在化合物特异性羟脯氨酸测年过程中实现低背景:高效液相色谱柱效应

IF 2 3区 地球科学 Q2 GEOCHEMISTRY & GEOPHYSICS
Radiocarbon Pub Date : 2023-10-31 DOI:10.1017/rdc.2023.86
Bethan Linscott, Luke Spindler, Jamie Cameron, David Chivall, Rachel Wood
{"title":"在化合物特异性羟脯氨酸测年过程中实现低背景:高效液相色谱柱效应","authors":"Bethan Linscott, Luke Spindler, Jamie Cameron, David Chivall, Rachel Wood","doi":"10.1017/rdc.2023.86","DOIUrl":null,"url":null,"abstract":"ABSTRACT Accelerator mass spectrometry (AMS) radiocarbon ( 14 C) dating is central to the development of robust chronologies in archaeological and paleoenvironmental contexts spanning the last 50,000 years. For dates to be accurate, samples must be free of exogenous carbon contamination. At the Oxford Radiocarbon Accelerator Unit (ORAU), considerable advancements in the dating of bone collagen have been made through the development of a high performance liquid chromatography (HPLC) method for the dating of the amino acid hydroxyproline, which can mitigate the effects of carbon contamination. However, recent changes in ligand manufacturing methods for the mixed-mode column used in the ORAU protocol (Primesep A, SIELC Technologies; IL, USA) have resulted in unacceptably high analytical backgrounds. Prior to the manufacturing change, backgrounds of > 50k BP were achievable. Since the manufacturing change, a mean background of 32.5k BP has been measured. Due to column bleed, the Primesep A is therefore no longer suitable for 14 C measurement of hydroxyproline from older material. Here, we present background data and the chromatography conditions used to isolate hydroxyproline using an alternative column, a preparative-scale Newcrom AH, which shows promising potential as an alternative for the routine isolation and AMS dating of hydroxyproline—especially approaching the age and mass limits of the method.","PeriodicalId":21020,"journal":{"name":"Radiocarbon","volume":"145 ","pages":"0"},"PeriodicalIF":2.0000,"publicationDate":"2023-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ACHIEVING LOW BACKGROUNDS DURING COMPOUND-SPECIFIC HYDROXYPROLINE DATING: HPLC COLUMN EFFECTS\",\"authors\":\"Bethan Linscott, Luke Spindler, Jamie Cameron, David Chivall, Rachel Wood\",\"doi\":\"10.1017/rdc.2023.86\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Accelerator mass spectrometry (AMS) radiocarbon ( 14 C) dating is central to the development of robust chronologies in archaeological and paleoenvironmental contexts spanning the last 50,000 years. For dates to be accurate, samples must be free of exogenous carbon contamination. At the Oxford Radiocarbon Accelerator Unit (ORAU), considerable advancements in the dating of bone collagen have been made through the development of a high performance liquid chromatography (HPLC) method for the dating of the amino acid hydroxyproline, which can mitigate the effects of carbon contamination. However, recent changes in ligand manufacturing methods for the mixed-mode column used in the ORAU protocol (Primesep A, SIELC Technologies; IL, USA) have resulted in unacceptably high analytical backgrounds. Prior to the manufacturing change, backgrounds of > 50k BP were achievable. Since the manufacturing change, a mean background of 32.5k BP has been measured. Due to column bleed, the Primesep A is therefore no longer suitable for 14 C measurement of hydroxyproline from older material. Here, we present background data and the chromatography conditions used to isolate hydroxyproline using an alternative column, a preparative-scale Newcrom AH, which shows promising potential as an alternative for the routine isolation and AMS dating of hydroxyproline—especially approaching the age and mass limits of the method.\",\"PeriodicalId\":21020,\"journal\":{\"name\":\"Radiocarbon\",\"volume\":\"145 \",\"pages\":\"0\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiocarbon\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/rdc.2023.86\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"GEOCHEMISTRY & GEOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiocarbon","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/rdc.2023.86","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOCHEMISTRY & GEOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

加速器质谱法(AMS)放射性碳(14c)定年对于在过去5万年的考古和古环境背景下建立可靠的年表至关重要。为了使日期准确,样品必须没有外源性碳污染。在牛津放射性碳加速器单元(ORAU),通过开发一种高效液相色谱(HPLC)方法来测定氨基酸羟基脯氨酸的年代,在骨胶原的年代测定方面取得了相当大的进展,这种方法可以减轻碳污染的影响。然而,最近ORAU协议中使用的混合模式色谱的配体制造方法发生了变化(Primesep A, SIELC Technologies;IL,美国)导致了不可接受的高分析背景。在制造业变革之前,>50k BP是可以实现的。自制造业变化以来,测量了32.5k BP的平均背景。由于柱出血,Primesep A因此不再适用于旧材料中羟脯氨酸的14c测量。在这里,我们提供了背景数据和色谱条件,用于分离羟基脯氨酸,使用另一种色谱柱,制备规模的Newcrom AH,它显示出有希望的潜力,作为常规分离和羟基脯氨酸的AMS定年-特别是接近年龄和质量限制的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ACHIEVING LOW BACKGROUNDS DURING COMPOUND-SPECIFIC HYDROXYPROLINE DATING: HPLC COLUMN EFFECTS
ABSTRACT Accelerator mass spectrometry (AMS) radiocarbon ( 14 C) dating is central to the development of robust chronologies in archaeological and paleoenvironmental contexts spanning the last 50,000 years. For dates to be accurate, samples must be free of exogenous carbon contamination. At the Oxford Radiocarbon Accelerator Unit (ORAU), considerable advancements in the dating of bone collagen have been made through the development of a high performance liquid chromatography (HPLC) method for the dating of the amino acid hydroxyproline, which can mitigate the effects of carbon contamination. However, recent changes in ligand manufacturing methods for the mixed-mode column used in the ORAU protocol (Primesep A, SIELC Technologies; IL, USA) have resulted in unacceptably high analytical backgrounds. Prior to the manufacturing change, backgrounds of > 50k BP were achievable. Since the manufacturing change, a mean background of 32.5k BP has been measured. Due to column bleed, the Primesep A is therefore no longer suitable for 14 C measurement of hydroxyproline from older material. Here, we present background data and the chromatography conditions used to isolate hydroxyproline using an alternative column, a preparative-scale Newcrom AH, which shows promising potential as an alternative for the routine isolation and AMS dating of hydroxyproline—especially approaching the age and mass limits of the method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiocarbon
Radiocarbon 地学-地球化学与地球物理
CiteScore
16.20
自引率
6.00%
发文量
85
审稿时长
6-12 weeks
期刊介绍: Radiocarbon serves as the leading international journal for technical and interpretive articles, date lists, and advancements in 14C and other radioisotopes relevant to archaeological, geophysical, oceanographic, and related dating methods. Established in 1959, it has published numerous seminal works and hosts the triennial International Radiocarbon Conference proceedings. The journal also features occasional special issues. Submissions encompass regular articles such as research reports, technical descriptions, and date lists, along with comments, letters to the editor, book reviews, and laboratory lists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信