Kyungmin Jo, Youngran Lim, Kyoung-Seok Lee, Euijin Hwang
{"title":"在韩国标准科学研究院开发库仑计系统,并对该系统产生的测量不确定度进行评估","authors":"Kyungmin Jo, Youngran Lim, Kyoung-Seok Lee, Euijin Hwang","doi":"10.1088/1681-7575/acff75","DOIUrl":null,"url":null,"abstract":"Abstract Coulometry is used to realize the definition of the mole and enables the direct determination of the purity of high-purity substances that are used as standards for other relative measurements with very small measurement uncertainty. However, despite several studies reporting the development of accurate and precise coulometry systems, there is a lack of detailed description of the system and systematic evaluation of the measurement uncertainty arising from the system. In this study, coulometry systems constructed at the Korea Research Institute of Standards and Science (KRISS) are described in detail and the uncertainties associated with these systems are systematically evaluated using a bottom-up approach. The relative expanded uncertainty resulting from the measurement system for the amount-of-substance content of acid in high-purity potassium hydrogen phthalate is approximately 0.0005%. The performance of the KRISS coulometry systems has been verified through several international comparisons and comparative measurements using certified reference materials.","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":"279 1","pages":"0"},"PeriodicalIF":2.1000,"publicationDate":"2023-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a coulometry system at the Korea Research Institute of Standards and Science and evaluation of the measurement uncertainty originating from the system\",\"authors\":\"Kyungmin Jo, Youngran Lim, Kyoung-Seok Lee, Euijin Hwang\",\"doi\":\"10.1088/1681-7575/acff75\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Coulometry is used to realize the definition of the mole and enables the direct determination of the purity of high-purity substances that are used as standards for other relative measurements with very small measurement uncertainty. However, despite several studies reporting the development of accurate and precise coulometry systems, there is a lack of detailed description of the system and systematic evaluation of the measurement uncertainty arising from the system. In this study, coulometry systems constructed at the Korea Research Institute of Standards and Science (KRISS) are described in detail and the uncertainties associated with these systems are systematically evaluated using a bottom-up approach. The relative expanded uncertainty resulting from the measurement system for the amount-of-substance content of acid in high-purity potassium hydrogen phthalate is approximately 0.0005%. The performance of the KRISS coulometry systems has been verified through several international comparisons and comparative measurements using certified reference materials.\",\"PeriodicalId\":18444,\"journal\":{\"name\":\"Metrologia\",\"volume\":\"279 1\",\"pages\":\"0\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-10-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1681-7575/acff75\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1681-7575/acff75","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Development of a coulometry system at the Korea Research Institute of Standards and Science and evaluation of the measurement uncertainty originating from the system
Abstract Coulometry is used to realize the definition of the mole and enables the direct determination of the purity of high-purity substances that are used as standards for other relative measurements with very small measurement uncertainty. However, despite several studies reporting the development of accurate and precise coulometry systems, there is a lack of detailed description of the system and systematic evaluation of the measurement uncertainty arising from the system. In this study, coulometry systems constructed at the Korea Research Institute of Standards and Science (KRISS) are described in detail and the uncertainties associated with these systems are systematically evaluated using a bottom-up approach. The relative expanded uncertainty resulting from the measurement system for the amount-of-substance content of acid in high-purity potassium hydrogen phthalate is approximately 0.0005%. The performance of the KRISS coulometry systems has been verified through several international comparisons and comparative measurements using certified reference materials.
期刊介绍:
Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them.
The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics.
In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.