基于心率、氧气水平和体温的健康识别系统采用了模糊哺乳动物的方法

Arsal Wildan Naviaddin, Barlian Henryranu Prasetio, Rakhmadhany Primananda
{"title":"基于心率、氧气水平和体温的健康识别系统采用了模糊哺乳动物的方法","authors":"Arsal Wildan Naviaddin, Barlian Henryranu Prasetio, Rakhmadhany Primananda","doi":"10.25126/jtiik.20231056956","DOIUrl":null,"url":null,"abstract":"Kesehatan merupakan faktor penting dalam kehidupan manusia. Oleh karena itu, dalam paper ini kami menawarkan pendekatan efektif dan efisien dalam mendeteksi dini kesehatan. Deteksi dini dapat menghindari berbagai faktor risiko penyakit dan dapat terhindar dari komplikasi, serta menghemat biaya pengobatan. Sebagian besar alat deteksi kesehatan menggunakan metode invasif, sementara sistem kami menggunakan pendekatan contactless. Sensor pulse Oximater MAX30100 dan sensor suhu MLX90614 digunakan untuk mengukur tingkat saturasi oksigen, detak jantung dan suhu tubuh. Kemudian, kedua data sensor tersebut dikirim ke Google Firebase dengan memanfaatkan fitur layanan realtime database sehingga data dapat ditampilkan secara langsung di aplikasi android. Kedua sensor dihubungkan pada mikrokontroler NodeMCU ESP8266, lalu data hasil pengukuran sensor beserta perhitungan fuzzy dikirim ke database Firebase agar dapat ditampilkan pada smartphone. Hasil dari penelitian ini adalah akurasi pembacaan sensor suhu MLX90614 dan pulse oximater MAX30100 dibandingkan alat yang sudah ada didapatkan pengukuran suhu mendapatkan nilai MAPE sebesar 0.964 %, pengukuran saturasi mendapatkan nilai MAPE 0 %, dan pengukuran detak jantung didapatkan MAPE 1.581 %. Dari ketiga pengukuran didapatkan nilai MAPE dibawah 10% sehingga dapat dikategorikan pengukuran akurat dan kinerja metode fuzzy mamdani dalam mengklasifikasikan kondisi kesehatan sangat baik dan akurat. Abstract Health is an important factor in human life. Therefore, in this paper we offer an effective and efficient approach in early detection of health. Early detection can avoid various risk factors for disease and can avoid complications, as well as save on medical costs. Most medical detection systems use invasive methods, while our system uses a contactless approach. The MAX30100 Oximater pulse sensor and MLX90614 temperature sensor are used to measure oxygen saturation level, heart rate and body temperature. Then, the two-sensor data are sent to Google Firebase by utilizing the real-time database service feature so that the data can be displayed directly in the Android application. The two sensors are connected to the NodeMCU ESP8266 microcontroller, then the sensor measurement results data along with the fuzzy calculations are sent to the Firebase database so that they can be displayed on a smartphone. The results of this study are the accuracy of the readings of the MLX90614 temperature sensor and the MAX30100 pulse oximeter compared to existing devices, the temperature measurement gets a MAPE value of 0.964 %, the saturation measurement gets a MAPE value of 0 %, and the heart rate measurement gets a MAPE of 1.581 %. From the three measurements, the MAPE value was below 10% so that it could be categorized as an accurate measurement and the performance of the Mamdani fuzzy method in classifying health conditions was very good and accurate.","PeriodicalId":32501,"journal":{"name":"Jurnal Teknologi Informasi dan Ilmu Komputer","volume":"51 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sistem Identifikasi Kesehatan Berdasarkan Detak Jantung, Kadar Oksigen, dan Suhu Tubuh Menggunakan Metode Fuzzy Mamdani\",\"authors\":\"Arsal Wildan Naviaddin, Barlian Henryranu Prasetio, Rakhmadhany Primananda\",\"doi\":\"10.25126/jtiik.20231056956\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Kesehatan merupakan faktor penting dalam