980nm二极管激光缩小敏感牙暴露牙本质小管直径的效果

Rana Hashim, Mohammed Dhahir, Salah A. AlKurtas
{"title":"980nm二极管激光缩小敏感牙暴露牙本质小管直径的效果","authors":"Rana Hashim, Mohammed Dhahir, Salah A. AlKurtas","doi":"10.31900/ijl.v22i1.373","DOIUrl":null,"url":null,"abstract":"Abstracts: Background: The oral cavity is a complex environment, both structurally and functionally, the hard and soft tissues are in close a proximity. Oral tissues subjected to wear throughout the life, that threatened the vitality of the pulp or increase the sensitivity of dentinal tubules. One of the common dental problems is loss of enamel or cementum, which stimulate the nerve ending in or near the pulp and manifested as pain sensation. Aim of the study: This study had done to evaluate the effects of 980nm diode Laser in diameters reduction of exposed dentinal tubules analyze the results and morphological changes of irradiated dentine surface by FE-SEM (field emission scanning electron microscope) analysis. Material and Method: Thirty-nine human extracted impacted 3rd molar teeth were tested in this study and divided into control Group (N=15), pilot study (N=9) and study group (N=15). The study group irradiated with 980nm diode Laser to the occlusal surface of the teeth after the application of 17% EDTA (Ethelyn diamine tetra acetic acid) for smear layer removal. The intra-pulpal temperature recorded for every second and monitored for 120s from the first second of irradiation by a thermometer (prośket MT-1820, 1st Edition, 2016, Taiwan), for detection the recovery time of initial tooth temperature. FE-SEM analysis to all teeth (control, pilot and study groups) for assessment the morphological changes after surface irradiation. Results: FE-SEM analysis to the irradiated surface show significant reduction in diameters of the exposed dentinal tubules irradiated by 980nm diode Laser. Conclusion: The selected parameters (1.5W/10s, 276.3W/cm2) were able to seal exposed dentinal tubules without any sign of cracks or fissures. Suggestion: The parameters used with this study (1.5W, 10s, 276.3W/cm2) can be utilize in the future treatment protocol to the management of dentinal hypersensitivity.","PeriodicalId":500031,"journal":{"name":"Iraqi journal of laser","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effectiveness of 980nm diode Laser in reduction the diameters of exposed dentinal tubules for hypersensitive tooth\",\"authors\":\"Rana Hashim, Mohammed Dhahir, Salah A. AlKurtas\",\"doi\":\"10.31900/ijl.v22i1.373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstracts: Background: The oral cavity is a complex environment, both structurally and functionally, the hard and soft tissues are in close a proximity. Oral tissues subjected to wear throughout the life, that threatened the vitality of the pulp or increase the sensitivity of dentinal tubules. One of the common dental problems is loss of enamel or cementum, which stimulate the nerve ending in or near the pulp and manifested as pain sensation. Aim of the study: This study had done to evaluate the effects of 980nm diode Laser in diameters reduction of exposed dentinal tubules analyze the results and morphological changes of irradiated dentine surface by FE-SEM (field emission scanning electron microscope) analysis. Material and Method: Thirty-nine human extracted impacted 3rd molar teeth were tested in this study and divided into control Group (N=15), pilot study (N=9) and study group (N=15). The study group irradiated with 980nm diode Laser to the occlusal surface of the teeth after the application of 17% EDTA (Ethelyn diamine tetra acetic acid) for smear layer removal. The intra-pulpal temperature recorded for every second and monitored for 120s from the first second of irradiation by a thermometer (prośket MT-1820, 1st Edition, 