Seungjun Yoo, Hubeom Shin, Seokwon Oh, Junho Lee, Hunhee Kim, Ho Kyung Kim
{"title":"高能透射射线照相用薄荧光粉探测器的吸收信号和噪声分析","authors":"Seungjun Yoo, Hubeom Shin, Seokwon Oh, Junho Lee, Hunhee Kim, Ho Kyung Kim","doi":"10.1088/1748-0221/18/10/c10017","DOIUrl":null,"url":null,"abstract":"Abstract We investigated the detective quantum efficiency (DQE) of thin gadolinium oxysulfide phosphor-based flat-panel detectors (FPDs) using cascaded-systems analysis and Monte Carlo (MC) simulations for applications in megavoltage (MV) x-ray industrial imaging. We decomposed the DQE formula into (dose-independent) upper-limit DQE and (dose-dependent) DQE-reduction factors. We obtained the absorbed energy distributions (AEDs) for various x-ray detector designs and photon energies using MC simulations and applied the AED analysis to the DQE formula. The investigations examined include the x-ray-detector-only DQE and the effect of the coupling efficiency between the x-ray detector and readout panel, including electronic noise, on the upper-limit DQE. This study confirms that the design of the metal build-up layer on the phosphor is effective for MV imaging and emphasizes the importance of designing the readout panel to maintain the upper-limit DQE. We expect the proposed DQE analysis to be suitable for designing and evaluating FPDs for high-energy nondestructive x-ray testing.","PeriodicalId":16184,"journal":{"name":"Journal of Instrumentation","volume":"121 1","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of absorption signal and noise in thin phosphor detectors for high-energy transmission radiography\",\"authors\":\"Seungjun Yoo, Hubeom Shin, Seokwon Oh, Junho Lee, Hunhee Kim, Ho Kyung Kim\",\"doi\":\"10.1088/1748-0221/18/10/c10017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract We investigated the detective quantum efficiency (DQE) of thin gadolinium oxysulfide phosphor-based flat-panel detectors (FPDs) using cascaded-systems analysis and Monte Carlo (MC) simulations for applications in megavoltage (MV) x-ray industrial imaging. We decomposed the DQE formula into (dose-independent) upper-limit DQE and (dose-dependent) DQE-reduction factors. We obtained the absorbed energy distributions (AEDs) for various x-ray detector designs and photon energies using MC simulations and applied the AED analysis to the DQE formula. The investigations examined include the x-ray-detector-only DQE and the effect of the coupling efficiency between the x-ray detector and readout panel, including electronic noise, on the upper-limit DQE. This study confirms that the design of the metal build-up layer on the phosphor is effective for MV imaging and emphasizes the importance of designing the readout panel to maintain the upper-limit DQE. We expect the proposed DQE analysis to be suitable for designing and evaluating FPDs for high-energy nondestructive x-ray testing.\",\"PeriodicalId\":16184,\"journal\":{\"name\":\"Journal of Instrumentation\",\"volume\":\"121 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/1748-0221/18/10/c10017\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/1748-0221/18/10/c10017","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Analysis of absorption signal and noise in thin phosphor detectors for high-energy transmission radiography
Abstract We investigated the detective quantum efficiency (DQE) of thin gadolinium oxysulfide phosphor-based flat-panel detectors (FPDs) using cascaded-systems analysis and Monte Carlo (MC) simulations for applications in megavoltage (MV) x-ray industrial imaging. We decomposed the DQE formula into (dose-independent) upper-limit DQE and (dose-dependent) DQE-reduction factors. We obtained the absorbed energy distributions (AEDs) for various x-ray detector designs and photon energies using MC simulations and applied the AED analysis to the DQE formula. The investigations examined include the x-ray-detector-only DQE and the effect of the coupling efficiency between the x-ray detector and readout panel, including electronic noise, on the upper-limit DQE. This study confirms that the design of the metal build-up layer on the phosphor is effective for MV imaging and emphasizes the importance of designing the readout panel to maintain the upper-limit DQE. We expect the proposed DQE analysis to be suitable for designing and evaluating FPDs for high-energy nondestructive x-ray testing.
期刊介绍:
Journal of Instrumentation (JINST) covers major areas related to concepts and instrumentation in detector physics, accelerator science and associated experimental methods and techniques, theory, modelling and simulations. The main subject areas include.
-Accelerators: concepts, modelling, simulations and sources-
Instrumentation and hardware for accelerators: particles, synchrotron radiation, neutrons-
Detector physics: concepts, processes, methods, modelling and simulations-
Detectors, apparatus and methods for particle, astroparticle, nuclear, atomic, and molecular physics-
Instrumentation and methods for plasma research-
Methods and apparatus for astronomy and astrophysics-
Detectors, methods and apparatus for biomedical applications, life sciences and material research-
Instrumentation and techniques for medical imaging, diagnostics and therapy-
Instrumentation and techniques for dosimetry, monitoring and radiation damage-
Detectors, instrumentation and methods for non-destructive tests (NDT)-
Detector readout concepts, electronics and data acquisition methods-
Algorithms, software and data reduction methods-
Materials and associated technologies, etc.-
Engineering and technical issues.
JINST also includes a section dedicated to technical reports and instrumentation theses.