Xianli Wang, Qinxiong Rao, Qicai Zhang, Penghui DU, Weiguo Song
{"title":"[多孔过滤净化-超高效液相色谱-串联质谱法测定中华绒螯蟹中的 14 种全氟烷基物质]。","authors":"Xianli Wang, Qinxiong Rao, Qicai Zhang, Penghui DU, Weiguo Song","doi":"10.3724/SP.J.1123.2023.07017","DOIUrl":null,"url":null,"abstract":"<p><p>Perfluoroalkyl substances (PFASs) have become a new food-safety problem. Dietary intake is a major pathway of human exposure to PFASs. Chinese mitten crab (<i>Eriocheir sinensis</i>) is a high-end aquaculture product popular among consumers in China. Conventional extraction methods for PFASs are cumbersome and time consuming, and result in incomplete purification; thus, this technique does not meet the requirements for PFAS detection. Herein, an analytical strategy was established for the rapid detection of 14 PFASs in Chinese mitten crab based on multi-plug filtration cleanup (m-PFC) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The carbon-chain length of the 14 PFASs analyzed in this study ranged from 4 to 14, and they are perfluorobutanoic acid (PFBA), perfluoro-<i>n</i>-pentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluoro-1-butane sulfonic acid (PFBS), perfluoro-1-hexane sulfonic acid (PFHxS), perfluoro-1-octane sulfonic acid (PFOS), and perfluoro-1-decanesulfonate (PFDS). The m-PFC column was prepared using carboxy-based multiwalled carbon nanotubes, and used to reduce the interference of sample impurities. The samples were extracted with 5 mL of 0.1% formic acid aqueous solution, 15 mL of acetonitrile and extraction salt (2 g Na<sub>2</sub>SO<sub>4</sub> and 2 g NaCl). The supernatant (10 mL) was purified using the m-PFC column, concentrated to near dryness under nitrogen, and then redissolved in 1 mL of methanol. Finally, the sample solution was filtered through a 0.22 μm polypropylene syringe filter for UPLC-MS/MS analysis. The target analytes were separated using a Shimadzu Shim-pack G1ST-C18 chromatographic column (100 mm×2.1 mm, 2 μm) using methanol (A) and 5 mmol/L ammonium acetate aqueous solution (B) as the mobile phases via gradient elution. The linear gradient program were as follows: 0-0.5 min, 10%A-35%A; 0.5-3 min, 35%A-60%A; 3-5 min, 60%A-100%A; 5-6.5 min, 100%A; 6.5-7 min, 100%A-10%A. The target analytes were analyzed using negative electrospray ionization in multiple-reaction monitoring mode, and quantitative analysis was performed using the internal standard method. In this study, we optimized the mobile-phase system as well as the extraction solvent, time, volume, and salt. The 14 PFASs exhibited good peak shapes and sensitivities when the 5 mmol/L ammonium acetate solution-methanol system was used as the mobile phase. Compared with acetonitrile or methanol alone, the extraction efficiencies of the 14 PFASs were significantly improved when 5 mL of 0.1% formic acid aqueous solution was added, followed by 15 mL of acetonitrile. The extraction efficiencies of the 14 PFASs did not differ significantly when the extraction time was within 3-15 min. The extraction salt (MgSO<sub>4</sub>, Na<sub>2</sub>SO<sub>4</sub>, NaCl, (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>SO<sub>4</sub>+NaCl) significantly affected the extraction efficiencies of the 14 PFASs. The highest extraction efficiencies of the 14 PFASs, which ranged from 47.9% to 121.9%, were obtained when Na<sub>2</sub>SO<sub>4</sub>+NaCl was used as the extraction salt. Under the optimal experimental conditions, good linearities (<i>R</i><sup>2</sup>=0.998-0.999) were obtained for seven PFASs (PFBS, PFHxA, PFHpA, PFHxS, PFDA, PFDoDA, PFTeDA) at 0.10-100 μg/L, and seven PFASs (PFBA, PFPeA, PFOA, PFOS, PFNA, PFUnDA, PFDS) at 0.50-100 μg/L. The average spiked recoveries for the 14 PFASs in Chinese mitten crabs at three levels ranged from 73.1% to 120%, with relative standard deviations (RSDs) in the range of 1.68%-19.5%(<i>n</i>=6). The limits of detection (LODs) and quantification (LOQs) of the 14 PFASs were in the range of 0.03-0.15 and 0.10-0.50 μg/kg, respectively. The developed method was applied to the analysis of crab samples collected from three farms in Shanghai, and PFASs with total concentrations of 3.52-37.77 μg/kg were detected in all samples. The detection frequencies for PFDA, PFUnDA, PFDoDA, PFTeDA, and PFOS were 100%. PFDA, PFUnDA, PFOS, and PFDoDA were the most abundant congeners, accounting for 31.2%, 30.6%, 15.0%, and 10.9%, respectively, of the 14 PFASs detected. The proposed method is simple, efficient, accurate, and suitable for the rapid analysis of 14 PFASs in Chinese mitten crabs.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719808/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Determination of 14 perfluoroalkyl substances in Chinese mitten crab by multi-plug filtration cleanup coupled with ultra-performance liquid chromatography-tandem mass spectrometry].