Seungjin Lee, Seung Hyeon Reo, Seokjoon Kim, Seokhwan Kim, Eun Sung Lee, Byung Seok Cha, Jiye Shin, Jinjoo Han, So Min Ahn, Han-Seung Shin, Ki Soo Park
{"title":"基于直接环路介导等温扩增与侧流检测相结合的金黄色葡萄球菌比色检测法","authors":"Seungjin Lee, Seung Hyeon Reo, Seokjoon Kim, Seokhwan Kim, Eun Sung Lee, Byung Seok Cha, Jiye Shin, Jinjoo Han, So Min Ahn, Han-Seung Shin, Ki Soo Park","doi":"10.1007/s13206-023-00130-2","DOIUrl":null,"url":null,"abstract":"<p>In this study, <i>Staphylococcus aureus</i> (<i>S. aureus</i>) was detected using a system that combined direct loop-mediated isothermal amplification (LAMP) and lateral flow assays (LFA). This technology relies on sequence-specific hybridization in LFA; furthermore, it has high specificity and addresses the limitations associated with nonspecific amplification in general colorimetric LAMP. In addition, a direct boiling method was adopted to streamline DNA extraction and enable simple detection. The established technology was used to successfully detect <i>S. aureus</i> at a concentration as low as 10<sup>2</sup> colony-forming unit/mL, without cross-reactivity with other strains. The practical applicability of this technology was demonstrated by analyzing real samples such as beef jerky, cabbage, and eggshell, which were artificially spiked with <i>S. aureus</i>. This developed system may be beneficial with regard to operational simplicity, short analysis time, and high detection performance, which would enable its application in point-of-care settings and as a novel platform for detecting various pathogens.</p>","PeriodicalId":8768,"journal":{"name":"BioChip Journal","volume":null,"pages":null},"PeriodicalIF":5.5000,"publicationDate":"2023-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Colorimetric Detection of Staphylococcus aureus Based on Direct Loop-Mediated Isothermal Amplification in Combination with Lateral Flow Assay\",\"authors\":\"Seungjin Lee, Seung Hyeon Reo, Seokjoon Kim, Seokhwan Kim, Eun Sung Lee, Byung Seok Cha, Jiye Shin, Jinjoo Han, So Min Ahn, Han-Seung Shin, Ki Soo Park\",\"doi\":\"10.1007/s13206-023-00130-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In this study, <i>Staphylococcus aureus</i> (<i>S. aureus</i>) was detected using a system that combined direct loop-mediated isothermal amplification (LAMP) and lateral flow assays (LFA). This technology relies on sequence-specific hybridization in LFA; furthermore, it has high specificity and addresses the limitations associated with nonspecific amplification in general colorimetric LAMP. In addition, a direct boiling method was adopted to streamline DNA extraction and enable simple detection. The established technology was used to successfully detect <i>S. aureus</i> at a concentration as low as 10<sup>2</sup> colony-forming unit/mL, without cross-reactivity with other strains. The practical applicability of this technology was demonstrated by analyzing real samples such as beef jerky, cabbage, and eggshell, which were artificially spiked with <i>S. aureus</i>. This developed system may be beneficial with regard to operational simplicity, short analysis time, and high detection performance, which would enable its application in point-of-care settings and as a novel platform for detecting various pathogens.</p>\",\"PeriodicalId\":8768,\"journal\":{\"name\":\"BioChip Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.5000,\"publicationDate\":\"2023-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BioChip Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s13206-023-00130-2\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioChip Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13206-023-00130-2","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Colorimetric Detection of Staphylococcus aureus Based on Direct Loop-Mediated Isothermal Amplification in Combination with Lateral Flow Assay
In this study, Staphylococcus aureus (S. aureus) was detected using a system that combined direct loop-mediated isothermal amplification (LAMP) and lateral flow assays (LFA). This technology relies on sequence-specific hybridization in LFA; furthermore, it has high specificity and addresses the limitations associated with nonspecific amplification in general colorimetric LAMP. In addition, a direct boiling method was adopted to streamline DNA extraction and enable simple detection. The established technology was used to successfully detect S. aureus at a concentration as low as 102 colony-forming unit/mL, without cross-reactivity with other strains. The practical applicability of this technology was demonstrated by analyzing real samples such as beef jerky, cabbage, and eggshell, which were artificially spiked with S. aureus. This developed system may be beneficial with regard to operational simplicity, short analysis time, and high detection performance, which would enable its application in point-of-care settings and as a novel platform for detecting various pathogens.
期刊介绍:
BioChip Journal publishes original research and reviews in all areas of the biochip technology in the following disciplines, including protein chip, DNA chip, cell chip, lab-on-a-chip, bio-MEMS, biosensor, micro/nano mechanics, microfluidics, high-throughput screening technology, medical science, genomics, proteomics, bioinformatics, medical diagnostics, environmental monitoring and micro/nanotechnology. The Journal is committed to rapid peer review to ensure the publication of highest quality original research and timely news and review articles.