kehidupan manusia. Oleh karena itu, dalam paper ini kami menawarkan pendekatan efektif dan efisien dalam mendeteksi dini kesehatan. Deteksi dini dapat menghindari berbagai faktor risiko penyakit dan dapat terhindar dari komplikasi, serta menghemat biaya pengobatan. Sebagian besar alat deteksi kesehatan menggunakan metode invasif, sementara sistem kami menggunakan pendekatan contactless. Sensor pulse Oximater MAX30100 dan sensor suhu MLX90614 digunakan untuk mengukur tingkat saturasi oksigen, detak jantung dan suhu tubuh. Kemudian, kedua data sensor tersebut dikirim ke Google Firebase dengan memanfaatkan fitur layanan realtime database sehingga data dapat ditampilkan secara langsung di aplikasi android. Kedua sensor dihubungkan pada mikrokontroler NodeMCU ESP8266, lalu data hasil pengukuran sensor beserta perhitungan fuzzy dikirim ke database Firebase agar dapat ditampilkan pada smartphone. Hasil dari penelitian ini adalah akurasi pembacaan sensor suhu MLX90614 dan pulse oximater MAX30100 dibandingkan alat yang sudah ada didapatkan pengukuran suhu mendapatkan nilai MAPE sebesar 0.964 %, pengukuran saturasi mendapatkan nilai MAPE 0 %, dan pengukuran detak jantung didapatkan MAPE 1.581 %. Dari ketiga pengukuran didapatkan nilai MAPE dibawah 10% sehingga dapat dikategorikan pengukuran akurat dan kinerja metode fuzzy mamdani dalam mengklasifikasikan kondisi kesehatan sangat baik dan akurat. Abstract Health is an important factor in human life. Therefore, in this paper we offer an effective and efficient approach in early detection of health. Early detection can avoid various risk factors for disease and can avoid complications, as well as save on medical costs. Most medical detection systems use invasive methods, while our system uses a contactless approach. The MAX30100 Oximater pulse sensor and MLX90614 temperature sensor are used to measure oxygen saturation level, heart rate and body temperature. Then, the two-sensor data are sent to Google Firebase by utilizing the real-time database service feature so that the data can be displayed directly in the Android application. The two sensors are connected to the NodeMCU ESP8266 microcontroller, then the sensor measurement results data along with the fuzzy calculations are sent to the Firebase database so that they can be displayed on a smartphone. The results of this study are the accuracy of the readings of the MLX90614 temperature sensor and the MAX30100 pulse oximeter compared to existing devices, the temperature measurement gets a MAPE value of 0.964 %, the saturation measurement gets a MAPE value of 0 %, and the heart rate measurement gets a MAPE of 1.581 %. From the three measurements, the MAPE value was below 10% so that it could be categorized as an accurate measurement and the performance of the Mamdani fuzzy method in classifying health conditions was very good and accurate.\",\"PeriodicalId\":32501,\"journal\":{\"name\":\"Jurnal Teknologi Informasi dan Ilmu Komputer\",\"volume\":\"51 5\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teknologi Informasi dan Ilmu Komputer\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25126/jtiik.20231056956\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknologi Informasi dan Ilmu Komputer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25126/jtiik.20231056956","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

