UHPFRC护套钢纤维含量对损伤柱加固的影响

IF 1.5 0 ENGINEERING, MULTIDISCIPLINARY
Hasan A. Alasmari
{"title":"UHPFRC护套钢纤维含量对损伤柱加固的影响","authors":"Hasan A. Alasmari","doi":"10.48084/etasr.6292","DOIUrl":null,"url":null,"abstract":"Steel fiber is a commonly used material to repair damaged concrete, caused by environmental or design issues. This study used various Micro-copper-coated Steel Fiber (MSF) content (0.0, 0.5, 2.0, and 2.5%) with varying aspect ratios (28, 37, and 45) as part of Ultra-High-Performance Fiber-Reinforced Concrete (UHPFRC) mixtures to repair damaged concrete columns using a 30 mm layer jacketing. Twelve columns were prepared and tested at first by loading them with roughly 90% of their ultimate axial load capacity. Damage was caused and the columns were subsequently strengthened and rebuilt using UHPFRC mixtures in 30-mm layer jacketing for a second test, to determine the effect of UHPFRC and MSF content on damaged and reinforced columns. The test results showed that the concrete properties improved as the MSF content increased to 2.0% of the volume fraction, beyond which there was a slight reduction. Additionally, the UHPFRC-strengthened columns with and without MSFs experienced higher load capacities than the corresponding unstrengthened. On the contrary, using 2.5% MSF in the UHPFRC decreased the loading capacity by 14% compared to the UHPFRC with 2.0% MSF. The strengthened column with 2.0% MSF content showed the highest load efficiency (165.7% compared to unstrengthened), along with substantial displacement and ductility.","PeriodicalId":11826,"journal":{"name":"Engineering, Technology & Applied Science Research","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Influence of UHPFRC Jacket Steel Fiber Content on Strengthening Damaged Columns\",\"authors\":\"Hasan A. Alasmari\",\"doi\":\"10.48084/etasr.6292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Steel fiber is a commonly used material to repair damaged concrete, caused by environmental or design issues. This study used various Micro-copper-coated Steel Fiber (MSF) content (0.0, 0.5, 2.0, and 2.5%) with varying aspect ratios (28, 37, and 45) as part of Ultra-High-Performance Fiber-Reinforced Concrete (UHPFRC) mixtures to repair damaged concrete columns using a 30 mm layer jacketing. Twelve columns were prepared and tested at first by loading them with roughly 90% of their ultimate axial load capacity. Damage was caused and the columns were subsequently strengthened and rebuilt using UHPFRC mixtures in 30-mm layer jacketing for a second test, to determine the effect of UHPFRC and MSF content on damaged and reinforced columns. The test results showed that the concrete properties improved as the MSF content increased to 2.0% of the volume fraction, beyond which there was a slight reduction. Additionally, the UHPFRC-strengthened columns with and without MSFs experienced higher load capacities than the corresponding unstrengthened. On the contrary, using 2.5% MSF in the UHPFRC decreased the loading capacity by 14% compared to the UHPFRC with 2.0% MSF. The strengthened column with 2.0% MSF content showed the highest load efficiency (165.7% compared to unstrengthened), along with substantial displacement and ductility.\",\"PeriodicalId\":11826,\"journal\":{\"name\":\"Engineering, Technology & Applied Science Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering, Technology & Applied Science Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.48084/etasr.6292\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering, Technology & Applied Science Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48084/etasr.6292","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

钢纤维是修复因环境或设计问题而损坏的混凝土的常用材料。本研究使用不同的微铜涂层钢纤维(MSF)含量(0.0、0.5、2.0和2.5%)和不同的宽高比(28、37和45)作为超高性能纤维增强混凝土(UHPFRC)混合物的一部分,使用30毫米层护套修复受损的混凝土柱。12个柱被准备和测试,首先通过加载他们大约90%的极限轴向载荷能力。在第二次试验中,在30mm层护套中使用UHPFRC混合物对柱进行加固和重建,以确定UHPFRC和MSF含量对受损和加固柱的影响。试验结果表明,当MSF含量增加到体积分数的2.0%时,混凝土性能有所改善,超过该分数后,混凝土性能略有下降。此外,有和没有msf的uhpfrc加固柱比相应的未加固柱具有更高的承载能力。相反,与使用2.0% MSF的UHPFRC相比,在UHPFRC中使用2.5% MSF的承载能力降低了14%。当MSF含量为2.0%时,加固柱的荷载效率最高(比未加固柱高165.7%),且具有较大的位移和延性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Influence of UHPFRC Jacket Steel Fiber Content on Strengthening Damaged Columns
Steel fiber is a commonly used material to repair damaged concrete, caused by environmental or design issues. This study used various Micro-copper-coated Steel Fiber (MSF) content (0.0, 0.5, 2.0, and 2.5%) with varying aspect ratios (28, 37, and 45) as part of Ultra-High-Performance Fiber-Reinforced Concrete (UHPFRC) mixtures to repair damaged concrete columns using a 30 mm layer jacketing. Twelve columns were prepared and tested at first by loading them with roughly 90% of their ultimate axial load capacity. Damage was caused and the columns were subsequently strengthened and rebuilt using UHPFRC mixtures in 30-mm layer jacketing for a second test, to determine the effect of UHPFRC and MSF content on damaged and reinforced columns. The test results showed that the concrete properties improved as the MSF content increased to 2.0% of the volume fraction, beyond which there was a slight reduction. Additionally, the UHPFRC-strengthened columns with and without MSFs experienced higher load capacities than the corresponding unstrengthened. On the contrary, using 2.5% MSF in the UHPFRC decreased the loading capacity by 14% compared to the UHPFRC with 2.0% MSF. The strengthened column with 2.0% MSF content showed the highest load efficiency (165.7% compared to unstrengthened), along with substantial displacement and ductility.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Engineering, Technology & Applied Science Research
Engineering, Technology & Applied Science Research ENGINEERING, MULTIDISCIPLINARY-
CiteScore
3.00
自引率
46.70%
发文量
222
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信