{"title":"幂律流体流动结构对Taylor-Couette构型杀菌消毒的影响","authors":"Feriel Hasballaoui, Samir Khali, Rachid Nebbali, Abderrahmane Zidane","doi":"10.1115/1.4063851","DOIUrl":null,"url":null,"abstract":"Abstract Fluid disinfection involving ultraviolet rays (UV) is a promising method due to its easy implementation and low cost compared to other methods. In the present work, fluid disinfection in a Taylor-Couette configuration operating with power-law fluids with different absorbance coefficients,and fluence rates were simulated using the Lattice Boltzmann Method. The effects of operating parameters such as Taylor and axial Reynolds numbers, power-law index behavior, and fluence rate were analyzed. Results show that the required UV dose decreases for an increase in absorbance coefficient, while it grows for increasing power-law indexes. For T a = 120 and Re = 3, the disinfection reaches 82.3% for pseudo-plastic fluids and is complete for dilatant fluids. Considering different absorbance coefficients, it was observed that a = 0.4 leads to complete disinfection regardless of the fluid. For a = 0.5, fluid disinfection is complete for the dilatant fluid only. A value of 0.6 leads to partial disinfection (~90%) for all fluids.","PeriodicalId":54833,"journal":{"name":"Journal of Fluids Engineering-Transactions of the Asme","volume":"99 22","pages":"0"},"PeriodicalIF":1.8000,"publicationDate":"2023-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect Of Power-Law Fluids Flow Structures On Germicides Disinfection Through Taylor-Couette Configuration\",\"authors\":\"Feriel Hasballaoui, Samir Khali, Rachid Nebbali, Abderrahmane Zidane\",\"doi\":\"10.1115/1.4063851\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Fluid disinfection involving ultraviolet rays (UV) is a promising method due to its easy implementation and low cost compared to other methods. In the present work, fluid disinfection in a Taylor-Couette configuration operating with power-law fluids with different absorbance coefficients,and fluence rates were simulated using the Lattice Boltzmann Method. The effects of operating parameters such as Taylor and axial Reynolds numbers, power-law index behavior, and fluence rate were analyzed. Results show that the required UV dose decreases for an increase in absorbance coefficient, while it grows for increasing power-law indexes. For T a = 120 and Re = 3, the disinfection reaches 82.3% for pseudo-plastic fluids and is complete for dilatant fluids. Considering different absorbance coefficients, it was observed that a = 0.4 leads to complete disinfection regardless of the fluid. For a = 0.5, fluid disinfection is complete for the dilatant fluid only. A value of 0.6 leads to partial disinfection (~90%) for all fluids.\",\"PeriodicalId\":54833,\"journal\":{\"name\":\"Journal of Fluids Engineering-Transactions of the Asme\",\"volume\":\"99 22\",\"pages\":\"0\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Fluids Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063851\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Fluids Engineering-Transactions of the Asme","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4063851","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要与其他方法相比,采用紫外线(UV)进行液体消毒具有操作简单、成本低等优点,是一种很有前途的方法。在本工作中,使用格子玻尔兹曼方法模拟了具有不同吸光度系数和通量率的幂律流体在Taylor-Couette配置中的流体消毒。分析了泰勒雷诺数、轴向雷诺数、幂律折射率行为和流量等操作参数的影响。结果表明,随着吸光度系数的增加,所需紫外线剂量减小,而随着幂律指数的增加,所需紫外线剂量增大。当t_a = 120, Re = 3时,拟塑性流体消毒效果达到82.3%,膨胀流体消毒效果完全。考虑不同吸光度系数,无论采用何种液体,a = 0.4均可达到完全消毒。当a = 0.5时,仅对膨胀液消毒完成。值为0.6导致所有液体部分消毒(~90%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect Of Power-Law Fluids Flow Structures On Germicides Disinfection Through Taylor-Couette Configuration
Abstract Fluid disinfection involving ultraviolet rays (UV) is a promising method due to its easy implementation and low cost compared to other methods. In the present work, fluid disinfection in a Taylor-Couette configuration operating with power-law fluids with different absorbance coefficients,and fluence rates were simulated using the Lattice Boltzmann Method. The effects of operating parameters such as Taylor and axial Reynolds numbers, power-law index behavior, and fluence rate were analyzed. Results show that the required UV dose decreases for an increase in absorbance coefficient, while it grows for increasing power-law indexes. For T a = 120 and Re = 3, the disinfection reaches 82.3% for pseudo-plastic fluids and is complete for dilatant fluids. Considering different absorbance coefficients, it was observed that a = 0.4 leads to complete disinfection regardless of the fluid. For a = 0.5, fluid disinfection is complete for the dilatant fluid only. A value of 0.6 leads to partial disinfection (~90%) for all fluids.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
10.00%
发文量
165
审稿时长
5.0 months
期刊介绍: Multiphase flows; Pumps; Aerodynamics; Boundary layers; Bubbly flows; Cavitation; Compressible flows; Convective heat/mass transfer as it is affected by fluid flow; Duct and pipe flows; Free shear layers; Flows in biological systems; Fluid-structure interaction; Fluid transients and wave motion; Jets; Naval hydrodynamics; Sprays; Stability and transition; Turbulence wakes microfluidics and other fundamental/applied fluid mechanical phenomena and processes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信