分析线粒体分析方法和光学分析方法的血小板分析结果(根据红血病指数)

Maulina Rosida, Budiono Raharjo, Halik Wijaya
{"title":"分析线粒体分析方法和光学分析方法的血小板分析结果(根据红血病指数)","authors":"Maulina Rosida, Budiono Raharjo, Halik Wijaya","doi":"10.51804/jsh.v7i1.6848.41-46","DOIUrl":null,"url":null,"abstract":"Platelets have an important role in hemostasis, namely the formation and stabilization of platelet plugs. There are several methods in the counting of platelets. They can be carried out in a direct and an indirect manner. The direct method can be carried out in an automatic and automatic way. The automatic method uses an hematology analyzer which functions to measure and examine blood cells in blood samples. Counting the number of platelets is done automatically by two methods, namely optical and impedance which have different principles. The optical method is based on cell size and morphology, while impedance is based on cell size only. Hypochrome is a condition where the Hb concentration is less than normal so that the central achromia widens (> 1/3 of the cell) and there is a decrease in the color of the erythrocytes, namely an increase in the diameter of the central pallor above normal so that it looks paler. Microcyte is a condition where the cell size is smaller than normal. The purpose of this study was to determine the difference in the number of platelets in the hematology analyzer using the impedance method and the optical method in the case of microcytic hypochromic anemia (based on erythrocyte index) with a descriptive analytical research design. The test used is the paired t-test with a total sample of 30 samples. The results of platelets using the impedance method have an average of 339.37 * 103 / uL with a standard deviation of 120.294. The results of platelets using the optical method have an average of 314.70 * 103 / uL with a standard deviation of 113.569. A significant value of 0.000 significant value of (sig. < 0.05) can be concluded that there is a difference between the results of platelets on the hematology analyzer using the impedance method and the optical method in cases of microcytic hypochromic anemia (based on erythrocyte index). Keywords : Trombosit, Hipokrom Mikrositer, Hematology analyzer, Impedance, Optik.","PeriodicalId":326360,"journal":{"name":"Jurnal SainHealth","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisa Perbandingan Hasil Trombosit Pada Alat Hematologi Analyzer Metode Impedance dan Metode Optik Pada Kasus Anemia Hipokrom Mikrositer (Berdasarkan Indeks Eritrosit)\",\"authors\":\"Maulina Rosida, Budiono Raharjo, Halik Wijaya\",\"doi\":\"10.51804/jsh.v7i1.6848.41-46\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Platelets have an important role in hemostasis, namely the formation and stabilization of platelet plugs. There are several methods in the counting of platelets. They can be carried out in a direct and an indirect manner. The direct method can be carried out in an automatic and automatic way. The automatic method uses an hematology analyzer which functions to measure and examine blood cells in blood samples. Counting the number of platelets is done automatically by two methods, namely optical and impedance which have different principles. The optical method is based on cell size and morphology, while impedance is based on cell size only. Hypochrome is a condition where the Hb concentration is less than normal so that the central achromia widens (> 1/3 of the cell) and there is a decrease in the color of the erythrocytes, namely an increase in the diameter of the central pallor above normal so that it looks paler. Microcyte is a condition where the cell size is smaller than normal. The purpose of this study was to determine the difference in the number of platelets in the hematology analyzer using the impedance method and the optical method in the case of microcytic hypochromic anemia (based on erythrocyte index) with a descriptive analytical research design. The test used is the paired t-test with a total sample of 30 samples. The results of platelets using the impedance method have an average of 339.37 * 103 / uL with a standard deviation of 120.294. The results of platelets using the optical method have an average of 314.70 * 103 / uL with a standard deviation of 113.569. A significant value of 0.000 significant value of (sig. < 0.05) can be concluded that there is a difference between the results of platelets on the hematology analyzer using the impedance method and the optical method in cases of microcytic hypochromic anemia (based on erythrocyte index). Keywords : Trombosit, Hipokrom Mikrositer, Hematology analyzer, Impedance, Optik.\",\"PeriodicalId\":326360,\"journal\":{\"name\":\"Jurnal SainHealth\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal SainHealth\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51804/jsh.v7i1.6848.41-46\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal SainHealth","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51804/jsh.v7i1.6848.41-46","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

血小板在止血中具有重要作用,即血小板栓的形成和稳定。血小板计数有几种方法。它们可以以直接和间接的方式进行。直接法可以自动、自动地进行。自动方法使用血液学分析仪,其功能是测量和检查血液样本中的血细胞。血小板数量的自动计数有两种方法,即光学方法和阻抗方法,它们的原理不同。光学方法是基于细胞的大小和形态,而阻抗仅基于细胞的大小。低色素是指Hb浓度低于正常水平,导致中央色差变宽(>三分之一的细胞),红细胞的颜色减少,即中央苍白的直径比正常情况下增加,因此看起来更苍白。小细胞是一种细胞比正常细胞小的情况。本研究的目的是采用描述性分析研究设计,采用阻抗法和光学法测定小细胞性低色性贫血(基于红细胞指数)血液分析仪中血小板数量的差异。使用的检验是配对t检验,总样本为30个样本。阻抗法测定血小板的平均结果为339.37 * 103 / uL,标准差为120.294。光学法测定血小板的平均结果为314.70 * 103 / uL,标准差为113.569。显著值为0.000,显著值为(sig. <0.05),说明在小细胞性低色度贫血病例中,血液学分析仪上的血小板检测结果(基于红细胞指数)与阻抗法存在差异。关键词:Trombosit, Hipokrom micrositer,血液分析仪,阻抗,Optik
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analisa Perbandingan Hasil Trombosit Pada Alat Hematologi Analyzer Metode Impedance dan Metode Optik Pada Kasus Anemia Hipokrom Mikrositer (Berdasarkan Indeks Eritrosit)
Platelets have an important role in hemostasis, namely the formation and stabilization of platelet plugs. There are several methods in the counting of platelets. They can be carried out in a direct and an indirect manner. The direct method can be carried out in an automatic and automatic way. The automatic method uses an hematology analyzer which functions to measure and examine blood cells in blood samples. Counting the number of platelets is done automatically by two methods, namely optical and impedance which have different principles. The optical method is based on cell size and morphology, while impedance is based on cell size only. Hypochrome is a condition where the Hb concentration is less than normal so that the central achromia widens (> 1/3 of the cell) and there is a decrease in the color of the erythrocytes, namely an increase in the diameter of the central pallor above normal so that it looks paler. Microcyte is a condition where the cell size is smaller than normal. The purpose of this study was to determine the difference in the number of platelets in the hematology analyzer using the impedance method and the optical method in the case of microcytic hypochromic anemia (based on erythrocyte index) with a descriptive analytical research design. The test used is the paired t-test with a total sample of 30 samples. The results of platelets using the impedance method have an average of 339.37 * 103 / uL with a standard deviation of 120.294. The results of platelets using the optical method have an average of 314.70 * 103 / uL with a standard deviation of 113.569. A significant value of 0.000 significant value of (sig. < 0.05) can be concluded that there is a difference between the results of platelets on the hematology analyzer using the impedance method and the optical method in cases of microcytic hypochromic anemia (based on erythrocyte index). Keywords : Trombosit, Hipokrom Mikrositer, Hematology analyzer, Impedance, Optik.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信