{"title":"在现有的工业回用污水处理厂使用超滤进行三级处理-一种使用不确定性估计的人工神经网络建模方法","authors":"D. Ramkumar, Vinayakam Jothiprakash","doi":"10.2166/wrd.2023.179","DOIUrl":null,"url":null,"abstract":"Abstract Navi Mumbai Municipal Corporation of Maharashtra state, India, unified a tertiary treatment plant (TTP) of 20 million litres per day (MLD) capacity with ultrafiltration technology in an existing Koparkhairane sewage treatment plant (STP) for producing effluent quality usable for industrial purposes. As prior art, an artificial neural network-genetic algorithm (ANN-GA) along with uncertainty estimation using prediction interval is employed to model secondary treated effluent (STE) flow rate (QT) and other quality parameters such as biochemical oxygen demand, chemical oxygen demand, and total suspended solids (TSS) to conclude the reliability of the range in which the input available to TTP. ANN-GA model provides a coefficient of determination above 0.90 for all STE parameters modelled other than TSS. Inferring that a good quantity and quality of 20 MLD STP treated water is currently available, where a decreasing trend of QT is also noticed and highlighted. Further, the Wilcoxon signed-rank test on the quality parameter of effluent TTP for industrial reuse standard infers TSS shows infringement during the initial period but started adhering to standards over time. The research delineates at the outset of exploring water reuse policy in India, emphasizing Maharashtra state, modelling STE using ANN-GA and performance evaluation of TTP.","PeriodicalId":34727,"journal":{"name":"Water Reuse","volume":"1 1","pages":"0"},"PeriodicalIF":4.3000,"publicationDate":"2023-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tertiary treatment using ultrafiltration in an existing sewage treatment plant for industrial reuse – a modelling approach using an artificial neural network with uncertainty estimation\",\"authors\":\"D. Ramkumar, Vinayakam Jothiprakash\",\"doi\":\"10.2166/wrd.2023.179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Navi Mumbai Municipal Corporation of Maharashtra state, India, unified a tertiary treatment plant (TTP) of 20 million litres per day (MLD) capacity with ultrafiltration technology in an existing Koparkhairane sewage treatment plant (STP) for producing effluent quality usable for industrial purposes. As prior art, an artificial neural network-genetic algorithm (ANN-GA) along with uncertainty estimation using prediction interval is employed to model secondary treated effluent (STE) flow rate (QT) and other quality parameters such as biochemical oxygen demand, chemical oxygen demand, and total suspended solids (TSS) to conclude the reliability of the range in which the input available to TTP. ANN-GA model provides a coefficient of determination above 0.90 for all STE parameters modelled other than TSS. Inferring that a good quantity and quality of 20 MLD STP treated water is currently available, where a decreasing trend of QT is also noticed and highlighted. Further, the Wilcoxon signed-rank test on the quality parameter of effluent TTP for industrial reuse standard infers TSS shows infringement during the initial period but started adhering to standards over time. The research delineates at the outset of exploring water reuse policy in India, emphasizing Maharashtra state, modelling STE using ANN-GA and performance evaluation of TTP.\",\"PeriodicalId\":34727,\"journal\":{\"name\":\"Water Reuse\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Water Reuse\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/wrd.2023.179\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Reuse","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/wrd.2023.179","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
Tertiary treatment using ultrafiltration in an existing sewage treatment plant for industrial reuse – a modelling approach using an artificial neural network with uncertainty estimation
Abstract Navi Mumbai Municipal Corporation of Maharashtra state, India, unified a tertiary treatment plant (TTP) of 20 million litres per day (MLD) capacity with ultrafiltration technology in an existing Koparkhairane sewage treatment plant (STP) for producing effluent quality usable for industrial purposes. As prior art, an artificial neural network-genetic algorithm (ANN-GA) along with uncertainty estimation using prediction interval is employed to model secondary treated effluent (STE) flow rate (QT) and other quality parameters such as biochemical oxygen demand, chemical oxygen demand, and total suspended solids (TSS) to conclude the reliability of the range in which the input available to TTP. ANN-GA model provides a coefficient of determination above 0.90 for all STE parameters modelled other than TSS. Inferring that a good quantity and quality of 20 MLD STP treated water is currently available, where a decreasing trend of QT is also noticed and highlighted. Further, the Wilcoxon signed-rank test on the quality parameter of effluent TTP for industrial reuse standard infers TSS shows infringement during the initial period but started adhering to standards over time. The research delineates at the outset of exploring water reuse policy in India, emphasizing Maharashtra state, modelling STE using ANN-GA and performance evaluation of TTP.