{"title":"基于相量测量单元的可再生电力系统可靠性指标","authors":"Guglielmo Frigo, Federica Costa, Federico Grasso-Toro","doi":"10.21014/actaimeko.v12i3.1446","DOIUrl":null,"url":null,"abstract":"The fast growing of renewable energy sources is threatening the correct functioning of power systems, both at the transmission and distribution levels where the presence of converter-interfaced generation (CIG) is rapidly increasing. Phasor Measurement Units (PMUs) are widely known devices that can enhance power systems observability; however, their in-field performances are still compromised for what concerns low-inertia and fast transient conditions produced by contingencies. This paper presents a new metric that is able to quantify the discrepancy between the acquired signal and the reconstruction based on the PMU estimates. More specifically, the correspondence between this metric and one of the PMU settings, namely the reporting rate, is examined. This study is carried out in four different scenarios all characterized by a strong presence of distributed CIG, installed at either distribution or transmission levels. The results indicate the significance of evaluating not only such quantity for correct control but also the importance of the choice of the PMU settings in order to maintain proper control.","PeriodicalId":37987,"journal":{"name":"Acta IMEKO","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Phasor measurement unit based based reliability index for renewable-based power systems\",\"authors\":\"Guglielmo Frigo, Federica Costa, Federico Grasso-Toro\",\"doi\":\"10.21014/actaimeko.v12i3.1446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The fast growing of renewable energy sources is threatening the correct functioning of power systems, both at the transmission and distribution levels where the presence of converter-interfaced generation (CIG) is rapidly increasing. Phasor Measurement Units (PMUs) are widely known devices that can enhance power systems observability; however, their in-field performances are still compromised for what concerns low-inertia and fast transient conditions produced by contingencies. This paper presents a new metric that is able to quantify the discrepancy between the acquired signal and the reconstruction based on the PMU estimates. More specifically, the correspondence between this metric and one of the PMU settings, namely the reporting rate, is examined. This study is carried out in four different scenarios all characterized by a strong presence of distributed CIG, installed at either distribution or transmission levels. The results indicate the significance of evaluating not only such quantity for correct control but also the importance of the choice of the PMU settings in order to maintain proper control.\",\"PeriodicalId\":37987,\"journal\":{\"name\":\"Acta IMEKO\",\"volume\":\"34 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta IMEKO\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21014/actaimeko.v12i3.1446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta IMEKO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21014/actaimeko.v12i3.1446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Phasor measurement unit based based reliability index for renewable-based power systems
The fast growing of renewable energy sources is threatening the correct functioning of power systems, both at the transmission and distribution levels where the presence of converter-interfaced generation (CIG) is rapidly increasing. Phasor Measurement Units (PMUs) are widely known devices that can enhance power systems observability; however, their in-field performances are still compromised for what concerns low-inertia and fast transient conditions produced by contingencies. This paper presents a new metric that is able to quantify the discrepancy between the acquired signal and the reconstruction based on the PMU estimates. More specifically, the correspondence between this metric and one of the PMU settings, namely the reporting rate, is examined. This study is carried out in four different scenarios all characterized by a strong presence of distributed CIG, installed at either distribution or transmission levels. The results indicate the significance of evaluating not only such quantity for correct control but also the importance of the choice of the PMU settings in order to maintain proper control.
期刊介绍:
The main goal of this journal is the enhancement of academic activities of IMEKO and a wider dissemination of scientific output from IMEKO TC events. High-quality papers presented at IMEKO conferences, workshops or congresses are seleted by the event organizers and the authors are invited to publish an enhanced version of their paper in this journal. The journal also publishes scientific articles on measurement and instrumentation not related to an IMEKO event.