{"title":"上限压力和下限压力对液化石油气炉热性能的影响","authors":"Qudsiyyatul Lailiyah, Bayu Utomo, Himma Firdaus, Intan Paramudita, Nanang Kusnandar, Ihsan Supono, Iput Kasiyanto, Hidayat Wiriadinata","doi":"10.5109/7151722","DOIUrl":null,"url":null,"abstract":": The paper presents the effect of the LPG's upper and lower limit working pressure on the thermal performance of an LPG single-burner gas stove. The measurement method for determining LPG stove thermal performance is based on Indonesian National Standard (SNI). The recent standard is SNI 8660:2018 about low-pressure LPG and LNG/NG gas stoves for households. According to the SNI, the working pressure required by the standard is 280 ± 5 mmH 2 O (2.8 ± 0.05 kPa). In this study, the effect of gas stove thermal performance for the upper limit pressure was carried out at a working pressure of 290 mmH 2 O, and the lower limit pressure was carried out at a working pressure of 270 mmH 2 O. A regression method was applied to determine the effect of upper and lower limit pressure on the thermal performance standardization of single-burner gas stoves. At the 95% confidence level, the input pressure significantly affects the heat input but has no significant effect on the thermal efficiency. The results show that the range of input gas pressure on the heat input measurement is 280 ± 5 mmH 2 O with special attention to pressure stability, while the thermal efficiency measurement can expand to 280 ±","PeriodicalId":12085,"journal":{"name":"Evergreen","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Upper and Lower Limit Pressure on the Thermal Performance of Liquefied Petroleum Gas Stove\",\"authors\":\"Qudsiyyatul Lailiyah, Bayu Utomo, Himma Firdaus, Intan Paramudita, Nanang Kusnandar, Ihsan Supono, Iput Kasiyanto, Hidayat Wiriadinata\",\"doi\":\"10.5109/7151722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": The paper presents the effect of the LPG's upper and lower limit working pressure on the thermal performance of an LPG single-burner gas stove. The measurement method for determining LPG stove thermal performance is based on Indonesian National Standard (SNI). The recent standard is SNI 8660:2018 about low-pressure LPG and LNG/NG gas stoves for households. According to the SNI, the working pressure required by the standard is 280 ± 5 mmH 2 O (2.8 ± 0.05 kPa). In this study, the effect of gas stove thermal performance for the upper limit pressure was carried out at a working pressure of 290 mmH 2 O, and the lower limit pressure was carried out at a working pressure of 270 mmH 2 O. A regression method was applied to determine the effect of upper and lower limit pressure on the thermal performance standardization of single-burner gas stoves. At the 95% confidence level, the input pressure significantly affects the heat input but has no significant effect on the thermal efficiency. The results show that the range of input gas pressure on the heat input measurement is 280 ± 5 mmH 2 O with special attention to pressure stability, while the thermal efficiency measurement can expand to 280 ±\",\"PeriodicalId\":12085,\"journal\":{\"name\":\"Evergreen\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Evergreen\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5109/7151722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Environmental Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Evergreen","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5109/7151722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Environmental Science","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Upper and Lower Limit Pressure on the Thermal Performance of Liquefied Petroleum Gas Stove
: The paper presents the effect of the LPG's upper and lower limit working pressure on the thermal performance of an LPG single-burner gas stove. The measurement method for determining LPG stove thermal performance is based on Indonesian National Standard (SNI). The recent standard is SNI 8660:2018 about low-pressure LPG and LNG/NG gas stoves for households. According to the SNI, the working pressure required by the standard is 280 ± 5 mmH 2 O (2.8 ± 0.05 kPa). In this study, the effect of gas stove thermal performance for the upper limit pressure was carried out at a working pressure of 290 mmH 2 O, and the lower limit pressure was carried out at a working pressure of 270 mmH 2 O. A regression method was applied to determine the effect of upper and lower limit pressure on the thermal performance standardization of single-burner gas stoves. At the 95% confidence level, the input pressure significantly affects the heat input but has no significant effect on the thermal efficiency. The results show that the range of input gas pressure on the heat input measurement is 280 ± 5 mmH 2 O with special attention to pressure stability, while the thermal efficiency measurement can expand to 280 ±
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Evergreen
Evergreen Environmental Science-Management, Monitoring, Policy and Law
CiteScore
4.30
自引率
0.00%
发文量
99
期刊介绍: “Evergreen - Joint Journal of Novel Carbon Resource Sciences & Green Asia Strategy” is a refereed international open access online journal, serving researchers in academic and research organizations and all practitioners in the science and technology to contribute to the realization of Green Asia where ecology and economic growth coexist. The scope of the journal involves the aspects of science, technology, economic and social science. Namely, Novel Carbon Resource Sciences, Green Asia Strategy, and other fields related to Asian environment should be included in this journal. The journal aims to contribute to resolve or mitigate the global and local problems in Asia by bringing together new ideas and developments. The editors welcome good quality contributions from all over the Asia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信