Indra Hermawan, Muhammad Idris, Anggih Prasetyo Wibisono, Habib Satria
{"title":"2 × 7mw煤基蒸汽电厂火用分析","authors":"Indra Hermawan, Muhammad Idris, Anggih Prasetyo Wibisono, Habib Satria","doi":"10.31258/ijeepse.6.3.200-204","DOIUrl":null,"url":null,"abstract":"In this study, an analysis was conducted on a steam power plant system with a capacity of 2 x 7 MW based on coal. The coal fuel used by the majority of refined sizes is not in accordance with the recommendations of the American Society of Mechanical Engineers (ASME). The main objective of the study was to analyze the system components separately and to measure the exergy value of the components, covering the electrical energy so that it is known which equipment experiences the greatest energy loss as well as knowing the efficiency value of the equipment used. Efficiency and exergy are calculated using plant operation data. The results of the study found that the largest exergy destruction occurred in boilers, meaning that there was the largest energy loss in this section with a value of 37.34 MW (16.71%), while the destruction of the smallest exergy occurred in condensers of 0.58 MW (99.24%).
","PeriodicalId":303470,"journal":{"name":"International Journal of Electrical, Energy and Power System Engineering","volume":"176 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exergy Analysis of Coal-Based 2 X 7 MW Steam Power Plant\",\"authors\":\"Indra Hermawan, Muhammad Idris, Anggih Prasetyo Wibisono, Habib Satria\",\"doi\":\"10.31258/ijeepse.6.3.200-204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, an analysis was conducted on a steam power plant system with a capacity of 2 x 7 MW based on coal. The coal fuel used by the majority of refined sizes is not in accordance with the recommendations of the American Society of Mechanical Engineers (ASME). The main objective of the study was to analyze the system components separately and to measure the exergy value of the components, covering the electrical energy so that it is known which equipment experiences the greatest energy loss as well as knowing the efficiency value of the equipment used. Efficiency and exergy are calculated using plant operation data. The results of the study found that the largest exergy destruction occurred in boilers, meaning that there was the largest energy loss in this section with a value of 37.34 MW (16.71%), while the destruction of the smallest exergy occurred in condensers of 0.58 MW (99.24%).
\",\"PeriodicalId\":303470,\"journal\":{\"name\":\"International Journal of Electrical, Energy and Power System Engineering\",\"volume\":\"176 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical, Energy and Power System Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31258/ijeepse.6.3.200-204\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical, Energy and Power System Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31258/ijeepse.6.3.200-204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在这项研究中,分析了一个容量为2 x 7 MW的燃煤蒸汽发电厂系统。大多数精炼尺寸所使用的煤燃料不符合美国机械工程师协会(ASME)的建议。研究的主要目的是单独分析系统组件,测量组件的火用值,覆盖电能,从而知道哪些设备经历最大的能量损失,以及知道所使用设备的效率值。利用电厂运行数据计算效率和火用。研究结果发现,锅炉的火用破坏最大,即该区段的能量损失最大,损失值为37.34 MW(16.71%),而冷凝器的火用破坏最小,损失值为0.58 MW(99.24%)。
Exergy Analysis of Coal-Based 2 X 7 MW Steam Power Plant
In this study, an analysis was conducted on a steam power plant system with a capacity of 2 x 7 MW based on coal. The coal fuel used by the majority of refined sizes is not in accordance with the recommendations of the American Society of Mechanical Engineers (ASME). The main objective of the study was to analyze the system components separately and to measure the exergy value of the components, covering the electrical energy so that it is known which equipment experiences the greatest energy loss as well as knowing the efficiency value of the equipment used. Efficiency and exergy are calculated using plant operation data. The results of the study found that the largest exergy destruction occurred in boilers, meaning that there was the largest energy loss in this section with a value of 37.34 MW (16.71%), while the destruction of the smallest exergy occurred in condensers of 0.58 MW (99.24%).