{"title":"基于神经网络技术的住宅空调负荷分析","authors":"Mitali Ray, Lohit Kumar Sahoo","doi":"10.52549/ijeei.v11i3.4607","DOIUrl":null,"url":null,"abstract":"The process of limiting the amount of energy that is utilized is known as energy conservation. This can be accomplished by making more effective use of the energy that is available. As a result, there is a requirement for more effective management of the consumption of energy in buildings. It is essential to have an accurate load calculation for a residential building because the loads for heating and cooling add up a significant portion of the total building loads. In this study, the load analysis of the HVAC (Heating, Ventilation, and Air Conditioning) system in a residential building was carried out by taking into consideration three different neural networks. These networks are known as the feed forward network, the cascaded forward back propagation network, and the Elman back propagation network. During the process of conducting a load study of the heating and cooling loads on an HVAC system, performance measurements like MAE (mean absolute error), MSE (mean square error), MRE (mean relative error), and MAPE (mean absolute percentage error) are taken into consideration. It has been discovered that the cascaded forward back propagation method is the most effective method, with MAE, MSE, MRE, and MAPE values of 0.08, 0.0336, 0.0051, and 0.51% respectively for heating load and MAE, MSE, MRE, and MAPE values of 0.0975, 0.0406, 0.0053, and 0.53% respectively for cooling load.","PeriodicalId":37618,"journal":{"name":"Indonesian Journal of Electrical Engineering and Informatics","volume":"87 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"HVAC Load Analysis of Residential Building Using ANN Techniques\",\"authors\":\"Mitali Ray, Lohit Kumar Sahoo\",\"doi\":\"10.52549/ijeei.v11i3.4607\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The process of limiting the amount of energy that is utilized is known as energy conservation. This can be accomplished by making more effective use of the energy that is available. As a result, there is a requirement for more effective management of the consumption of energy in buildings. It is essential to have an accurate load calculation for a residential building because the loads for heating and cooling add up a significant portion of the total building loads. In this study, the load analysis of the HVAC (Heating, Ventilation, and Air Conditioning) system in a residential building was carried out by taking into consideration three different neural networks. These networks are known as the feed forward network, the cascaded forward back propagation network, and the Elman back propagation network. During the process of conducting a load study of the heating and cooling loads on an HVAC system, performance measurements like MAE (mean absolute error), MSE (mean square error), MRE (mean relative error), and MAPE (mean absolute percentage error) are taken into consideration. It has been discovered that the cascaded forward back propagation method is the most effective method, with MAE, MSE, MRE, and MAPE values of 0.08, 0.0336, 0.0051, and 0.51% respectively for heating load and MAE, MSE, MRE, and MAPE values of 0.0975, 0.0406, 0.0053, and 0.53% respectively for cooling load.\",\"PeriodicalId\":37618,\"journal\":{\"name\":\"Indonesian Journal of Electrical Engineering and Informatics\",\"volume\":\"87 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indonesian Journal of Electrical Engineering and Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52549/ijeei.v11i3.4607\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Electrical Engineering and Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52549/ijeei.v11i3.4607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Mathematics","Score":null,"Total":0}
HVAC Load Analysis of Residential Building Using ANN Techniques
The process of limiting the amount of energy that is utilized is known as energy conservation. This can be accomplished by making more effective use of the energy that is available. As a result, there is a requirement for more effective management of the consumption of energy in buildings. It is essential to have an accurate load calculation for a residential building because the loads for heating and cooling add up a significant portion of the total building loads. In this study, the load analysis of the HVAC (Heating, Ventilation, and Air Conditioning) system in a residential building was carried out by taking into consideration three different neural networks. These networks are known as the feed forward network, the cascaded forward back propagation network, and the Elman back propagation network. During the process of conducting a load study of the heating and cooling loads on an HVAC system, performance measurements like MAE (mean absolute error), MSE (mean square error), MRE (mean relative error), and MAPE (mean absolute percentage error) are taken into consideration. It has been discovered that the cascaded forward back propagation method is the most effective method, with MAE, MSE, MRE, and MAPE values of 0.08, 0.0336, 0.0051, and 0.51% respectively for heating load and MAE, MSE, MRE, and MAPE values of 0.0975, 0.0406, 0.0053, and 0.53% respectively for cooling load.
期刊介绍:
The journal publishes original papers in the field of electrical, computer and informatics engineering which covers, but not limited to, the following scope: Electronics: Electronic Materials, Microelectronic System, Design and Implementation of Application Specific Integrated Circuits (ASIC), VLSI Design, System-on-a-Chip (SoC) and Electronic Instrumentation Using CAD Tools, digital signal & data Processing, , Biomedical Transducers and instrumentation. Electrical: Electrical Engineering Materials, Electric Power Generation, Transmission and Distribution, Power Electronics, Power Quality, Power Economic, FACTS, Renewable Energy, Electric Traction. Telecommunication: Modulation and Signal Processing for Telecommunication, Information Theory and Coding, Antenna and Wave Propagation, Wireless and Mobile Communications, Radio Communication, Communication Electronics and Microwave, Radar Imaging. Control: Optimal, Robust and Adaptive Controls, Non Linear and Stochastic Controls, Modeling and Identification, Robotics, Image Based Control, Hybrid and Switching Control, Process Optimization and Scheduling, Control and Intelligent Systems. Computer and Informatics: Computer Architecture, Parallel and Distributed Computer, Pervasive Computing, Computer Network, Embedded System, Human—Computer Interaction, Virtual/Augmented Reality, Computer Security, Software Engineering (Software: Lifecycle, Management, Engineering Process, Engineering Tools and Methods), Programming (Programming Methodology and Paradigm), Data Engineering (Data and Knowledge level Modeling, Information Management (DB) practices, Knowledge Based Management System, Knowledge Discovery in Data).