患者自行将凝胶导入阴道以评估深部子宫内膜异位症的体验:试点研究

IF 0.4 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Sonography Pub Date : 2023-12-03 DOI:10.1002/sono.12391
Tracy Truong, N. Kennedy, Vasundhara Kaushik, Jennifer Alphonse, A. Quinton
{"title":"患者自行将凝胶导入阴道以评估深部子宫内膜异位症的体验:试点研究","authors":"Tracy Truong, N. Kennedy, Vasundhara Kaushik, Jennifer Alphonse, A. Quinton","doi":"10.1002/sono.12391","DOIUrl":null,"url":null,"abstract":"When scanning for deep endometriosis a 20 mL syringe is used to insert gel into the vagina for a gel sonovaginography (SVG) examination. This is invasive and can cause discomfort. The aim of this study is to compare participant experience with the self‐administration of 20 mL of gel total using a 10 mL syringe versus 20 mL syringe for participants undergoing a gel SVG ultrasound to assess for any participant discomfort.This study was a quantitative pilot study with 31 participants. Consenting participants were instructed to insert a total of 20 mL of gel divided equally into one 20 mL and one 10 mL syringe, into their own vagina prior to SVG. After the SVG, a questionnaire was provided to determine the level of discomfort experienced.Overall participants found the instructions clear and the insertion of either syringe tolerable. The results demonstrated that 22/31 (71%) of participants had no discomfort inserting the 10 mL syringe. In comparison, 17/31 (55%) reported slight or mild discomfort inserting the 20 mL syringe. The majority of participants preferred inserting one 20 mL syringe rather than two 10 mL syringes.Participants found the gel insertion using either syringe tolerable with most participants finding the 10 mL syringe more comfortable but would overall prefer inserting one 20 mL syringe instead of two 10 mL syringes. Future studies on larger numbers of multicultural participants using variable syringe sizes with varying amounts of gel should be considered.","PeriodicalId":29898,"journal":{"name":"Sonography","volume":"32 3","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Patient experience when self‐introducing gel into the vagina for assessment of deep endometriosis: A pilot study\",\"authors\":\"Tracy Truong, N. Kennedy, Vasundhara Kaushik, Jennifer Alphonse, A. Quinton\",\"doi\":\"10.1002/sono.12391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When scanning for deep endometriosis a 20 mL syringe is used to insert gel into the vagina for a gel sonovaginography (SVG) examination. This is invasive and can cause discomfort. The aim of this study is to compare participant experience with the self‐administration of 20 mL of gel total using a 10 mL syringe versus 20 mL syringe for participants undergoing a gel SVG ultrasound to assess for any participant discomfort.This study was a quantitative pilot study with 31 participants. Consenting participants were instructed to insert a total of 20 mL of gel divided equally into one 20 mL and one 10 mL syringe, into their own vagina prior to SVG. After the SVG, a questionnaire was provided to determine the level of discomfort experienced.Overall participants found the instructions clear and the insertion of either syringe tolerable. The results demonstrated that 22/31 (71%) of participants had no discomfort inserting the 10 mL syringe. In comparison, 17/31 (55%) reported slight or mild discomfort inserting the 20 mL syringe. The majority of participants preferred inserting one 20 mL syringe rather than two 10 mL syringes.Participants found the gel insertion using either syringe tolerable with most participants finding the 10 mL syringe more comfortable but would overall prefer inserting one 20 mL syringe instead of two 10 mL syringes. Future studies on larger numbers of multicultural participants using variable syringe sizes with varying amounts of gel should be considered.\",\"PeriodicalId\":29898,\"journal\":{\"name\":\"Sonography\",\"volume\":\"32 3\",\"pages\":\"\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sonography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/sono.12391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sonography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sono.12391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

当扫描深部子宫内膜异位症时,使用20ml注射器将凝胶插入阴道进行凝胶超声检查(SVG)。这是侵入性的,会引起不适。本研究的目的是比较参与者使用10ml注射器和20ml注射器自行给药20ml凝胶的体验,以评估接受凝胶SVG超声检查的参与者的任何不适。本研究是一项有31名参与者的定量先导研究。同意的参与者被指示在SVG之前将总共20毫升的凝胶平均分成一个20毫升和一个10毫升的注射器插入自己的阴道。在SVG之后,提供了一份问卷来确定所经历的不适程度。总的来说,参与者发现说明很清楚,并且可以接受任何一种注射器的插入。结果显示,22/31(71%)的参与者在插入10ml注射器时没有不适。相比之下,17/31(55%)报告在插入20ml注射器时有轻微或轻度不适。大多数参与者更喜欢插入一个20毫升的注射器而不是两个10毫升的注射器。参与者发现使用两种注射器插入凝胶都是可以忍受的,大多数参与者发现10毫升注射器更舒适,但总体上更喜欢插入一个20毫升注射器而不是两个10毫升注射器。未来的研究应该考虑更多的多元文化参与者使用不同大小的注射器和不同数量的凝胶。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Patient experience when self‐introducing gel into the vagina for assessment of deep endometriosis: A pilot study
When scanning for deep endometriosis a 20 mL syringe is used to insert gel into the vagina for a gel sonovaginography (SVG) examination. This is invasive and can cause discomfort. The aim of this study is to compare participant experience with the self‐administration of 20 mL of gel total using a 10 mL syringe versus 20 mL syringe for participants undergoing a gel SVG ultrasound to assess for any participant discomfort.This study was a quantitative pilot study with 31 participants. Consenting participants were instructed to insert a total of 20 mL of gel divided equally into one 20 mL and one 10 mL syringe, into their own vagina prior to SVG. After the SVG, a questionnaire was provided to determine the level of discomfort experienced.Overall participants found the instructions clear and the insertion of either syringe tolerable. The results demonstrated that 22/31 (71%) of participants had no discomfort inserting the 10 mL syringe. In comparison, 17/31 (55%) reported slight or mild discomfort inserting the 20 mL syringe. The majority of participants preferred inserting one 20 mL syringe rather than two 10 mL syringes.Participants found the gel insertion using either syringe tolerable with most participants finding the 10 mL syringe more comfortable but would overall prefer inserting one 20 mL syringe instead of two 10 mL syringes. Future studies on larger numbers of multicultural participants using variable syringe sizes with varying amounts of gel should be considered.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sonography
Sonography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.80
自引率
0.00%
发文量
44
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信