{"title":"无导联起搏器植入后捕获阈值的速率依赖性升高。","authors":"Makoto Sano, Naoyuki Takahashi, Yutaro Kaneko, Taro Narumi, Yoshihisa Naruse, Yuichiro Maekawa","doi":"10.1111/pace.14884","DOIUrl":null,"url":null,"abstract":"<p><p>The procedural success in the implantation of cardiac electric devices depends on both the implanted position and the electric performance. The capture threshold and the pacing output affect the estimated battery longevity. In a case with a high capture threshold, recapture and reimplantation of a leadless pacemaker are commonly recommended. We experienced a case with the rate-dependent elevation of the capture threshold following the implantation of a leadless pacemaker. The recognition of the rate-dependency of the capture threshold and the acceptable programming could avoid the unnecessary recapture and reimplantation of that, avoiding the increase of procedural risks.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rate-dependent elevation of the capture threshold after implantation of a leadless pacemaker.\",\"authors\":\"Makoto Sano, Naoyuki Takahashi, Yutaro Kaneko, Taro Narumi, Yoshihisa Naruse, Yuichiro Maekawa\",\"doi\":\"10.1111/pace.14884\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The procedural success in the implantation of cardiac electric devices depends on both the implanted position and the electric performance. The capture threshold and the pacing output affect the estimated battery longevity. In a case with a high capture threshold, recapture and reimplantation of a leadless pacemaker are commonly recommended. We experienced a case with the rate-dependent elevation of the capture threshold following the implantation of a leadless pacemaker. The recognition of the rate-dependency of the capture threshold and the acceptable programming could avoid the unnecessary recapture and reimplantation of that, avoiding the increase of procedural risks.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.14884\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.14884","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Rate-dependent elevation of the capture threshold after implantation of a leadless pacemaker.
The procedural success in the implantation of cardiac electric devices depends on both the implanted position and the electric performance. The capture threshold and the pacing output affect the estimated battery longevity. In a case with a high capture threshold, recapture and reimplantation of a leadless pacemaker are commonly recommended. We experienced a case with the rate-dependent elevation of the capture threshold following the implantation of a leadless pacemaker. The recognition of the rate-dependency of the capture threshold and the acceptable programming could avoid the unnecessary recapture and reimplantation of that, avoiding the increase of procedural risks.
期刊介绍:
Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.