None Dr Anamika Abraham, None Dr. Angleena Y Daniel, None Dr. Achsah Ann Thomas
{"title":"使用硅胶基质系统修复磨损的覆盖义齿附著体:一例报告","authors":"None Dr Anamika Abraham, None Dr. Angleena Y Daniel, None Dr. Achsah Ann Thomas","doi":"10.21276/ujds.2023.9.3.15","DOIUrl":null,"url":null,"abstract":"The case report discusses the use of a silicone matrix system for salvaging worn-out overdenture attachments in one-piece implant cases. It highlights the effectiveness of this technique and presents a detailed case study. One-piece or single-piece implant systems, where the intraosseous and abutment portions with the stud attachments consist of one unit, do not allow changing the worn-out abutment individually if required, thus ruling out any further use of implant and abutment once the attachment component faces extensive irreversible wearing. The ‘Retention. Sil’ – an additional curing elastomeric material in salvaging worn-out attachments of one-piece implants, emphasizes the revitalization process and effective use as an attachment for implant-retained overdenture, thereby extending the clinical use of one-piece implants and avoiding extensive invasive procedures in geriatric patients.","PeriodicalId":100856,"journal":{"name":"King Saud University Journal of Dental Sciences","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Revitalizing Worn-Out Overdenture Attachments in One-Piece Implant Cases using Silicone Matrix System: A Case Report\",\"authors\":\"None Dr Anamika Abraham, None Dr. Angleena Y Daniel, None Dr. Achsah Ann Thomas\",\"doi\":\"10.21276/ujds.2023.9.3.15\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The case report discusses the use of a silicone matrix system for salvaging worn-out overdenture attachments in one-piece implant cases. It highlights the effectiveness of this technique and presents a detailed case study. One-piece or single-piece implant systems, where the intraosseous and abutment portions with the stud attachments consist of one unit, do not allow changing the worn-out abutment individually if required, thus ruling out any further use of implant and abutment once the attachment component faces extensive irreversible wearing. The ‘Retention. Sil’ – an additional curing elastomeric material in salvaging worn-out attachments of one-piece implants, emphasizes the revitalization process and effective use as an attachment for implant-retained overdenture, thereby extending the clinical use of one-piece implants and avoiding extensive invasive procedures in geriatric patients.\",\"PeriodicalId\":100856,\"journal\":{\"name\":\"King Saud University Journal of Dental Sciences\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"King Saud University Journal of Dental Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21276/ujds.2023.9.3.15\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"King Saud University Journal of Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21276/ujds.2023.9.3.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Revitalizing Worn-Out Overdenture Attachments in One-Piece Implant Cases using Silicone Matrix System: A Case Report
The case report discusses the use of a silicone matrix system for salvaging worn-out overdenture attachments in one-piece implant cases. It highlights the effectiveness of this technique and presents a detailed case study. One-piece or single-piece implant systems, where the intraosseous and abutment portions with the stud attachments consist of one unit, do not allow changing the worn-out abutment individually if required, thus ruling out any further use of implant and abutment once the attachment component faces extensive irreversible wearing. The ‘Retention. Sil’ – an additional curing elastomeric material in salvaging worn-out attachments of one-piece implants, emphasizes the revitalization process and effective use as an attachment for implant-retained overdenture, thereby extending the clinical use of one-piece implants and avoiding extensive invasive procedures in geriatric patients.