{"title":"放射性示踪剂在工业浮选回路中测定进料流量不平衡和粒度偏析的应用","authors":"Nelson Andres Barrientos, Francico Diaz","doi":"10.37190/ppmp/174817","DOIUrl":null,"url":null,"abstract":"This publication presents the application of radiotracers in the characterization of industrial flotation circuits. Two examples are showcased: the detection of feed flow rate imbalances and the characterization of particle size segregation in automatic mineral-cutting machines. The feed pulp distribution was determined from the mean residence times. Particle size segregation was measured by sampling the cutting machines (≅ 25 grams samples) using coarse, intermediate, and fine-sized radiotracer particles. Radiotracers were injected into the feed streams and measured at various points of the circuit using nuclear instruments, allowing for non-invasive and real time detection. Results show that in the rougher flotation stage, the feed flow is distributed almost evenly in lines 2 and 3 (approximately 38% of the flow goes to each line) and to a lesser extent towards line 4 (approximately 24%). In lines 1 and 2 of the scavenger stage, a higher percentage of the flow goes towards line 1 (approximately 59%) and a lower percentage towards line 2 (41%). Line 6 of the rougher flotation is the fastest of the circuit (shortest residence time). In addition, the inlet mineral-cutting machine of the rougher stage segregates particles with a bias for fine sizes (11.4 % more fine-sized particles than coarse ones). This work is an example of how radiotracer technology can be applied to improve metal production and processes. Radiotracers provide reliable information to be used in combination with other metallurgical data to properly assess flotation circuits.","PeriodicalId":49137,"journal":{"name":"Physicochemical Problems of Mineral Processing","volume":"12 1","pages":"0"},"PeriodicalIF":1.3000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of radiotracers as tools to determine feed flowrate imbalances and particle size segregation in industrial flotation circuits\",\"authors\":\"Nelson Andres Barrientos, Francico Diaz\",\"doi\":\"10.37190/ppmp/174817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This publication presents the application of radiotracers in the characterization of industrial flotation circuits. Two examples are showcased: the detection of feed flow rate imbalances and the characterization of particle size segregation in automatic mineral-cutting machines. The feed pulp distribution was determined from the mean residence times. Particle size segregation was measured by sampling the cutting machines (≅ 25 grams samples) using coarse, intermediate, and fine-sized radiotracer particles. Radiotracers were injected into the feed streams and measured at various points of the circuit using nuclear instruments, allowing for non-invasive and real time detection. Results show that in the rougher flotation stage, the feed flow is distributed almost evenly in lines 2 and 3 (approximately 38% of the flow goes to each line) and to a lesser extent towards line 4 (approximately 24%). In lines 1 and 2 of the scavenger stage, a higher percentage of the flow goes towards line 1 (approximately 59%) and a lower percentage towards line 2 (41%). Line 6 of the rougher flotation is the fastest of the circuit (shortest residence time). In addition, the inlet mineral-cutting machine of the rougher stage segregates particles with a bias for fine sizes (11.4 % more fine-sized particles than coarse ones). This work is an example of how radiotracer technology can be applied to improve metal production and processes. Radiotracers provide reliable information to be used in combination with other metallurgical data to properly assess flotation circuits.\",\"PeriodicalId\":49137,\"journal\":{\"name\":\"Physicochemical Problems of Mineral Processing\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physicochemical Problems of Mineral Processing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37190/ppmp/174817\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physicochemical Problems of Mineral Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37190/ppmp/174817","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
Application of radiotracers as tools to determine feed flowrate imbalances and particle size segregation in industrial flotation circuits
This publication presents the application of radiotracers in the characterization of industrial flotation circuits. Two examples are showcased: the detection of feed flow rate imbalances and the characterization of particle size segregation in automatic mineral-cutting machines. The feed pulp distribution was determined from the mean residence times. Particle size segregation was measured by sampling the cutting machines (≅ 25 grams samples) using coarse, intermediate, and fine-sized radiotracer particles. Radiotracers were injected into the feed streams and measured at various points of the circuit using nuclear instruments, allowing for non-invasive and real time detection. Results show that in the rougher flotation stage, the feed flow is distributed almost evenly in lines 2 and 3 (approximately 38% of the flow goes to each line) and to a lesser extent towards line 4 (approximately 24%). In lines 1 and 2 of the scavenger stage, a higher percentage of the flow goes towards line 1 (approximately 59%) and a lower percentage towards line 2 (41%). Line 6 of the rougher flotation is the fastest of the circuit (shortest residence time). In addition, the inlet mineral-cutting machine of the rougher stage segregates particles with a bias for fine sizes (11.4 % more fine-sized particles than coarse ones). This work is an example of how radiotracer technology can be applied to improve metal production and processes. Radiotracers provide reliable information to be used in combination with other metallurgical data to properly assess flotation circuits.
期刊介绍:
Physicochemical Problems of Mineral Processing is an international, open access journal which covers theoretical approaches and their practical applications in all aspects of mineral processing and extractive metallurgy.
Criteria for publication in the Physicochemical Problems of Mineral Processing journal are novelty, quality and current interest. Manuscripts which only make routine use of minor extensions to well established methodologies are not appropriate for the journal.
Topics of interest
Analytical techniques and applied mineralogy
Computer applications
Comminution, classification and sorting
Froth flotation
Solid-liquid separation
Gravity concentration
Magnetic and electric separation
Hydro and biohydrometallurgy
Extractive metallurgy
Recycling and mineral wastes
Environmental aspects of mineral processing
and other mineral processing related subjects.