Dimitrios A Chatzelas, Apostolos G Pitoulias, Georgios V Tsamourlidis, Theodosia N Zampaka, Anastasios G Potouridis, Maria D Tachtsi, Georgios A Pitoulias
{"title":"利用Altura支架在血管内修复Nellix内移植物近端封闭区失败一例报告及文献复习。","authors":"Dimitrios A Chatzelas, Apostolos G Pitoulias, Georgios V Tsamourlidis, Theodosia N Zampaka, Anastasios G Potouridis, Maria D Tachtsi, Georgios A Pitoulias","doi":"10.5758/vsi.230076","DOIUrl":null,"url":null,"abstract":"<p><p>Endovascular aortic aneurysm sealing (EVAS) with the Nellix endograft was initially considered a groundbreaking and acceptable alternative to conventional endovascular aortic aneurysm repair, with encouraging initial results. However, long-term follow-up has revealed a high incidence of endograft-related complications, such as caudal migration and type Ia endoleaks, indicating the need for reintervention. Managing failed EVAS remains challenging and is an ongoing topic of discussion, especially for high-risk patients. We describe a 70-year-old female who initially underwent EVAS with a Nellix endograft and presented after 5 years of follow-up with caudal endograft migration and a type Ia endoleak. The patient was treated with endovascular implantation of an Altura stent-graft, a relatively new low-profile device with a similar double stent configuration. Device migration and endoleaks were undetectable at 12 months of follow-up, suggesting that the Altura might offer a safe and efficient approach in cases of Nellix proximal failure.</p>","PeriodicalId":52311,"journal":{"name":"Vascular Specialist International","volume":"39 ","pages":"39"},"PeriodicalIF":0.8000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10694563/pdf/","citationCount":"0","resultStr":"{\"title\":\"Endovascular Repair of a Failed Nellix Endograft Proximal Sealing Zone Using the Altura Stent-Graft: A Case Report and Literature Review.\",\"authors\":\"Dimitrios A Chatzelas, Apostolos G Pitoulias, Georgios V Tsamourlidis, Theodosia N Zampaka, Anastasios G Potouridis, Maria D Tachtsi, Georgios A Pitoulias\",\"doi\":\"10.5758/vsi.230076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Endovascular aortic aneurysm sealing (EVAS) with the Nellix endograft was initially considered a groundbreaking and acceptable alternative to conventional endovascular aortic aneurysm repair, with encouraging initial results. However, long-term follow-up has revealed a high incidence of endograft-related complications, such as caudal migration and type Ia endoleaks, indicating the need for reintervention. Managing failed EVAS remains challenging and is an ongoing topic of discussion, especially for high-risk patients. We describe a 70-year-old female who initially underwent EVAS with a Nellix endograft and presented after 5 years of follow-up with caudal endograft migration and a type Ia endoleak. The patient was treated with endovascular implantation of an Altura stent-graft, a relatively new low-profile device with a similar double stent configuration. Device migration and endoleaks were undetectable at 12 months of follow-up, suggesting that the Altura might offer a safe and efficient approach in cases of Nellix proximal failure.</p>\",\"PeriodicalId\":52311,\"journal\":{\"name\":\"Vascular Specialist International\",\"volume\":\"39 \",\"pages\":\"39\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10694563/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vascular Specialist International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5758/vsi.230076\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vascular Specialist International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5758/vsi.230076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Endovascular Repair of a Failed Nellix Endograft Proximal Sealing Zone Using the Altura Stent-Graft: A Case Report and Literature Review.
Endovascular aortic aneurysm sealing (EVAS) with the Nellix endograft was initially considered a groundbreaking and acceptable alternative to conventional endovascular aortic aneurysm repair, with encouraging initial results. However, long-term follow-up has revealed a high incidence of endograft-related complications, such as caudal migration and type Ia endoleaks, indicating the need for reintervention. Managing failed EVAS remains challenging and is an ongoing topic of discussion, especially for high-risk patients. We describe a 70-year-old female who initially underwent EVAS with a Nellix endograft and presented after 5 years of follow-up with caudal endograft migration and a type Ia endoleak. The patient was treated with endovascular implantation of an Altura stent-graft, a relatively new low-profile device with a similar double stent configuration. Device migration and endoleaks were undetectable at 12 months of follow-up, suggesting that the Altura might offer a safe and efficient approach in cases of Nellix proximal failure.