T2多重回波数据成像与快速自旋回波脂肪饱和技术相结合,提高踝部磁共振成像成像质量

IF 0.4 Q3 MEDICINE, GENERAL & INTERNAL
Akhmad Muzamil, Chendra Wandani, Dita Hariyani, Riries Rulaningtyas, Khusnul Ain, Perwira Permatasari, Suryani Astuti
{"title":"T2多重回波数据成像与快速自旋回波脂肪饱和技术相结合,提高踝部磁共振成像成像质量","authors":"Akhmad Muzamil, Chendra Wandani, Dita Hariyani, Riries Rulaningtyas, Khusnul Ain, Perwira Permatasari, Suryani Astuti","doi":"10.5455/rmj.20220320122308","DOIUrl":null,"url":null,"abstract":"Objective: To determine the effect of the T2 Fast Spin Echo Fat Saturation (T2 FSE FAT SAT) sequence and T2 Multiple Echo Data Imaging Combination (T2 MEDIC) sequence on ankle images MRI. Methodology: The sequence variations were T2 FSE FAT SAT and T2 MEDIC. The effect of the sequence on the quality of the MRI ankle image was analyzed on the image of one patient and the sound intensity value through a sound level meter. Result: Data analysis was carried out quantitatively with the Region of Interest (ROI) method directly on the computer image of the MRI, then SNR (Signal to Noise Ratio) and CNR (Contras to Noise Ratio) analysis were carried out, and PSNR and MSE analysis was carried out through digital image processing to determine the value magnitudes. The highest SNR and CNR were found in the T2 MEDIC sequence. The lowest acoustic noise value is in the T2 MEDIC sequence. The differences in the physical mechanism of image formation are T2 FSE FAT SAT refocusing 180º RF and T2 MEDIC refocusing gradient fields. Conclusion: Because the SNR and CNR on T2 MEDIC are higher and the value of the sound intensity level is low, it can be said that the sequence provides optimal results and low acoustic noise.","PeriodicalId":20844,"journal":{"name":"Rawal Medical Journal","volume":"18 1","pages":"0"},"PeriodicalIF":0.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Combination T2 multiple echo data imaging and fast spin echo fat saturation technique to improve image quality on ankle magnetic resonance imaging\",\"authors\":\"Akhmad Muzamil, Chendra Wandani, Dita Hariyani, Riries Rulaningtyas, Khusnul Ain, Perwira Permatasari, Suryani Astuti\",\"doi\":\"10.5455/rmj.20220320122308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To determine the effect of the T2 Fast Spin Echo Fat Saturation (T2 FSE FAT SAT) sequence and T2 Multiple Echo Data Imaging Combination (T2 MEDIC) sequence on ankle images MRI. Methodology: The sequence variations were T2 FSE FAT SAT and T2 MEDIC. The effect of the sequence on the quality of the MRI ankle image was analyzed on the image of one patient and the sound intensity value through a sound level meter. Result: Data analysis was carried out quantitatively with the Region of Interest (ROI) method directly on the computer image of the MRI, then SNR (Signal to Noise Ratio) and CNR (Contras to Noise Ratio) analysis were carried out, and PSNR and MSE analysis was carried out through digital image processing to determine the value magnitudes. The highest SNR and CNR were found in the T2 MEDIC sequence. The lowest acoustic noise value is in the T2 MEDIC sequence. The differences in the physical mechanism of image formation are T2 FSE FAT SAT refocusing 180º RF and T2 MEDIC refocusing gradient fields. Conclusion: Because the SNR and CNR on T2 MEDIC are higher and the value of the sound intensity level is low, it can be said that the sequence provides optimal results and low acoustic noise.\",\"PeriodicalId\":20844,\"journal\":{\"name\":\"Rawal Medical Journal\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rawal Medical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5455/rmj.20220320122308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rawal Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/rmj.20220320122308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨T2快速自旋回波脂肪饱和度序列(T2 FSE Fat SAT)和T2多重回波数据成像组合序列(T2 MEDIC)对踝关节MRI图像的影响。方法:序列变异为T2 FSE FAT SAT和T2 MEDIC。分析了序列对MRI踝关节图像质量的影响,并通过声级计测量声强值。结果:直接对MRI计算机图像采用感兴趣区域(Region of Interest, ROI)法进行定量数据分析,然后进行信噪比(SNR)和反噪比(CNR)分析,通过数字图像处理进行PSNR和MSE分析,确定值的幅度。T2 MEDIC序列的信噪比和CNR最高。T2 MEDIC序列的噪声值最低。成像物理机制的差异在于T2 FSE FAT SAT重新聚焦180ºRF和T2 MEDIC重新聚焦梯度场。结论:由于T2 MEDIC上的信噪比和北噪比较高,声强级值较低,因此可以说该序列效果最佳,噪声较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combination T2 multiple echo data imaging and fast spin echo fat saturation technique to improve image quality on ankle magnetic resonance imaging
Objective: To determine the effect of the T2 Fast Spin Echo Fat Saturation (T2 FSE FAT SAT) sequence and T2 Multiple Echo Data Imaging Combination (T2 MEDIC) sequence on ankle images MRI. Methodology: The sequence variations were T2 FSE FAT SAT and T2 MEDIC. The effect of the sequence on the quality of the MRI ankle image was analyzed on the image of one patient and the sound intensity value through a sound level meter. Result: Data analysis was carried out quantitatively with the Region of Interest (ROI) method directly on the computer image of the MRI, then SNR (Signal to Noise Ratio) and CNR (Contras to Noise Ratio) analysis were carried out, and PSNR and MSE analysis was carried out through digital image processing to determine the value magnitudes. The highest SNR and CNR were found in the T2 MEDIC sequence. The lowest acoustic noise value is in the T2 MEDIC sequence. The differences in the physical mechanism of image formation are T2 FSE FAT SAT refocusing 180º RF and T2 MEDIC refocusing gradient fields. Conclusion: Because the SNR and CNR on T2 MEDIC are higher and the value of the sound intensity level is low, it can be said that the sequence provides optimal results and low acoustic noise.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Rawal Medical Journal
Rawal Medical Journal MEDICINE, GENERAL & INTERNAL-
CiteScore
0.70
自引率
0.00%
发文量
6
期刊介绍: RMJ is a general Medicine publication and accepts oorigial articles, editorials, case reports and commentaries. It aims to dessiminate medical knowldge to professional community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信