健康是人类生活的一个重要因素。因此,在这篇论文中,我们提供了一种有效有效的检测健康状况的方法。及早发现可以避免许多疾病风险因素,可以避免并发症,并节省医疗费用。大多数医疗检测工具使用侵入性方法,而我们的系统使用侵入性方法。MAX30100脉冲- Oximater和MLX90614温度传感器被用来测量氧饱和度、心率和体温。然后,这两个传感器数据都被发送到谷歌Firebase,使用数据库的实时服务功能,这样数据就可以直接显示在android应用程序中。这两种传感器都连接到NodeMCU NodeMCU ESP8266的微控制器上,然后传感器测量和模糊计算的数据被发送到Firebase数据库中,以便在智能手机上显示。这项研究的结果是,将MLX90614温度传感器的准确性与现有设备进行比较,将oxse MAX30100与现有设备进行比较。在这三种测量中,MAPE的值低于10%,因此可以对模糊乳房毛绒方法的准确测量和性能进行高度准确和准确的分类。抽象健康在人类生活中是一个重要的因素。因此,在这份报告中,我们提供了一种有效和有益的健康探测。早期探测可以预防疾病的各种风险因素,也可以节省医疗费用。大多数医疗检测器系统使用侵入性方法,而我们的系统uses是一种近亲。MAX30100脉冲传感器和MLX90614温度传感器用于可调性单水平、心率和体温。然后,2个数据传感器通过实用的数据库服务功能被发送到谷歌Firebase,这样数据就可以在Android应用程序中被直接屏蔽。这两种传感器连接到NodeMCU ESP8266微控制器,然后传感器根据模糊的计算数据发送到Firebase数据库,这样它们就可以发布在智能手机上。The results of this study评比》是阅读的《MLX90614温度传感器与MAX30100脉冲oximeter compared to existing测量的温度变得a MAPE价值》,带给您0.964 %,《saturation测量得到了a的MAPE价值0 %,和1581人之心率测量得到的a MAPE %。从三种测量结果来看,MAPE值低于10%,所以可以准确计算出持久性模糊的方法,并准确计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sistem Identifikasi Kesehatan Berdasarkan Detak Jantung, Kadar Oksigen, dan Suhu Tubuh Menggunakan Metode Fuzzy Mamdani
Kesehatan merupakan faktor penting dalam kehidupan manusia. Oleh karena itu, dalam paper ini kami menawarkan pendekatan efektif dan efisien dalam mendeteksi dini kesehatan. Deteksi dini dapat menghindari berbagai faktor risiko penyakit dan dapat terhindar dari komplikasi, serta menghemat biaya pengobatan. Sebagian besar alat deteksi kesehatan menggunakan metode invasif, sementara sistem kami menggunakan pendekatan contactless. Sensor pulse Oximater MAX30100 dan sensor suhu MLX90614 digunakan untuk mengukur tingkat saturasi oksigen, detak jantung dan suhu tubuh. Kemudian, kedua data sensor tersebut dikirim ke Google Firebase dengan memanfaatkan fitur layanan realtime database sehingga data dapat ditampilkan secara langsung di aplikasi android. Kedua sensor dihubungkan pada mikrokontroler NodeMCU ESP8266, lalu data hasil pengukuran sensor beserta perhitungan fuzzy dikirim ke database Firebase agar dapat ditampilkan pada smartphone. Hasil dari penelitian ini adalah akurasi pembacaan sensor suhu MLX90614 dan pulse oximater MAX30100 dibandingkan alat yang sudah ada didapatkan pengukuran suhu mendapatkan nilai MAPE sebesar 0.964 %, pengukuran saturasi mendapatkan nilai MAPE 0 %, dan pengukuran detak jantung didapatkan MAPE 1.581 %. Dari ketiga pengukuran didapatkan nilai MAPE dibawah 10% sehingga dapat dikategorikan pengukuran akurat dan kinerja metode fuzzy mamdani dalam mengklasifikasikan kondisi kesehatan sangat baik dan akurat. Abstract Health is an important factor in human life. Therefore, in this paper we offer an effective and efficient approach in early detection of health. Early detection can avoid various risk factors for disease and can avoid complications, as well as save on medical costs. Most medical detection systems use invasive methods, while our system uses a contactless approach. The MAX30100 Oximater pulse sensor and MLX90614 temperature sensor are used to measure oxygen saturation level, heart rate and body temperature. Then, the two-sensor data are sent to Google Firebase by utilizing the real-time database service feature so that the data can be displayed directly in the Android application. The two sensors are connected to the NodeMCU ESP8266 microcontroller, then the sensor measurement results data along with the fuzzy calculations are sent to the Firebase database so that they can be displayed on a smartphone. The results of this study are the accuracy of the readings of the MLX90614 temperature sensor and the MAX30100 pulse oximeter compared to existing devices, the temperature measurement gets a MAPE value of 0.964 %, the saturation measurement gets a MAPE value of 0 %, and the heart rate measurement gets a MAPE of 1.581 %. From the three measurements, the MAPE value was below 10% so that it could be categorized as an accurate measurement and the performance of the Mamdani fuzzy method in classifying health conditions was very good and accurate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信