{"title":"希姆拉市惠普政府牙科学院牙科单位水管的微生物污染","authors":"Shailee Fotedar ,&nbsp;Sunite Ganju","doi":"10.1016/j.sjdr.2014.11.002","DOIUrl":null,"url":null,"abstract":"<div><p><em>Aim</em>: To determine the microbial quality of water from DUWLs and also to determine the efficacy of flushing on reducing its microbial count in Himachal Pradesh Government Dental College, Shimla.</p><p><em>Method</em>: Samples were collected from all the dental chairs in the department of public health dentistry. Ten millilitres of water was collected in a sterile container from air water syringe in the mid afternoon, once before flushing and once after flushing for two minutes. One control sample was also taken from tap in the department. The samples were then sent to department of Microbiology, Indira Gandhi Medical College, Shimla where they were investigated for gram positive and gram negative cocci; gram positive and gram negative bacilli.</p><p><em>Results</em>: No organism was detected in the control sample from tap water. The only organism that was detected was staphylococcus coagulase negative. The mean of staphylococci coagulase negative colony forming units in pre flushing sample was 1460.89 and in post flushing sample was 1380. The difference between pre flushing and post flushing sample was not statistically significant.</p><p><em>Conclusion</em>: Though the organism present in water was only staphylococci coagulase negative, the level was higher than as recommended by CDC, so appropriate disinfection methods should be used, and the source of staphylococci coagulase negative should be investigated. The flushing did not show any significant difference before and after flushing in the present study.</p></div>","PeriodicalId":101249,"journal":{"name":"The Saudi Journal for Dental Research","volume":"6 2","pages":"Pages 129-132"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.sjdr.2014.11.002","citationCount":"7","resultStr":"{\"title\":\"Microbial contamination of dental unit water lines in H.P. Government Dental College, Shimla\",\"authors\":\"Shailee Fotedar ,&nbsp;Sunite Ganju\",\"doi\":\"10.1016/j.sjdr.2014.11.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><em>Aim</em>: To determine the microbial quality of water from DUWLs and also to determine the efficacy of flushing on reducing its microbial count in Himachal Pradesh Government Dental College, Shimla.</p><p><em>Method</em>: Samples were collected from all the dental chairs in the department of public health dentistry. Ten millilitres of water was collected in a sterile container from air water syringe in the mid afternoon, once before flushing and once after flushing for two minutes. One control sample was also taken from tap in the department. The samples were then sent to department of Microbiology, Indira Gandhi Medical College, Shimla where they were investigated for gram positive and gram negative cocci; gram positive and gram negative bacilli.</p><p><em>Results</em>: No organism was detected in the control sample from tap water. The only organism that was detected was staphylococcus coagulase negative. The mean of staphylococci coagulase negative colony forming units in pre flushing sample was 1460.89 and in post flushing sample was 1380. The difference between pre flushing and post flushing sample was not statistically significant.</p><p><em>Conclusion</em>: Though the organism present in water was only staphylococci coagulase negative, the level was higher than as recommended by CDC, so appropriate disinfection methods should be used, and the source of staphylococci coagulase negative should be investigated. The flushing did not show any significant difference before and after flushing in the present study.</p></div>\",\"PeriodicalId\":101249,\"journal\":{\"name\":\"The Saudi Journal for Dental Research\",\"volume\":\"6 2\",\"pages\":\"Pages 129-132\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.sjdr.2014.11.002\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Saudi Journal for Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352003514000458\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Saudi Journal for Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352003514000458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

目的:确定喜马偕尔邦西姆拉政府牙科学院DUWLs水的微生物质量,并确定冲洗对减少其微生物数量的效果。方法:采集口腔卫生科所有牙椅标本。下午三点左右,从空气水注射器中抽取10毫升水,装在无菌容器中,冲洗前一次,冲洗后一次,两分钟。另外还从该署的自来水中抽取了一份对照样本。然后将样本送到西姆拉英迪拉甘地医学院微生物系,在那里对它们进行革兰氏阳性和革兰氏阴性球菌的调查;革兰氏阳性和革兰氏阴性杆菌。结果:自来水对照样品未检出微生物。唯一检出的病原菌为葡萄球菌凝固酶阴性。冲洗前样品葡萄球菌凝固酶阴性菌落形成单位平均值为1460.89个,冲洗后样品葡萄球菌凝固酶阴性菌落形成单位平均值为1380个。冲洗前和冲洗后样本的差异无统计学意义。结论:虽然水体中存在的微生物仅为葡萄球菌凝固酶阴性,但水平高于CDC推荐水平,应采取适当的消毒方法,并调查葡萄球菌凝固酶阴性的来源。在本研究中,冲洗前后的冲洗没有显着差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Microbial contamination of dental unit water lines in H.P. Government Dental College, Shimla

Aim: To determine the microbial quality of water from DUWLs and also to determine the efficacy of flushing on reducing its microbial count in Himachal Pradesh Government Dental College, Shimla.

Method: Samples were collected from all the dental chairs in the department of public health dentistry. Ten millilitres of water was collected in a sterile container from air water syringe in the mid afternoon, once before flushing and once after flushing for two minutes. One control sample was also taken from tap in the department. The samples were then sent to department of Microbiology, Indira Gandhi Medical College, Shimla where they were investigated for gram positive and gram negative cocci; gram positive and gram negative bacilli.

Results: No organism was detected in the control sample from tap water. The only organism that was detected was staphylococcus coagulase negative. The mean of staphylococci coagulase negative colony forming units in pre flushing sample was 1460.89 and in post flushing sample was 1380. The difference between pre flushing and post flushing sample was not statistically significant.

Conclusion: Though the organism present in water was only staphylococci coagulase negative, the level was higher than as recommended by CDC, so appropriate disinfection methods should be used, and the source of staphylococci coagulase negative should be investigated. The flushing did not show any significant difference before and after flushing in the present study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信