{"title":"全尺寸机械-生物处理(MBT)装置中城市垃圾生物稳定主要参数的变化","authors":"Justyna Koc-Jurczyk","doi":"10.2478/acee-2023-0043","DOIUrl":null,"url":null,"abstract":"Abstract Poland's mixed municipal waste management system has been based on mechanical-biological treatment (MBT). One of the MBT processes is the biological stabilisation of fractions of less than 80 mm. The final product after biological stabilisation is a stabiliser that, once the conditions required by law are met, can be landfilled. The stabilizer must meet the following requirements: the loss of ignition (LOI) of the stabiliser is less than 35% DM, the organic carbon content is less than 20% DM and the AT 4 value (aerobic 4-day respiration test) value is less than 10 mgO 2 /g DM. The study aimed to analyse the changes that occurred during the first 4 weeks of biological processing of the fraction of less than 80 mm of mixed municipal waste. The bioreactor feedstock consisted of 41.7% organic fraction (OF), the LOI was 32.3%, and the AT 4 value was 45.7 mgO 2 /g DM. During biological processing, at 4 weeks, the loss of OF in the total weight of the waste was found to be 22.6%, the losses after roasting decreased by almost 90% and the value of AT 4 was 6.6 mgO 2 /g DM. This means that the stabiliser already after 4 weeks, according to the law, could be sent to a landfill.","PeriodicalId":8117,"journal":{"name":"Architecture Civil Engineering Environment","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Changes in Main Parameters of Biological Stabilisation of Municipal Waste from a Full-Scale Mechanical-Biological Treatment (MBT) Installation\",\"authors\":\"Justyna Koc-Jurczyk\",\"doi\":\"10.2478/acee-2023-0043\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Poland's mixed municipal waste management system has been based on mechanical-biological treatment (MBT). One of the MBT processes is the biological stabilisation of fractions of less than 80 mm. The final product after biological stabilisation is a stabiliser that, once the conditions required by law are met, can be landfilled. The stabilizer must meet the following requirements: the loss of ignition (LOI) of the stabiliser is less than 35% DM, the organic carbon content is less than 20% DM and the AT 4 value (aerobic 4-day respiration test) value is less than 10 mgO 2 /g DM. The study aimed to analyse the changes that occurred during the first 4 weeks of biological processing of the fraction of less than 80 mm of mixed municipal waste. The bioreactor feedstock consisted of 41.7% organic fraction (OF), the LOI was 32.3%, and the AT 4 value was 45.7 mgO 2 /g DM. During biological processing, at 4 weeks, the loss of OF in the total weight of the waste was found to be 22.6%, the losses after roasting decreased by almost 90% and the value of AT 4 was 6.6 mgO 2 /g DM. This means that the stabiliser already after 4 weeks, according to the law, could be sent to a landfill.\",\"PeriodicalId\":8117,\"journal\":{\"name\":\"Architecture Civil Engineering Environment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Architecture Civil Engineering Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/acee-2023-0043\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Architecture Civil Engineering Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/acee-2023-0043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0
摘要
波兰的混合城市垃圾管理系统是基于机械生物处理(MBT)。其中一个MBT过程是小于80毫米的馏分的生物稳定。生物稳定后的最终产物是一种稳定剂,一旦满足法律要求的条件,就可以被填埋。稳定剂必须满足以下要求:稳定剂的燃失量(LOI)小于35% DM,有机碳含量小于20% DM, at4值(好氧4天呼吸试验)值小于10 mgO 2 /g DM。本研究旨在分析小于80 mm的混合城市垃圾部分在生物处理前4周发生的变化。41.7%的生物反应器原料由有机分数(的),LOI是32.3%,与4点值是45.7分别以2 / g DM。在生物处理过程中,在4周,损失的总重量的废物被发现22.6%,焙烧后的损失下降了几乎90%,4点的值是6.6分别以2 / g DM。这意味着稳定器已经4周后,根据法律,可能被送往垃圾填埋场。
Changes in Main Parameters of Biological Stabilisation of Municipal Waste from a Full-Scale Mechanical-Biological Treatment (MBT) Installation
Abstract Poland's mixed municipal waste management system has been based on mechanical-biological treatment (MBT). One of the MBT processes is the biological stabilisation of fractions of less than 80 mm. The final product after biological stabilisation is a stabiliser that, once the conditions required by law are met, can be landfilled. The stabilizer must meet the following requirements: the loss of ignition (LOI) of the stabiliser is less than 35% DM, the organic carbon content is less than 20% DM and the AT 4 value (aerobic 4-day respiration test) value is less than 10 mgO 2 /g DM. The study aimed to analyse the changes that occurred during the first 4 weeks of biological processing of the fraction of less than 80 mm of mixed municipal waste. The bioreactor feedstock consisted of 41.7% organic fraction (OF), the LOI was 32.3%, and the AT 4 value was 45.7 mgO 2 /g DM. During biological processing, at 4 weeks, the loss of OF in the total weight of the waste was found to be 22.6%, the losses after roasting decreased by almost 90% and the value of AT 4 was 6.6 mgO 2 /g DM. This means that the stabiliser already after 4 weeks, according to the law, could be sent to a landfill.