{"title":"流量校准系统采用全回转导向阀","authors":"Paweł Kóscielniak, Małgorzata Herman, Joanna Janiszewska","doi":"10.1002/(SICI)1098-2728(1999)11:2<111::AID-LRA7>3.0.CO;2-%23","DOIUrl":null,"url":null,"abstract":"<p>The flow system with fully rotary valve (FRV) operated as a directive valve has been designed and applied for calibration purposes. The role of the FRV was to create the set of standard solutions of compositions desired by directing and merging the streams of a single initial standard solution inserted into a flow manifold. The idea is presented of how different numbers of standards with the analyte concentrations distributed variously along a calibration line are possible to be prepared. It has been experimentally revealed that the system developed allows one to perform the calibration procedure with low consumption of time, work, and reagents, providing accurate and precise analytical results. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 111–119, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 2","pages":"111-119"},"PeriodicalIF":0.0000,"publicationDate":"1999-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Flow calibration system with the use of fully rotary directive valve\",\"authors\":\"Paweł Kóscielniak, Małgorzata Herman, Joanna Janiszewska\",\"doi\":\"10.1002/(SICI)1098-2728(1999)11:2<111::AID-LRA7>3.0.CO;2-%23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The flow system with fully rotary valve (FRV) operated as a directive valve has been designed and applied for calibration purposes. The role of the FRV was to create the set of standard solutions of compositions desired by directing and merging the streams of a single initial standard solution inserted into a flow manifold. The idea is presented of how different numbers of standards with the analyte concentrations distributed variously along a calibration line are possible to be prepared. It has been experimentally revealed that the system developed allows one to perform the calibration procedure with low consumption of time, work, and reagents, providing accurate and precise analytical results. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 111–119, 1999</p>\",\"PeriodicalId\":100863,\"journal\":{\"name\":\"Laboratory Robotics and Automation\",\"volume\":\"11 2\",\"pages\":\"111-119\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A2%3C111%3A%3AAID-LRA7%3E3.0.CO%3B2-%23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A2%3C111%3A%3AAID-LRA7%3E3.0.CO%3B2-%23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0