibodies play an essential role in cancer diagnosis and treatment because of the specificity for target biomolecules and reduction of side effects. However, antibodies separation and purification still face some challenges. Antibody elution from columns using a low-pH aqueous solution leads to aggregation or loss of activity of the antibody drugs. In this paper, a block copolymer-based temperature-responsive affinity chromatography (TRAC) stationary phase, SiO<sub>2</sub>-P[NIPAM-<i>b</i>-4VP]-MEP using the block temperature-responsive copolymer poly(<i>N</i>-isopropylacrylamide-<i>b</i>-4-vinylpyridine) (P[NIPAM-<i>b</i>-4VP]) as the space arms and 4-mercaptoethyl pyridine (MEP) as the ligand was prepared for antibody separation. The TRAC column was tested using bovine serum albumin (BSA) and <i>γ</i>-globulin as model proteins, and the effects of salt concentration in the mobile phase and temperature on their separation were studied in detail. At 40 ℃, the TRAC stationary phase only selectively retained <i>γ</i>-globulin due to the specific affinity interaction between antibodies and the ligand MEP. At 5 ℃, <i>γ</i>-globulin can be eluted from the column with a mass recovery of 92.7% using a Tris-HCl buffer (pH 8.0) solution containing 0.6 mol/L NaCl. The adsorption capacity of <i>γ</i>-globulin on this stationary phase was (71.5 ±2.1) mg/g (<i>n</i>=3), which was twice that of a traditional temperature-sensitive affinity chromatography stationary phase SiO<sub>2</sub>-PNIPAM-MEP. The stationary phase was also used to separate and purify immunoglobulin (IgG) in human serum in one step by altering the temperature and ion strength of the mobile phase, resulting in a purity of 97.4%±0.7%. Thus, this new technology has specific selectivity for antibodies, as well as mild and green elution conditions, ultimately resolving the problem of traditional affinity chromatography using acid elution, which can lead to the antibodies aggregation/inactivation. This technology has great application potential for the industrial production of antibody drugs.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719812/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Preparation of a block copolymer-based temperature-responsive affinity chromatography stationary phase for antibody separation and purification].\",\"authors\":\"Dongmei Guo, Yiran Xia, Ur Rahman Mujeeb, Jianzhong Wang, Jiawei Liu, Quan Bai\",\"doi\":\"10.3724/SP.J.1123.2023.09028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Antibodies play an essential role in cancer diagnosis and treatment because of the specificity for target biomolecules and reduction of side effects. However, antibodies separation and purification still face some challenges. Antibody elution from columns using a low-pH aqueous solution leads to aggregation or loss of activity of the antibody drugs. In this paper, a block copolymer-based temperature-responsive affinity chromatography (TRAC) stationary phase, SiO<sub>2</sub>-P[NIPAM-<i>b</i>-4VP]-MEP using the block temperature-responsive copolymer poly(<i>N</i>-isopropylacrylamide-<i>b</i>-4-vinylpyridine) (P[NIPAM-<i>b</i>-4VP]) as the space arms and 4-mercaptoethyl pyridine (MEP) as the ligand was prepared for antibody separation. The TRAC column was tested using bovine serum albumin (BSA) and <i>γ</i>-globulin as model proteins, and the effects of salt concentration in the mobile phase and temperature on their separation were studied in detail. At 40 ℃, the TRAC stationary phase only selectively retained <i>γ</i>-globulin due to the specific affinity interaction between antibodies and the ligand MEP. At 5 ℃, <i>γ</i>-globulin can be eluted from the column with a mass recovery of 92.7% using a Tris-HCl buffer (pH 8.0) solution containing 0.6 mol/L NaCl. The adsorption capacity of <i>γ</i>-globulin on this stationary phase was (71.5 ±2.1) mg/g (<i>n</i>=3), which was twice that of a traditional temperature-sensitive affinity chromatography stationary phase SiO<sub>2</sub>-PNIPAM-MEP. The stationary phase was also used to separate and purify immunoglobulin (IgG) in human serum in one step by altering the temperature and ion strength of the mobile phase, resulting in a purity of 97.4%±0.7%. Thus, this new technology has specific selectivity for antibodies, as well as mild and green elution conditions, ultimately resolving the problem of traditional affinity chromatography using acid elution, which can lead to the antibodies aggregation/inactivation. This technology has great application potential for the industrial production of antibody drugs.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719812/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2023.09028\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2023.09028","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
[Preparation of a block copolymer-based temperature-responsive affinity chromatography stationary phase for antibody separation and purification].
Antibodies play an essential role in cancer diagnosis and treatment because of the specificity for target biomolecules and reduction of side effects. However, antibodies separation and purification still face some challenges. Antibody elution from columns using a low-pH aqueous solution leads to aggregation or loss of activity of the antibody drugs. In this paper, a block copolymer-based temperature-responsive affinity chromatography (TRAC) stationary phase, SiO2-P[NIPAM-b-4VP]-MEP using the block temperature-responsive copolymer poly(N-isopropylacrylamide-b-4-vinylpyridine) (P[NIPAM-b-4VP]) as the space arms and 4-mercaptoethyl pyridine (MEP) as the ligand was prepared for antibody separation. The TRAC column was tested using bovine serum albumin (BSA) and γ-globulin as model proteins, and the effects of salt concentration in the mobile phase and temperature on their separation were studied in detail. At 40 ℃, the TRAC stationary phase only selectively retained γ-globulin due to the specific affinity interaction between antibodies and the ligand MEP. At 5 ℃, γ-globulin can be eluted from the column with a mass recovery of 92.7% using a Tris-HCl buffer (pH 8.0) solution containing 0.6 mol/L NaCl. The adsorption capacity of γ-globulin on this stationary phase was (71.5 ±2.1) mg/g (n=3), which was twice that of a traditional temperature-sensitive affinity chromatography stationary phase SiO2-PNIPAM-MEP. The stationary phase was also used to separate and purify immunoglobulin (IgG) in human serum in one step by altering the temperature and ion strength of the mobile phase, resulting in a purity of 97.4%±0.7%. Thus, this new technology has specific selectivity for antibodies, as well as mild and green elution conditions, ultimately resolving the problem of traditional affinity chromatography using acid elution, which can lead to the antibodies aggregation/inactivation. This technology has great application potential for the industrial production of antibody drugs.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.