{"title":"测量压电锥尖孔压系统饱和度的新方法","authors":"I. Rocchi, M. Marcolongo, L. Tonni, G. Gottardi","doi":"10.1680/jgele.23.00034","DOIUrl":null,"url":null,"abstract":"Uncertainty in the measurement of the cone penetration test with pore-water pressure measurement (i.e. piezocone testing CPTU) can be caused by an equipment malfunction, poor calibration and maintenance of sensors, but also by a lack of saturation of the piezocone. The standards allow for many different options in terms of filters, saturation fluids and methodologies. The novel device described herein aims at measuring in a very simple manner the degree of saturation of the piezocone prior to testing. Because the quality of pore-water pressure measurements can currently only be assessed <i>a posteriori</i> – that is, after the test has been completed, or at best while testing, the methodology proposed herein has the potential to provide quality benchmarks for CPTU. The tool measures a parameter inspired by the well-established Skempton coefficient <i>B</i>, which is routinely used to estimate the sample saturation prior to laboratory testing. Furthermore, by performing the same measurement after a CPTU test, it is possible to assess whether saturation was lost during cone penetration. The paper describes a set of preliminary results that show a clear correlation between the saturation degree of filters and/or of the overall pore-pressure measurement system and the <i>B</i> parameter proposed, thus providing a proof of concept in laboratory settings.","PeriodicalId":501470,"journal":{"name":"Géotechnique Letters","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel procedure for measuring the saturation of the pore-pressure system in piezocone tips\",\"authors\":\"I. Rocchi, M. Marcolongo, L. Tonni, G. Gottardi\",\"doi\":\"10.1680/jgele.23.00034\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Uncertainty in the measurement of the cone penetration test with pore-water pressure measurement (i.e. piezocone testing CPTU) can be caused by an equipment malfunction, poor calibration and maintenance of sensors, but also by a lack of saturation of the piezocone. The standards allow for many different options in terms of filters, saturation fluids and methodologies. The novel device described herein aims at measuring in a very simple manner the degree of saturation of the piezocone prior to testing. Because the quality of pore-water pressure measurements can currently only be assessed <i>a posteriori</i> – that is, after the test has been completed, or at best while testing, the methodology proposed herein has the potential to provide quality benchmarks for CPTU. The tool measures a parameter inspired by the well-established Skempton coefficient <i>B</i>, which is routinely used to estimate the sample saturation prior to laboratory testing. Furthermore, by performing the same measurement after a CPTU test, it is possible to assess whether saturation was lost during cone penetration. The paper describes a set of preliminary results that show a clear correlation between the saturation degree of filters and/or of the overall pore-pressure measurement system and the <i>B</i> parameter proposed, thus providing a proof of concept in laboratory settings.\",\"PeriodicalId\":501470,\"journal\":{\"name\":\"Géotechnique Letters\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Géotechnique Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1680/jgele.23.00034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Géotechnique Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1680/jgele.23.00034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Novel procedure for measuring the saturation of the pore-pressure system in piezocone tips
Uncertainty in the measurement of the cone penetration test with pore-water pressure measurement (i.e. piezocone testing CPTU) can be caused by an equipment malfunction, poor calibration and maintenance of sensors, but also by a lack of saturation of the piezocone. The standards allow for many different options in terms of filters, saturation fluids and methodologies. The novel device described herein aims at measuring in a very simple manner the degree of saturation of the piezocone prior to testing. Because the quality of pore-water pressure measurements can currently only be assessed a posteriori – that is, after the test has been completed, or at best while testing, the methodology proposed herein has the potential to provide quality benchmarks for CPTU. The tool measures a parameter inspired by the well-established Skempton coefficient B, which is routinely used to estimate the sample saturation prior to laboratory testing. Furthermore, by performing the same measurement after a CPTU test, it is possible to assess whether saturation was lost during cone penetration. The paper describes a set of preliminary results that show a clear correlation between the saturation degree of filters and/or of the overall pore-pressure measurement system and the B parameter proposed, thus providing a proof of concept in laboratory settings.