{"title":"五层和十层混合连接预制混凝土特殊弯矩框架的抗震性能","authors":"Jimmy Chandra, Lokito V.N., Tambuna J.A.","doi":"10.9744/ced.25.2.85-95","DOIUrl":null,"url":null,"abstract":"Precast concrete has been widely implemented in various construction projects due to shorter construction duration and consistent quality. In a previous study, Solberg et al. (2008) conducted an experiment on hybrid beam-column connections with Damage Avoidance Design concept to improve the seismic performance of precast concrete special moment frames. The objective of this study is to further evaluate the seismic performance of precast concrete special moment frames with the hybrid beam-column connections in five and ten story buildings. The evaluation was done through non-linear dynamic time history analysis using OpenSees. The analysis results show that precast concrete frame buildings exhibit insignificant difference in maximum interstory drift ratios and roof displacements as compared to conventional concrete frame buildings. However, with significantly smaller residual displacements which indicates less structural damage, precast concrete frame buildings could be preferred in the long run as they require less structural repairs after a strong earthquake event.","PeriodicalId":30107,"journal":{"name":"Civil Engineering Dimension","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Seismic Performance of Precast Concrete Special Moment Frames with Hybrid Connection System in Five and Ten Story Buildings\",\"authors\":\"Jimmy Chandra, Lokito V.N., Tambuna J.A.\",\"doi\":\"10.9744/ced.25.2.85-95\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Precast concrete has been widely implemented in various construction projects due to shorter construction duration and consistent quality. In a previous study, Solberg et al. (2008) conducted an experiment on hybrid beam-column connections with Damage Avoidance Design concept to improve the seismic performance of precast concrete special moment frames. The objective of this study is to further evaluate the seismic performance of precast concrete special moment frames with the hybrid beam-column connections in five and ten story buildings. The evaluation was done through non-linear dynamic time history analysis using OpenSees. The analysis results show that precast concrete frame buildings exhibit insignificant difference in maximum interstory drift ratios and roof displacements as compared to conventional concrete frame buildings. However, with significantly smaller residual displacements which indicates less structural damage, precast concrete frame buildings could be preferred in the long run as they require less structural repairs after a strong earthquake event.\",\"PeriodicalId\":30107,\"journal\":{\"name\":\"Civil Engineering Dimension\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Civil Engineering Dimension\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9744/ced.25.2.85-95\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil Engineering Dimension","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9744/ced.25.2.85-95","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
预制混凝土因其工期短、质量稳定等优点,在各种建筑工程中得到了广泛的应用。在之前的研究中,Solberg et al.(2008)为了提高预制混凝土特殊弯矩框架的抗震性能,在避免损伤设计理念下对混合梁柱连接进行了实验。本研究的目的是进一步评估五层和十层建筑中混合梁柱连接的预制混凝土特殊弯矩框架的抗震性能。通过使用OpenSees进行非线性动态时程分析来进行评估。分析结果表明,预制混凝土框架建筑与常规混凝土框架建筑相比,最大层间位移比和顶板位移差异不显著。然而,由于残余位移明显较小,表明结构损坏较少,从长远来看,预制混凝土框架建筑可能是首选,因为它们在强烈地震事件后需要较少的结构修复。
Seismic Performance of Precast Concrete Special Moment Frames with Hybrid Connection System in Five and Ten Story Buildings
Precast concrete has been widely implemented in various construction projects due to shorter construction duration and consistent quality. In a previous study, Solberg et al. (2008) conducted an experiment on hybrid beam-column connections with Damage Avoidance Design concept to improve the seismic performance of precast concrete special moment frames. The objective of this study is to further evaluate the seismic performance of precast concrete special moment frames with the hybrid beam-column connections in five and ten story buildings. The evaluation was done through non-linear dynamic time history analysis using OpenSees. The analysis results show that precast concrete frame buildings exhibit insignificant difference in maximum interstory drift ratios and roof displacements as compared to conventional concrete frame buildings. However, with significantly smaller residual displacements which indicates less structural damage, precast concrete frame buildings could be preferred in the long run as they require less structural repairs after a strong earthquake event.