COOMET 用于辐射防护和放射诊断的 X 射线质量空气开尔玛国家标准的地区比较 (COOMET.RI(I)-S3)

IF 2.1 3区 工程技术 Q2 INSTRUMENTS & INSTRUMENTATION
Siarhei Saroka, Gonzalo Walwyn Salas, Efimia Luchian, Ludwig Büermann, Alexandr Oborin, Simon Sukhishvili, Paula Toroi, Elmar Shahverdiyev, Andrey Orobinski, Nasir Mamyrbek
{"title":"COOMET 用于辐射防护和放射诊断的 X 射线质量空气开尔玛国家标准的地区比较 (COOMET.RI(I)-S3)","authors":"Siarhei Saroka, Gonzalo Walwyn Salas, Efimia Luchian, Ludwig Büermann, Alexandr Oborin, Simon Sukhishvili, Paula Toroi, Elmar Shahverdiyev, Andrey Orobinski, Nasir Mamyrbek","doi":"10.1088/0026-1394/60/1a/06025","DOIUrl":null,"url":null,"abstract":"<title>Main text</title>The results of the COOMET supplementary comparison of the national measurement standards of air kerma for x-radiation qualities used for radiation protection and diagnostic radiology are presented. Nine National Metrology Institutes from the COOMET organization and the International Atomic Energy Agency participated in this COOMET project no.641. The BelGIM acted as a pilot laboratory. The comparison reference value (CRV) was obtained as the mean result of the PTB and the VNIIM. Almost all participants obtained valid results which were consistent within the relative standard uncertainties of the comparison ranging from 0.28% to 2.6%. Some participants had unacceptable results.To reach the main text of this paper, click on <ext-link xlink:href=\"https://www.bipm.org/documents/d/guest/coomet-ri-i-s3\" xlink:type=\"simple\">Final Report</ext-link>. Note that this text is that which appears in Appendix B of the BIPM key comparison database <ext-link xlink:href=\"https://www.bipm.org/kcdb/\" xlink:type=\"simple\">https://www.bipm.org/kcdb/</ext-link>.The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":"8 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2023-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"COOMET regional comparison of the national standards of air kerma for x-radiation qualities used for radiation protection and diagnostic radiology (COOMET.RI(I)-S3)\",\"authors\":\"Siarhei Saroka, Gonzalo Walwyn Salas, Efimia Luchian, Ludwig Büermann, Alexandr Oborin, Simon Sukhishvili, Paula Toroi, Elmar Shahverdiyev, Andrey Orobinski, Nasir Mamyrbek\",\"doi\":\"10.1088/0026-1394/60/1a/06025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<title>Main text</title>The results of the COOMET supplementary comparison of the national measurement standards of air kerma for x-radiation qualities used for radiation protection and diagnostic radiology are presented. Nine National Metrology Institutes from the COOMET organization and the International Atomic Energy Agency participated in this COOMET project no.641. The BelGIM acted as a pilot laboratory. The comparison reference value (CRV) was obtained as the mean result of the PTB and the VNIIM. Almost all participants obtained valid results which were consistent within the relative standard uncertainties of the comparison ranging from 0.28% to 2.6%. Some participants had unacceptable results.To reach the main text of this paper, click on <ext-link xlink:href=\\\"https://www.bipm.org/documents/d/guest/coomet-ri-i-s3\\\" xlink:type=\\\"simple\\\">Final Report</ext-link>. Note that this text is that which appears in Appendix B of the BIPM key comparison database <ext-link xlink:href=\\\"https://www.bipm.org/kcdb/\\\" xlink:type=\\\"simple\\\">https://www.bipm.org/kcdb/</ext-link>.The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).\",\"PeriodicalId\":18444,\"journal\":{\"name\":\"Metrologia\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrologia\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/0026-1394/60/1a/06025\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/0026-1394/60/1a/06025","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

正文介绍了 COOMET 对用于辐射防护和放射诊断的 X 射线质量的空气热玛国家测量标准进行补充比对的结果。来自 COOMET 组织和国际原子能机构的九个国家计量机构参加了 COOMET 第 641 号项目。BelGIM 作为试点实验室。比对参考值(CRV)是根据 PTB 和 VNIIM 的平均结果得出的。几乎所有参与者都获得了有效的结果,这些结果在 0.28%至 2.6%的比较相对标准不确定度范围内保持一致。一些参与者的结果不可接受。要阅读本文正文,请点击最终报告。请注意,本文是 BIPM 关键比对数据库附录 B 中的内容 https://www.bipm.org/kcdb/.The 根据 CIPM 互认安排 (CIPM MRA) 的规定,最终报告已经过同行评审,并获准由 CCRI 出版。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
COOMET regional comparison of the national standards of air kerma for x-radiation qualities used for radiation protection and diagnostic radiology (COOMET.RI(I)-S3)
Main textThe results of the COOMET supplementary comparison of the national measurement standards of air kerma for x-radiation qualities used for radiation protection and diagnostic radiology are presented. Nine National Metrology Institutes from the COOMET organization and the International Atomic Energy Agency participated in this COOMET project no.641. The BelGIM acted as a pilot laboratory. The comparison reference value (CRV) was obtained as the mean result of the PTB and the VNIIM. Almost all participants obtained valid results which were consistent within the relative standard uncertainties of the comparison ranging from 0.28% to 2.6%. Some participants had unacceptable results.To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metrologia
Metrologia 工程技术-物理:应用
CiteScore
2.80
自引率
25.00%
发文量
137
审稿时长
12 months
期刊介绍: Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them. The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics. In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信