\",\"authors\":\"Xianli Wang, Qinxiong Rao, Qicai Zhang, Penghui DU, Weiguo Song\",\"doi\":\"10.3724/SP.J.1123.2023.07017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Perfluoroalkyl substances (PFASs) have become a new food-safety problem. Dietary intake is a major pathway of human exposure to PFASs. Chinese mitten crab (<i>Eriocheir sinensis</i>) is a high-end aquaculture product popular among consumers in China. Conventional extraction methods for PFASs are cumbersome and time consuming, and result in incomplete purification; thus, this technique does not meet the requirements for PFAS detection. Herein, an analytical strategy was established for the rapid detection of 14 PFASs in Chinese mitten crab based on multi-plug filtration cleanup (m-PFC) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The carbon-chain length of the 14 PFASs analyzed in this study ranged from 4 to 14, and they are perfluorobutanoic acid (PFBA), perfluoro-<i>n</i>-pentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluoro-1-butane sulfonic acid (PFBS), perfluoro-1-hexane sulfonic acid (PFHxS), perfluoro-1-octane sulfonic acid (PFOS), and perfluoro-1-decanesulfonate (PFDS). The m-PFC column was prepared using carboxy-based multiwalled carbon nanotubes, and used to reduce the interference of sample impurities. The samples were extracted with 5 mL of 0.1% formic acid aqueous solution, 15 mL of acetonitrile and extraction salt (2 g Na<sub>2</sub>SO<sub>4</sub> and 2 g NaCl). The supernatant (10 mL) was purified using the m-PFC column, concentrated to near dryness under nitrogen, and then redissolved in 1 mL of methanol. Finally, the sample solution was filtered through a 0.22 μm polypropylene syringe filter for UPLC-MS/MS analysis. The target analytes were separated using a Shimadzu Shim-pack G1ST-C18 chromatographic column (100 mm×2.1 mm, 2 μm) using methanol (A) and 5 mmol/L ammonium acetate aqueous solution (B) as the mobile phases via gradient elution. The linear gradient program were as follows: 0-0.5 min, 10%A-35%A; 0.5-3 min, 35%A-60%A; 3-5 min, 60%A-100%A; 5-6.5 min, 100%A; 6.5-7 min, 100%A-10%A. The target analytes were analyzed using negative electrospray ionization in multiple-reaction monitoring mode, and quantitative analysis was performed using the internal standard method. In this study, we optimized the mobile-phase system as well as the extraction solvent, time, volume, and salt. The 14 PFASs exhibited good peak shapes and sensitivities when the 5 mmol/L ammonium acetate solution-methanol system was used as the mobile phase. Compared with acetonitrile or methanol alone, the extraction efficiencies of the 14 PFASs were significantly improved when 5 mL of 0.1% formic acid aqueous solution was added, followed by 15 mL of acetonitrile. The extraction efficiencies of the 14 PFASs did not differ significantly when the extraction time was within 3-15 min. The extraction salt (MgSO<sub>4</sub>, Na<sub>2</sub>SO<sub>4</sub>, NaCl, (NH<sub>4</sub>)<sub>2</sub>SO<sub>4</sub>, and Na<sub>2</sub>SO<sub>4</sub>+NaCl) significantly affected the extraction efficiencies of the 14 PFASs. The highest extraction efficiencies of the 14 PFASs, which ranged from 47.9% to 121.9%, were obtained when Na<sub>2</sub>SO<sub>4</sub>+NaCl was used as the extraction salt. Under the optimal experimental conditions, good linearities (<i>R</i><sup>2</sup>=0.998-0.999) were obtained for seven PFASs (PFBS, PFHxA, PFHpA, PFHxS, PFDA, PFDoDA, PFTeDA) at 0.10-100 μg/L, and seven PFASs (PFBA, PFPeA, PFOA, PFOS, PFNA, PFUnDA, PFDS) at 0.50-100 μg/L. The average spiked recoveries for the 14 PFASs in Chinese mitten crabs at three levels ranged from 73.1% to 120%, with relative standard deviations (RSDs) in the range of 1.68%-19.5%(<i>n</i>=6). The limits of detection (LODs) and quantification (LOQs) of the 14 PFASs were in the range of 0.03-0.15 and 0.10-0.50 μg/kg, respectively. The developed method was applied to the analysis of crab samples collected from three farms in Shanghai, and PFASs with total concentrations of 3.52-37.77 μg/kg were detected in all samples. The detection frequencies for PFDA, PFUnDA, PFDoDA, PFTeDA, and PFOS were 100%. PFDA, PFUnDA, PFOS, and PFDoDA were the most abundant congeners, accounting for 31.2%, 30.6%, 15.0%, and 10.9%, respectively, of the 14 PFASs detected. The proposed method is simple, efficient, accurate, and suitable for the rapid analysis of 14 PFASs in Chinese mitten crabs.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10719808/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2023.07017\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2023.07017","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
[Determination of 14 perfluoroalkyl substances in Chinese mitten crab by multi-plug filtration cleanup coupled with ultra-performance liquid chromatography-tandem mass spectrometry].
