不同阶段升温速率下EN AB-42000铝合金流变铸造半固态的差示扫描量热法

IF 2.3 Q2 ENGINEERING, CIVIL
Kawan M. Abdulrahman, Viktor Gonda, Mihály Réger
{"title":"不同阶段升温速率下EN AB-42000铝合金流变铸造半固态的差示扫描量热法","authors":"Kawan M. Abdulrahman, Viktor Gonda, Mihály Réger","doi":"10.1007/s41062-023-01256-w","DOIUrl":null,"url":null,"abstract":"Abstract Differential scanning calorimetry (DSC) is used to identify the thermal histories of samples to analyse and diagnose production and quality concerns connected to industrial rheocasting semi-solid alloy, that had undergone different tempers of aluminium alloy EN AB-42000 alloy. In this study, the solidus temperatures of several alloy samples are investigated using thermodynamic calculations and DSC observations in this work. The balance of important characteristics, including pseudo-eutectic, thermal sensitivity, heat flow, and enthalpies behaviour, of Al alloys has been investigated using experimental data from DSC and solid fractions. In addition, the choice of heating rates is critical as high rates can blur the two peaks in the mushy zone, while low rates lead to slower measurements. Using smaller sample weights and slower rates is preferable to obtain more accurate results. Analysing the shape of the fs curve, exact composition, and a reference composition without contaminants is essential for understanding complex behaviours, including pseudo-eutectic phenomena. The thermal sensitivity of compositions also plays a crucial role in the analysis. Despite heat flow decreasing with decreased sample weight, the measurement limit can still be exceeded at high heating or cooling rates (20 °C/min) during the eutectic reaction. The eutectic reaction exhibits higher peaks with enthalpies ranging from 360 to 430 mJ/g. However, drawing conclusions regarding trends in heating versus cooling or comparing low-mass and higher-mass samples can be challenging. The non-equilibrium transformation of the eutectic occurs within a more confined temperature range. Increasing rates lead to overlapping reactions, resulting in complex thermal behaviour.","PeriodicalId":13525,"journal":{"name":"Innovative Infrastructure Solutions","volume":"32 1","pages":"0"},"PeriodicalIF":2.3000,"publicationDate":"2023-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Differential scanning calorimetry of aluminium EN AB-42000 alloy rheocasting semi-solid in different stage heating rates\",\"authors\":\"Kawan M. Abdulrahman, Viktor Gonda, Mihály Réger\",\"doi\":\"10.1007/s41062-023-01256-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Differential scanning calorimetry (DSC) is used to identify the thermal histories of samples to analyse and diagnose production and quality concerns connected to industrial rheocasting semi-solid alloy, that had undergone different tempers of aluminium alloy EN AB-42000 alloy. In this study, the solidus temperatures of several alloy samples are investigated using thermodynamic calculations and DSC observations in this work. The balance of important characteristics, including pseudo-eutectic, thermal sensitivity, heat flow, and enthalpies behaviour, of Al alloys has been investigated using experimental data from DSC and solid fractions. In addition, the choice of heating rates is critical as high rates can blur the two peaks in the mushy zone, while low rates lead to slower measurements. Using smaller sample weights and slower rates is preferable to obtain more accurate results. Analysing the shape of the fs curve, exact composition, and a reference composition without contaminants is essential for understanding complex behaviours, including pseudo-eutectic phenomena. The thermal sensitivity of compositions also plays a crucial role in the analysis. Despite heat flow decreasing with decreased sample weight, the measurement limit can still be exceeded at high heating or cooling rates (20 °C/min) during the eutectic reaction. The eutectic reaction exhibits higher peaks with enthalpies ranging from 360 to 430 mJ/g. However, drawing conclusions regarding trends in heating versus cooling or comparing low-mass and higher-mass samples can be challenging. The non-equilibrium transformation of the eutectic occurs within a more confined temperature range. Increasing rates lead to overlapping reactions, resulting in complex thermal behaviour.\",\"PeriodicalId\":13525,\"journal\":{\"name\":\"Innovative Infrastructure Solutions\",\"volume\":\"32 1\",\"pages\":\"0\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Innovative Infrastructure Solutions\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s41062-023-01256-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Innovative Infrastructure Solutions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s41062-023-01256-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

摘要采用差示扫描量热法(DSC)对经过不同回火状态的铝合金EN AB-42000的工业流变铸造半固态合金样品进行热史分析和质量诊断。本研究采用热力学计算和DSC观测对几种合金样品的固相温度进行了研究。利用DSC和固体组分的实验数据,研究了铝合金的重要特性,包括伪共晶、热敏性、热流和焓行为的平衡。此外,加热速率的选择是至关重要的,因为高速率可以模糊糊状区域的两个峰,而低速率导致较慢的测量。使用较小的样本权重和较慢的速率可以获得更准确的结果。分析fs曲线的形状、精确成分和不含污染物的参考成分对于理解包括伪共晶现象在内的复杂行为至关重要。组分的热敏度在分析中也起着至关重要的作用。尽管热流随着样品重量的减少而减少,但在共晶反应过程中,在高加热或冷却速率(20°C/min)下,仍然可以超过测量极限。共晶反应峰较高,焓值在360 ~ 430 mJ/g之间。然而,得出关于加热与冷却趋势的结论或比较低质量和高质量样品可能具有挑战性。共晶的非平衡转变发生在一个更有限的温度范围内。增加的速率导致重叠反应,导致复杂的热行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Differential scanning calorimetry of aluminium EN AB-42000 alloy rheocasting semi-solid in different stage heating rates
Abstract Differential scanning calorimetry (DSC) is used to identify the thermal histories of samples to analyse and diagnose production and quality concerns connected to industrial rheocasting semi-solid alloy, that had undergone different tempers of aluminium alloy EN AB-42000 alloy. In this study, the solidus temperatures of several alloy samples are investigated using thermodynamic calculations and DSC observations in this work. The balance of important characteristics, including pseudo-eutectic, thermal sensitivity, heat flow, and enthalpies behaviour, of Al alloys has been investigated using experimental data from DSC and solid fractions. In addition, the choice of heating rates is critical as high rates can blur the two peaks in the mushy zone, while low rates lead to slower measurements. Using smaller sample weights and slower rates is preferable to obtain more accurate results. Analysing the shape of the fs curve, exact composition, and a reference composition without contaminants is essential for understanding complex behaviours, including pseudo-eutectic phenomena. The thermal sensitivity of compositions also plays a crucial role in the analysis. Despite heat flow decreasing with decreased sample weight, the measurement limit can still be exceeded at high heating or cooling rates (20 °C/min) during the eutectic reaction. The eutectic reaction exhibits higher peaks with enthalpies ranging from 360 to 430 mJ/g. However, drawing conclusions regarding trends in heating versus cooling or comparing low-mass and higher-mass samples can be challenging. The non-equilibrium transformation of the eutectic occurs within a more confined temperature range. Increasing rates lead to overlapping reactions, resulting in complex thermal behaviour.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.80
自引率
16.70%
发文量
250
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信