混合分布式发电系统零功率失配孤岛检测算法

Sareddy Venkata Rami Reddy, T. R. Premila, Ch. Rami Reddy, B. Nagi Reddy
{"title":"混合分布式发电系统零功率失配孤岛检测算法","authors":"Sareddy Venkata Rami Reddy, T. R. Premila, Ch. Rami Reddy, B. Nagi Reddy","doi":"10.32397/tesea.vol4.n2.534","DOIUrl":null,"url":null,"abstract":"Distributed generation is essential for both keeping up with the rising power demand and reducing the amount of money spent on fossil fuels. There is widespread agreement that the world should prioritize the development of renewable energy systems such as wind and solar energy. This study describes the design and utility-grid integration of a hybrid distributed generating system that utilizes photovoltaic and wind-driven permanent magnet synchronous generators (hybrid PMSG-PV systems). To prevent damage to the grid, hybrid distributed generation systems, consumer devices, and line workers must be protected from islanding. Detection of islanding in hybrid DG systems has been suggested using passive islanding and time-spectral analysis. Measuring and amplifying the ripple content present in voltage at point of common coupling (PCC) about 0.4 seconds after the permissible delay time after the circuit breaker opens on the utility grid side is how islanding is discovered using this method. Compared to other methods, the proposed method has smoother islanding detection waveforms owing to increases in both the window size and threshold limit. The suggested method detects islanding in 40 ms and is verified in a variety of non-islanding scenarios, such as fault occurrence, parallel feeder loss, and load shift. In addition, the cost is reduced, the response time is rapid, and there is no non-detection zone (NDZ) when using these methods. Unlike active islanding detection methods, their function is unaffected by the size, quantity, or type of distributed generators linked to the utility grid; hence, there are no power quality concerns.","PeriodicalId":499536,"journal":{"name":"TESEA, transactions on energy systems and engineering applications","volume":"220 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Zero power mismatch islanding detection algorithm for hybrid distributed generating system\",\"authors\":\"Sareddy Venkata Rami Reddy, T. R. Premila, Ch. Rami Reddy, B. Nagi Reddy\",\"doi\":\"10.32397/tesea.vol4.n2.534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distributed generation is essential for both keeping up with the rising power demand and reducing the amount of money spent on fossil fuels. There is widespread agreement that the world should prioritize the development of renewable energy systems such as wind and solar energy. This study describes the design and utility-grid integration of a hybrid distributed generating system that utilizes photovoltaic and wind-driven permanent magnet synchronous generators (hybrid PMSG-PV systems). To prevent damage to the grid, hybrid distributed generation systems, consumer devices, and line workers must be protected from islanding. Detection of islanding in hybrid DG systems has been suggested using passive islanding and time-spectral analysis. Measuring and amplifying the ripple content present in voltage at point of common coupling (PCC) about 0.4 seconds after the permissible delay time after the circuit breaker opens on the utility grid side is how islanding is discovered using this method. Compared to other methods, the proposed method has smoother islanding detection waveforms owing to increases in both the window size and threshold limit. The suggested method detects islanding in 40 ms and is verified in a variety of non-islanding scenarios, such as fault occurrence, parallel feeder loss, and load shift. In addition, the cost is reduced, the response time is rapid, and there is no non-detection zone (NDZ) when using these methods. Unlike active islanding detection methods, their function is unaffected by the size, quantity, or type of distributed generators linked to the utility grid; hence, there are no power quality concerns.\",\"PeriodicalId\":499536,\"journal\":{\"name\":\"TESEA, transactions on energy systems and engineering applications\",\"volume\":\"220 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TESEA, transactions on energy systems and engineering applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32397/tesea.vol4.n2.534\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TESEA, transactions on energy systems and engineering applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32397/tesea.vol4.n2.534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

分布式发电对于满足不断增长的电力需求和减少在化石燃料上的花费至关重要。人们普遍认为,世界应该优先发展风能和太阳能等可再生能源系统。本研究描述了利用光伏和风力驱动的永磁同步发电机(混合PMSG-PV系统)的混合分布式发电系统的设计和公用事业电网整合。为了防止对电网的破坏,必须保护混合分布式发电系统、消费设备和线路工作人员免受孤岛。建议采用被动孤岛和时间谱分析方法检测混合DG系统中的孤岛。在公共电网侧的断路器打开后,在允许的延迟时间后约0.4秒,测量和放大在共耦合点(PCC)电压中存在的纹波含量是如何使用该方法发现孤岛的。与其他方法相比,由于窗口大小和阈值限制的增加,该方法具有更平滑的孤岛检测波形。该方法在40 ms内检测到孤岛,并在故障发生、并联馈线损耗和负载移位等多种非孤岛场景下进行了验证。此外,在使用这些方法时,成本降低,响应时间快,并且没有非检测区(NDZ)。与主动孤岛检测方法不同,它们的功能不受连接到公用电网的分布式发电机的大小、数量或类型的影响;因此,不存在电能质量问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Zero power mismatch islanding detection algorithm for hybrid distributed generating system
Distributed generation is essential for both keeping up with the rising power demand and reducing the amount of money spent on fossil fuels. There is widespread agreement that the world should prioritize the development of renewable energy systems such as wind and solar energy. This study describes the design and utility-grid integration of a hybrid distributed generating system that utilizes photovoltaic and wind-driven permanent magnet synchronous generators (hybrid PMSG-PV systems). To prevent damage to the grid, hybrid distributed generation systems, consumer devices, and line workers must be protected from islanding. Detection of islanding in hybrid DG systems has been suggested using passive islanding and time-spectral analysis. Measuring and amplifying the ripple content present in voltage at point of common coupling (PCC) about 0.4 seconds after the permissible delay time after the circuit breaker opens on the utility grid side is how islanding is discovered using this method. Compared to other methods, the proposed method has smoother islanding detection waveforms owing to increases in both the window size and threshold limit. The suggested method detects islanding in 40 ms and is verified in a variety of non-islanding scenarios, such as fault occurrence, parallel feeder loss, and load shift. In addition, the cost is reduced, the response time is rapid, and there is no non-detection zone (NDZ) when using these methods. Unlike active islanding detection methods, their function is unaffected by the size, quantity, or type of distributed generators linked to the utility grid; hence, there are no power quality concerns.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信