2016, Taiwan), for detection the recovery time of initial tooth temperature. FE-SEM analysis to all teeth (control, pilot and study groups) for assessment the morphological changes after surface irradiation. Results: FE-SEM analysis to the irradiated surface show significant reduction in diameters of the exposed dentinal tubules irradiated by 980nm diode Laser. Conclusion: The selected parameters (1.5W/10s, 276.3W/cm2) were able to seal exposed dentinal tubules without any sign of cracks or fissures. Suggestion: The parameters used with this study (1.5W, 10s, 276.3W/cm2) can be utilize in the future treatment protocol to the management of dentinal hypersensitivity.\",\"PeriodicalId\":500031,\"journal\":{\"name\":\"Iraqi journal of laser\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iraqi journal of laser\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31900/ijl.v22i1.373\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iraqi journal of laser","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31900/ijl.v22i1.373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要/ abstract摘要:背景:口腔是一个复杂的环境,无论是结构上还是功能上,硬组织和软组织都是紧密相连的。口腔组织终生受到磨损,即威胁牙髓的活力或增加牙本质小管的敏感性。牙釉质或牙骨质的丧失是常见的牙齿问题之一,牙釉质或牙骨质的丧失会刺激牙髓或牙髓附近的神经末梢,表现为痛感。研究目的:评价980nm二极管激光对暴露牙本质小管的减径效果,用场发射扫描电镜(FE-SEM)分析辐照后牙本质表面的形貌变化。材料与方法:本研究对39颗拔除的人阻生第三磨牙进行试验,分为对照组(N=15)、中试组(N=9)和研究组(N=15)。研究组应用17%乙二胺四乙酸(EDTA)去除涂膜后,用980nm二极管激光照射牙齿咬合面。用体温计(prośket MT-1820,第一版,2016,台湾)每秒钟记录一次牙髓内温度,从照射第一秒开始监测120秒,检测初始牙温恢复时间。对所有牙齿(对照组、中试组和研究组)进行FE-SEM分析,评估表面辐照后的形态学变化。结果:对照射表面的FE-SEM分析表明,980nm二极管激光照射后,暴露的牙本质小管直径明显减小。结论:所选参数(1.5W/10s, 276.3W/cm2)能够封闭外露的牙本质小管,且无裂缝迹象。建议:本研究采用的参数(1.5W、10s、276.3W/cm2)可作为今后治疗牙本质过敏的参考参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effectiveness of 980nm diode Laser in reduction the diameters of exposed dentinal tubules for hypersensitive tooth
Abstracts: Background: The oral cavity is a complex environment, both structurally and functionally, the hard and soft tissues are in close a proximity. Oral tissues subjected to wear throughout the life, that threatened the vitality of the pulp or increase the sensitivity of dentinal tubules. One of the common dental problems is loss of enamel or cementum, which stimulate the nerve ending in or near the pulp and manifested as pain sensation. Aim of the study: This study had done to evaluate the effects of 980nm diode Laser in diameters reduction of exposed dentinal tubules analyze the results and morphological changes of irradiated dentine surface by FE-SEM (field emission scanning electron microscope) analysis. Material and Method: Thirty-nine human extracted impacted 3rd molar teeth were tested in this study and divided into control Group (N=15), pilot study (N=9) and study group (N=15). The study group irradiated with 980nm diode Laser to the occlusal surface of the teeth after the application of 17% EDTA (Ethelyn diamine tetra acetic acid) for smear layer removal. The intra-pulpal temperature recorded for every second and monitored for 120s from the first second of irradiation by a thermometer (prośket MT-1820, 1st Edition, 2016, Taiwan), for detection the recovery time of initial tooth temperature. FE-SEM analysis to all teeth (control, pilot and study groups) for assessment the morphological changes after surface irradiation. Results: FE-SEM analysis to the irradiated surface show significant reduction in diameters of the exposed dentinal tubules irradiated by 980nm diode Laser. Conclusion: The selected parameters (1.5W/10s, 276.3W/cm2) were able to seal exposed dentinal tubules without any sign of cracks or fissures. Suggestion: The parameters used with this study (1.5W, 10s, 276.3W/cm2) can be utilize in the future treatment protocol to the management of dentinal hypersensitivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信