{"title":"万古霉素高分子材料种植体涂层的体外抗菌性能研究","authors":"Ali Alenezi","doi":"10.3390/surfaces6030022","DOIUrl":null,"url":null,"abstract":"Bacterial adhesion and biofilm formation on the surface of titanium implants are the main causes of implant-associated infection. An antibacterial coating on the implant surface can reduce the risk of biofilm formation. The aim of this study was to investigate the bactericidal effects of a van-comycin-loaded polymer coated on an implant surface. For this purpose, poly(N-isopropylacrylamide) (PNIPAAm) was first synthesized as a homopolymer or by co-polymerization with acrylamide (PNIPAAm-AAm) at a 5% weight ratio. Then, thin and uniform polymer coatings were prepared using the spin coating technique. The degree of surface hydro-philicity of the polymer coatings was evaluated by measuring the water contact angle (CA). For the antibacterial tests, the polymer-coated surfaces were loaded with vancomycin. The tests were performed in three conditions: on a glass surface (control), on a PNIPAAm-AAm-coated surface, and on a PNIPAAm-AAm-coated surface loaded with vancomycin. The death rates of the bacteria in contact with the coated surfaces were evaluated at different temperatures with fluorescence microscopy. A scanning electron microscopy (SEM) analysis of cross sections of the polymer coatings revealed a uniform thin film of approximately 200 nm in thickness. The water contact angle analysis performed at different temperatures revealed that the polymer-coated surfaces were more hydrophobic (CAs ranging between 53° and 63°) than the uncoated glass surface (CA ranging between 15° and 35°). The bacterial death rate, measured at 40 °C or while continuously switching the temperature between 37 °C and 40 °C, was higher in the presence of the surface coated with vancomycin-loaded PNIPAAm-AAm than when using the other surfaces (p-value ≤ 0.001). The vancomycin-loaded polymer coating evaluated in this study exhibited effective antibacterial properties when the polymer reached the phase transition temperature.","PeriodicalId":22129,"journal":{"name":"Surfaces","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Antibacterial Performance of Implant Coating Made of Vancomycin-Loaded Polymer Material: An In Vitro Study\",\"authors\":\"Ali Alenezi\",\"doi\":\"10.3390/surfaces6030022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bacterial adhesion and biofilm formation on the surface of titanium implants are the main causes of implant-associated infection. An antibacterial coating on the implant surface can reduce the risk of biofilm formation. The aim of this study was to investigate the bactericidal effects of a van-comycin-loaded polymer coated on an implant surface. For this purpose, poly(N-isopropylacrylamide) (PNIPAAm) was first synthesized as a homopolymer or by co-polymerization with acrylamide (PNIPAAm-AAm) at a 5% weight ratio. Then, thin and uniform polymer coatings were prepared using the spin coating technique. The degree of surface hydro-philicity of the polymer coatings was evaluated by measuring the water contact angle (CA). For the antibacterial tests, the polymer-coated surfaces were loaded with vancomycin. The tests were performed in three conditions: on a glass surface (control), on a PNIPAAm-AAm-coated surface, and on a PNIPAAm-AAm-coated surface loaded with vancomycin. The death rates of the bacteria in contact with the coated surfaces were evaluated at different temperatures with fluorescence microscopy. A scanning electron microscopy (SEM) analysis of cross sections of the polymer coatings revealed a uniform thin film of approximately 200 nm in thickness. The water contact angle analysis performed at different temperatures revealed that the polymer-coated surfaces were more hydrophobic (CAs ranging between 53° and 63°) than the uncoated glass surface (CA ranging between 15° and 35°). The bacterial death rate, measured at 40 °C or while continuously switching the temperature between 37 °C and 40 °C, was higher in the presence of the surface coated with vancomycin-loaded PNIPAAm-AAm than when using the other surfaces (p-value ≤ 0.001). The vancomycin-loaded polymer coating evaluated in this study exhibited effective antibacterial properties when the polymer reached the phase transition temperature.\",\"PeriodicalId\":22129,\"journal\":{\"name\":\"Surfaces\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surfaces\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/surfaces6030022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surfaces","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/surfaces6030022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Antibacterial Performance of Implant Coating Made of Vancomycin-Loaded Polymer Material: An In Vitro Study
Bacterial adhesion and biofilm formation on the surface of titanium implants are the main causes of implant-associated infection. An antibacterial coating on the implant surface can reduce the risk of biofilm formation. The aim of this study was to investigate the bactericidal effects of a van-comycin-loaded polymer coated on an implant surface. For this purpose, poly(N-isopropylacrylamide) (PNIPAAm) was first synthesized as a homopolymer or by co-polymerization with acrylamide (PNIPAAm-AAm) at a 5% weight ratio. Then, thin and uniform polymer coatings were prepared using the spin coating technique. The degree of surface hydro-philicity of the polymer coatings was evaluated by measuring the water contact angle (CA). For the antibacterial tests, the polymer-coated surfaces were loaded with vancomycin. The tests were performed in three conditions: on a glass surface (control), on a PNIPAAm-AAm-coated surface, and on a PNIPAAm-AAm-coated surface loaded with vancomycin. The death rates of the bacteria in contact with the coated surfaces were evaluated at different temperatures with fluorescence microscopy. A scanning electron microscopy (SEM) analysis of cross sections of the polymer coatings revealed a uniform thin film of approximately 200 nm in thickness. The water contact angle analysis performed at different temperatures revealed that the polymer-coated surfaces were more hydrophobic (CAs ranging between 53° and 63°) than the uncoated glass surface (CA ranging between 15° and 35°). The bacterial death rate, measured at 40 °C or while continuously switching the temperature between 37 °C and 40 °C, was higher in the presence of the surface coated with vancomycin-loaded PNIPAAm-AAm than when using the other surfaces (p-value ≤ 0.001). The vancomycin-loaded polymer coating evaluated in this study exhibited effective antibacterial properties when the polymer reached the phase transition temperature.