基于实弱值弱测量的时延精度估计

Weining Liu, Yisen Wang, Hailu Luo
{"title":"基于实弱值弱测量的时延精度估计","authors":"Weining Liu, Yisen Wang, Hailu Luo","doi":"10.1103/physreva.108.052606","DOIUrl":null,"url":null,"abstract":"In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.","PeriodicalId":20121,"journal":{"name":"Physical Review","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Precision estimation of time delay based on weak measurement with real weak value\",\"authors\":\"Weining Liu, Yisen Wang, Hailu Luo\",\"doi\":\"10.1103/physreva.108.052606\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.\",\"PeriodicalId\":20121,\"journal\":{\"name\":\"Physical Review\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physical Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1103/physreva.108.052606\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1103/physreva.108.052606","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在标准的弱测量中,通常将弱值的虚部构造为特定的选前或选后状态,使频域指针产生较大的偏移。本文证明了在使用广谱光源时,纯实弱值也会引起频域指针的移位。该方案中频域指针偏转的原因是不同频率的后选概率不同,导致频谱幅值的重排。用真实微弱值的微弱测量方法估计时延,在某些敏感区域可以达到与标准微弱测量方法相同的高分辨率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Precision estimation of time delay based on weak measurement with real weak value
In the standard weak measurement, the imaginary part of the weak value is usually constructed with a specific pre- or postselection state to cause a large shift of the frequency-domain pointer. In this paper we demonstrate that the purely real weak value can also shift the frequency-domain pointer when using a broad-spectrum light source. The reason for the deflection of the frequency-domain pointer in this scheme is that the postselection probability of different frequency is different, which causes the rearrangement of the amplitudes of the spectrum. The weak measurement with real weak value can be used for the estimation of time delay, and it is found that it can reach the same high resolution as the standard weak measurement in some sensitive regions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信