分析了将生产结果数据可视化应用于安顿线生产系统的Modbus TCP/IP的应用

Bonanza Yoma Pratama, Efi Anisa
{"title":"分析了将生产结果数据可视化应用于安顿线生产系统的Modbus TCP/IP的应用","authors":"Bonanza Yoma Pratama, Efi Anisa","doi":"10.35814/asiimetrik.v5i1.3791","DOIUrl":null,"url":null,"abstract":"Andon refers to an information system aimed at management, maintenance, planners, or other workers regarding quality, process, or quantity issues. To support accurate data communication, a reliable protocol and high precision are required. The Modbus TCP/IP protocol is compatible with Andon systems. This study aims to analyze the implementation of Modbus TCP/IP communication in the application of production data visualization in online production systems. At a certain distance, the antenna's data must display the data's precision in real time. The average data transfer time at the farthest distance tested, 50 meters, was 0.0043 seconds, indicating that the longer the distance between the client and server, the longer the waiting time tends to be, but does not exceed 0.01 seconds if it does not affect production activities. These results are still pertinent to the information required by the organization.","PeriodicalId":490621,"journal":{"name":"Jurnal Asiimetrik","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analisis Implementasi Komunikasi Modbus TCP/IP dalam Penerapan Visualisasi Data Hasil Produksi pada Sistem Andon Line Production\",\"authors\":\"Bonanza Yoma Pratama, Efi Anisa\",\"doi\":\"10.35814/asiimetrik.v5i1.3791\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Andon refers to an information system aimed at management, maintenance, planners, or other workers regarding quality, process, or quantity issues. To support accurate data communication, a reliable protocol and high precision are required. The Modbus TCP/IP protocol is compatible with Andon systems. This study aims to analyze the implementation of Modbus TCP/IP communication in the application of production data visualization in online production systems. At a certain distance, the antenna's data must display the data's precision in real time. The average data transfer time at the farthest distance tested, 50 meters, was 0.0043 seconds, indicating that the longer the distance between the client and server, the longer the waiting time tends to be, but does not exceed 0.01 seconds if it does not affect production activities. These results are still pertinent to the information required by the organization.\",\"PeriodicalId\":490621,\"journal\":{\"name\":\"Jurnal Asiimetrik\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Asiimetrik\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35814/asiimetrik.v5i1.3791\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Asiimetrik","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35814/asiimetrik.v5i1.3791","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

Andon指的是针对管理人员、维护人员、计划人员或其他有关质量、过程或数量问题的工作人员的信息系统。为了支持准确的数据通信,需要可靠的协议和较高的精度。Modbus TCP/IP协议兼容Andon系统。本研究旨在分析Modbus TCP/IP通信在生产数据可视化在在线生产系统中的应用。在一定距离上,天线的数据必须实时显示数据的精度。在测试的最远距离50米时,平均数据传输时间为0.0043秒,这表明客户机和服务器之间的距离越长,等待时间越长,但如果不影响生产活动,则不会超过0.01秒。这些结果仍然与组织所需的信息相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analisis Implementasi Komunikasi Modbus TCP/IP dalam Penerapan Visualisasi Data Hasil Produksi pada Sistem Andon Line Production
Andon refers to an information system aimed at management, maintenance, planners, or other workers regarding quality, process, or quantity issues. To support accurate data communication, a reliable protocol and high precision are required. The Modbus TCP/IP protocol is compatible with Andon systems. This study aims to analyze the implementation of Modbus TCP/IP communication in the application of production data visualization in online production systems. At a certain distance, the antenna's data must display the data's precision in real time. The average data transfer time at the farthest distance tested, 50 meters, was 0.0043 seconds, indicating that the longer the distance between the client and server, the longer the waiting time tends to be, but does not exceed 0.01 seconds if it does not affect production activities. These results are still pertinent to the information required by the organization.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信