[食管酸暴露在单个数字:pH曲线下的面积]。

Chirurgie pediatrique Pub Date : 1989-01-01
M A Izquierdo, J A Tovar, I Eizaguirre
{"title":"[食管酸暴露在单个数字:pH曲线下的面积]。","authors":"M A Izquierdo,&nbsp;J A Tovar,&nbsp;I Eizaguirre","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Current interpretation of pH-metering tracings takes into account several variables which indirectly reflect how many times and for how long time pH falls below a threshold value and how efficient is acid clearance. In this investigation we have tested the hypothesis that area under pH curve summarizes all the former values in one single figure. We have compared the four classical pH-metering variables (percentage of time under pH 4, number of GER episodes, number of those lasting more than 5 minutes and duration of the longer episode) and the area under curve between a group of refluxing children (n = 50) and a control group (n = 20). A value of 4% time under pH 4 was selected as \"gold standard\" for separation of both groups. We have figured out sensitivity, specificity and accuracy for all values of each parameter and, by means of ROC (Receiver Operating Characteristic) method, we have determined their performance and the optimum threshold value. Our results demonstrate that area under curve is at least as performant as percentage of time below pH 4, and probably better because it reflects, in addition, the depth of pH falls and the clearance. Taking into consideration that its measurement can be done automatically, we suggest that it should be included in the currently available software for computerized pH reading.</p>","PeriodicalId":75703,"journal":{"name":"Chirurgie pediatrique","volume":"30 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Esophageal acid exposure in a single number: the area under the pH curve].\",\"authors\":\"M A Izquierdo,&nbsp;J A Tovar,&nbsp;I Eizaguirre\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Current interpretation of pH-metering tracings takes into account several variables which indirectly reflect how many times and for how long time pH falls below a threshold value and how efficient is acid clearance. In this investigation we have tested the hypothesis that area under pH curve summarizes all the former values in one single figure. We have compared the four classical pH-metering variables (percentage of time under pH 4, number of GER episodes, number of those lasting more than 5 minutes and duration of the longer episode) and the area under curve between a group of refluxing children (n = 50) and a control group (n = 20). A value of 4% time under pH 4 was selected as \\\"gold standard\\\" for separation of both groups. We have figured out sensitivity, specificity and accuracy for all values of each parameter and, by means of ROC (Receiver Operating Characteristic) method, we have determined their performance and the optimum threshold value. Our results demonstrate that area under curve is at least as performant as percentage of time below pH 4, and probably better because it reflects, in addition, the depth of pH falls and the clearance. Taking into consideration that its measurement can be done automatically, we suggest that it should be included in the currently available software for computerized pH reading.</p>\",\"PeriodicalId\":75703,\"journal\":{\"name\":\"Chirurgie pediatrique\",\"volume\":\"30 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chirurgie pediatrique\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chirurgie pediatrique","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前对pH计量示踪的解释考虑了几个变量,这些变量间接反映了pH值低于阈值的次数和时间,以及酸清除的效率。在本研究中,我们检验了一个假设,即pH曲线下的面积在一个图中总结了所有以前的值。我们比较了四种经典的pH测量变量(pH值低于4的时间百分比、GER发作次数、持续时间超过5分钟的次数和较长发作时间的持续时间)以及反流儿童组(n = 50)和对照组(n = 20)的曲线下面积。在pH值为4的条件下,选择4%的时间作为两组分离的“金标准”。我们计算出了各参数各值的灵敏度、特异性和准确性,并通过ROC (Receiver Operating Characteristic)方法确定了它们的性能和最佳阈值。我们的研究结果表明,曲线下面积至少与pH值低于4的时间百分比相同,而且可能更好,因为它还反映了pH值下降的深度和间隙。考虑到它的测量可以自动完成,我们建议它应该包含在目前可用的计算机pH读数软件中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Esophageal acid exposure in a single number: the area under the pH curve].

Current interpretation of pH-metering tracings takes into account several variables which indirectly reflect how many times and for how long time pH falls below a threshold value and how efficient is acid clearance. In this investigation we have tested the hypothesis that area under pH curve summarizes all the former values in one single figure. We have compared the four classical pH-metering variables (percentage of time under pH 4, number of GER episodes, number of those lasting more than 5 minutes and duration of the longer episode) and the area under curve between a group of refluxing children (n = 50) and a control group (n = 20). A value of 4% time under pH 4 was selected as "gold standard" for separation of both groups. We have figured out sensitivity, specificity and accuracy for all values of each parameter and, by means of ROC (Receiver Operating Characteristic) method, we have determined their performance and the optimum threshold value. Our results demonstrate that area under curve is at least as performant as percentage of time below pH 4, and probably better because it reflects, in addition, the depth of pH falls and the clearance. Taking into consideration that its measurement can be done automatically, we suggest that it should be included in the currently available software for computerized pH reading.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信