Perfluoroalkyl substances (PFASs) have become a new food-safety problem. Dietary intake is a major pathway of human exposure to PFASs. Chinese mitten crab (Eriocheir sinensis) is a high-end aquaculture product popular among consumers in China. Conventional extraction methods for PFASs are cumbersome and time consuming, and result in incomplete purification; thus, this technique does not meet the requirements for PFAS detection. Herein, an analytical strategy was established for the rapid detection of 14 PFASs in Chinese mitten crab based on multi-plug filtration cleanup (m-PFC) and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The carbon-chain length of the 14 PFASs analyzed in this study ranged from 4 to 14, and they are perfluorobutanoic acid (PFBA), perfluoro-n-pentanoic acid (PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorooctanoic acid (PFOA), perfluorononanoic acid (PFNA), perfluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), perfluorotetradecanoic acid (PFTeDA), perfluoro-1-butane sulfonic acid (PFBS), perfluoro-1-hexane sulfonic acid (PFHxS), perfluoro-1-octane sulfonic acid (PFOS), and perfluoro-1-decanesulfonate (PFDS). The m-PFC column was prepared using carboxy-based multiwalled carbon nanotubes, and used to reduce the interference of sample impurities. The samples were extracted with 5 mL of 0.1% formic acid aqueous solution, 15 mL of acetonitrile and extraction salt (2 g Na2SO4 and 2 g NaCl). The supernatant (10 mL) was purified using the m-PFC column, concentrated to near dryness under nitrogen, and then redissolved in 1 mL of methanol. Finally, the sample solution was filtered through a 0.22 μm polypropylene syringe filter for UPLC-MS/MS analysis. The target analytes were separated using a Shimadzu Shim-pack G1ST-C18 chromatographic column (100 mm×2.1 mm, 2 μm) using methanol (A) and 5 mmol/L ammonium acetate aqueous solution (B) as the mobile phases via gradient elution. The linear gradient program were as follows: 0-0.5 min, 10%A-35%A; 0.5-3 min, 35%A-60%A; 3-5 min, 60%A-100%A; 5-6.5 min, 100%A; 6.5-7 min, 100%A-10%A. The target analytes were analyzed using negative electrospray ionization in multiple-reaction monitoring mode, and quantitative analysis was performed using the internal standard method. In this study, we optimized the mobile-phase system as well as the extraction solvent, time, volume, and salt. The 14 PFASs exhibited good peak shapes and sensitivities when the 5 mmol/L ammonium acetate solution-methanol system was used as the mobile phase. Compared with acetonitrile or methanol alone, the extraction efficiencies of the 14 PFASs were significantly improved when 5 mL of 0.1% formic acid aqueous solution was added, followed by 15 mL of acetonitrile. The extraction efficiencies of the 14 PFASs did not differ significantly when the extraction time was within 3-15 min. The extraction salt (MgSO4, Na2SO4, NaCl, (NH4)2SO4, and Na2SO4+NaCl) significantly affected the extraction efficiencies of the 14 PFASs. The highest extraction efficiencies of the 14 PFASs, which ranged from 47.9% to 121.9%, were obtained when Na2SO4+NaCl was used as the extraction salt. Under the optimal experimental conditions, good linearities (R2=0.998-0.999) were obtained for seven PFASs (PFBS, PFHxA, PFHpA, PFHxS, PFDA, PFDoDA, PFTeDA) at 0.10-100 μg/L, and seven PFASs (PFBA, PFPeA, PFOA, PFOS, PFNA, PFUnDA, PFDS) at 0.50-100 μg/L. The average spiked recoveries for the 14 PFASs in Chinese mitten crabs at three levels ranged from 73.1% to 120%, with relative standard deviations (RSDs) in the range of 1.68%-19.5%(n=6). The limits of detection (LODs) and quantification (LOQs) of the 14 PFASs were in the range of 0.03-0.15 and 0.10-0.50 μg/kg, respectively. The developed method was applied to the analysis of crab samples collected from three farms in Shanghai, and PFASs with total concentrations of 3.52-37.77 μg/kg were detected in all samples. The detection frequencies for PFDA, PFUnDA, PFDoDA, PFTeDA, and PFOS were 100%. PFDA, PFUnDA, PFOS, and PFDoDA were the most abundant congeners, accounting for 31.2%, 30.6%, 15.0%, and 10.9%, respectively, of the 14 PFASs detected. The proposed method is simple, efficient, accurate, and suitable for the rapid analysis of 14 PFASs in Chinese mitten crabs.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.