体外评估三种不同支柱系统的推出粘接强度

Tara Kamal Talib Bajlan, R. Salman
{"title":"体外评估三种不同支柱系统的推出粘接强度","authors":"Tara Kamal Talib Bajlan, R. Salman","doi":"10.56056/amj.2023.223","DOIUrl":null,"url":null,"abstract":"Background and objectives: Intimate adaptation to the canal walls is accomplished by custom-made posts which leave an even thickness of cement layer. Therefore, this study has been conducted for assessing the strength of push-out bond among prefabricated fiber posts, relined fiberglass posts, and zirconium posts using resin cement of self-adhesive and adhesive. The mode of failure was also assessed. Materials and Methods: Sixty uniradicular teeth were endodontically treated. According to the kind of post system and cement utilized (n=10), the specimens were separated randomly into six groups. Zirconium oxide post, customized glass fiber post, and glass fiber post were used. The roots were divided into three discs: apical, middle, and cervical sections. After that, the discs were put through a push-out test, and the fracture mode was examined using a stereomicroscopic loupe. Results: The highest push-out value was recorded for the relined post (8±2.83 MPa), and the lowest was registered with no significant differences for the prefabricated post (7.27±3.76 MPa). There were no significant differences in strength bond across the various posts and root regions (P?.05). Adhesive failure at the dentin-cement interfaces for the prefabricated and relined post was (60, 57) % respectively, and zirconium oxide post was (22%). Conclusions: Relined posts may be a suitable clinical situation as a post material selection with reduced clinical steps. When posts are joined using self-adhesive and adhesive resin cement, the root region has no important influence on the strength of the bond.","PeriodicalId":314832,"journal":{"name":"Advanced medical journal","volume":"77 5","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vitro Evaluation of Push-Out Bond Strength in Three Different Post Systems\",\"authors\":\"Tara Kamal Talib Bajlan, R. Salman\",\"doi\":\"10.56056/amj.2023.223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and objectives: Intimate adaptation to the canal walls is accomplished by custom-made posts which leave an even thickness of cement layer. Therefore, this study has been conducted for assessing the strength of push-out bond among prefabricated fiber posts, relined fiberglass posts, and zirconium posts using resin cement of self-adhesive and adhesive. The mode of failure was also assessed. Materials and Methods: Sixty uniradicular teeth were endodontically treated. According to the kind of post system and cement utilized (n=10), the specimens were separated randomly into six groups. Zirconium oxide post, customized glass fiber post, and glass fiber post were used. The roots were divided into three discs: apical, middle, and cervical sections. After that, the discs were put through a push-out test, and the fracture mode was examined using a stereomicroscopic loupe. Results: The highest push-out value was recorded for the relined post (8±2.83 MPa), and the lowest was registered with no significant differences for the prefabricated post (7.27±3.76 MPa). There were no significant differences in strength bond across the various posts and root regions (P?.05). Adhesive failure at the dentin-cement interfaces for the prefabricated and relined post was (60, 57) % respectively, and zirconium oxide post was (22%). Conclusions: Relined posts may be a suitable clinical situation as a post material selection with reduced clinical steps. When posts are joined using self-adhesive and adhesive resin cement, the root region has no important influence on the strength of the bond.\",\"PeriodicalId\":314832,\"journal\":{\"name\":\"Advanced medical journal\",\"volume\":\"77 5\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced medical journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56056/amj.2023.223\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced medical journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56056/amj.2023.223","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景和目的:通过定制的柱子来完成与运河壁的亲密适应,这些柱子留下了均匀厚度的水泥层。因此,本研究采用自粘树脂水泥和胶粘剂对预制纤维桩、内衬玻璃纤维桩和锆桩的推出粘结强度进行了评估。对失效模式也进行了评估。材料与方法:对60颗单根牙进行根管治疗。根据桩系类型和所用水泥(n=10),将试件随机分为6组。采用氧化锆柱、定制化玻璃纤维柱和玻璃纤维柱。根被分成三个椎间盘:根尖节、中间节和颈节。之后,将椎间盘进行推出测试,并使用立体显微镜检查骨折模式。结果:有线桩的顶出值最高(8±2.83 MPa),预制桩的顶出值最低(7.27±3.76 MPa),两者差异无统计学意义。不同根区和不同桩区的强度结合无显著差异(P? 0.05)。预制桩和内衬桩在牙本质-水泥界面的粘结破坏率分别为(60,57)%,氧化锆桩为(22%)%。结论:作为一种减少临床步骤的岗位材料选择,线型岗位可能是一种合适的临床情况。当采用不干胶和粘接树脂水泥进行桩的连接时,根区对粘结强度没有重要影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
In Vitro Evaluation of Push-Out Bond Strength in Three Different Post Systems
Background and objectives: Intimate adaptation to the canal walls is accomplished by custom-made posts which leave an even thickness of cement layer. Therefore, this study has been conducted for assessing the strength of push-out bond among prefabricated fiber posts, relined fiberglass posts, and zirconium posts using resin cement of self-adhesive and adhesive. The mode of failure was also assessed. Materials and Methods: Sixty uniradicular teeth were endodontically treated. According to the kind of post system and cement utilized (n=10), the specimens were separated randomly into six groups. Zirconium oxide post, customized glass fiber post, and glass fiber post were used. The roots were divided into three discs: apical, middle, and cervical sections. After that, the discs were put through a push-out test, and the fracture mode was examined using a stereomicroscopic loupe. Results: The highest push-out value was recorded for the relined post (8±2.83 MPa), and the lowest was registered with no significant differences for the prefabricated post (7.27±3.76 MPa). There were no significant differences in strength bond across the various posts and root regions (P?.05). Adhesive failure at the dentin-cement interfaces for the prefabricated and relined post was (60, 57) % respectively, and zirconium oxide post was (22%). Conclusions: Relined posts may be a suitable clinical situation as a post material selection with reduced clinical steps. When posts are joined using self-adhesive and adhesive resin cement, the root region has no important influence on the strength of the bond.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信