Zhiqing Yao, Danyang Li, Zhiyong Li, Pengpeng Zhou, Lei Li
{"title":"基于数字孪生的继电保护镜像操作技术","authors":"Zhiqing Yao, Danyang Li, Zhiyong Li, Pengpeng Zhou, Lei Li","doi":"10.1186/s41601-023-00328-4","DOIUrl":null,"url":null,"abstract":"Abstract When conducting relay protection research, research costs can be significantly reduced if protection principle development, protection parameter verification and debugging can be carried out without relying on actual protection devices. The concept of ‘digital twin’ has made this possible, but the existing research has shortcomings in real-time data interaction ability, protection logic transparency, interface standardization, human–computer interaction etc., and consequently, mirror operation of relay protection in digital space has not been fully realized. Therefore, referring to the characteristics of digital twin, and combining with the practical application requirements in relay protection, this paper proposes the concept and characteristics of relay protection mirror operation based on digital twin. Key solutions are proposed to address the difficulties that may be encountered in the implementation of relay protection mirror operation in terms of protection principles, interfaces, real-time operation of the system, and human–computer interaction function simulation. Finally, an example of 110 kV double-bus and double-branch bus protection is used to verify the feasibility and progressiveness of the scheme proposed in this paper by comparing the action behavior and external characteristics of the twin protection and the actual protection device. The presented research can provide a reference for further in-depth research and application of relay protection using digital means.","PeriodicalId":51639,"journal":{"name":"Protection and Control of Modern Power Systems","volume":"129 1","pages":"0"},"PeriodicalIF":8.7000,"publicationDate":"2023-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Relay protection mirror operation technology based on digital twin\",\"authors\":\"Zhiqing Yao, Danyang Li, Zhiyong Li, Pengpeng Zhou, Lei Li\",\"doi\":\"10.1186/s41601-023-00328-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract When conducting relay protection research, research costs can be significantly reduced if protection principle development, protection parameter verification and debugging can be carried out without relying on actual protection devices. The concept of ‘digital twin’ has made this possible, but the existing research has shortcomings in real-time data interaction ability, protection logic transparency, interface standardization, human–computer interaction etc., and consequently, mirror operation of relay protection in digital space has not been fully realized. Therefore, referring to the characteristics of digital twin, and combining with the practical application requirements in relay protection, this paper proposes the concept and characteristics of relay protection mirror operation based on digital twin. Key solutions are proposed to address the difficulties that may be encountered in the implementation of relay protection mirror operation in terms of protection principles, interfaces, real-time operation of the system, and human–computer interaction function simulation. Finally, an example of 110 kV double-bus and double-branch bus protection is used to verify the feasibility and progressiveness of the scheme proposed in this paper by comparing the action behavior and external characteristics of the twin protection and the actual protection device. The presented research can provide a reference for further in-depth research and application of relay protection using digital means.\",\"PeriodicalId\":51639,\"journal\":{\"name\":\"Protection and Control of Modern Power Systems\",\"volume\":\"129 1\",\"pages\":\"0\"},\"PeriodicalIF\":8.7000,\"publicationDate\":\"2023-10-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Protection and Control of Modern Power Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s41601-023-00328-4\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Protection and Control of Modern Power Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41601-023-00328-4","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
Relay protection mirror operation technology based on digital twin
Abstract When conducting relay protection research, research costs can be significantly reduced if protection principle development, protection parameter verification and debugging can be carried out without relying on actual protection devices. The concept of ‘digital twin’ has made this possible, but the existing research has shortcomings in real-time data interaction ability, protection logic transparency, interface standardization, human–computer interaction etc., and consequently, mirror operation of relay protection in digital space has not been fully realized. Therefore, referring to the characteristics of digital twin, and combining with the practical application requirements in relay protection, this paper proposes the concept and characteristics of relay protection mirror operation based on digital twin. Key solutions are proposed to address the difficulties that may be encountered in the implementation of relay protection mirror operation in terms of protection principles, interfaces, real-time operation of the system, and human–computer interaction function simulation. Finally, an example of 110 kV double-bus and double-branch bus protection is used to verify the feasibility and progressiveness of the scheme proposed in this paper by comparing the action behavior and external characteristics of the twin protection and the actual protection device. The presented research can provide a reference for further in-depth research and application of relay protection using digital means.
期刊介绍:
Protection and Control of Modern Power Systems (PCMP) is the first international modern power system protection and control journal originated in China. The journal is dedicated to presenting top-level academic achievements in this field and aims to provide a platform for international researchers and engineers, with a special focus on authors from China, to maximize the papers' impact worldwide and contribute to the development of the power industry. PCMP is sponsored by Xuchang Ketop Electrical Research Institute and is edited and published by Power System Protection and Control Press.
PCMP focuses on advanced views, techniques, methodologies, and experience in the field of protection and control of modern power systems to showcase the latest technological achievements. However, it is important to note that the journal will cease to be published by SpringerOpen as of 31 December 2023. Nonetheless, it will continue in cooperation with a new publisher.