{"title":"利用体外释放试验(IVRT)评估1%克霉唑乳膏作为生物缓释剂的“一致性”","authors":"Hannah Wellington, Seeprarani Rath, Sagaran Abboo, Isadore Kanfer","doi":"10.1186/s41120-023-00087-4","DOIUrl":null,"url":null,"abstract":"Abstract The October 2022 draft United States Food and Drug Administration (FDA) guidance presents an option of in vitro release test (IVRT) studies as a biowaiver for topical drug products submitted in abbreviated new drug applications (ANDAs). However, the product-specific guidance (PSG) for 1% clotrimazole (CLZ) topical cream does not provide an in vitro option for biowaiver and requires a clinical endpoint study to demonstrate bioequivalence (BE). Therefore, the main objective was to use IVRT to investigate pharmaceutical equivalence of several 1% CLZ topical creams from two countries — South Africa (SA) and Canada. This investigation aims at demonstrating the utility of IVRT to determine ‘sameness’ and/or differences between topical creams containing 1% CLZ and the potential of IVRT for supporting biowaivers, thereby obviating the necessity to conduct clinical endpoint studies in patients. A validated IVRT method was applied to conduct comparative IVRT runs on five generic products marketed in SA and one Canadian generic, which were compared against a relevant comparator product from their country of origin in accordance with the FDA’s acceptance criteria of 75–133.33%. All five SA-marketed generic creams showed pharmaceutical inequivalence to the SA comparator product indicating Q1/Q2/Q3 differences. Despite containing the same excipients as both comparator products, the Canadian generic showed substantially lower release rate compared to the comparator products which could be attributed to Q2/Q3 differences. The IVRT method displayed the requisite ability to assess the various 1% CLZ creams and confirmed the potential of the IVRT method to support a biowaiver for 1% CLZ topical creams. Graphical Abstract","PeriodicalId":453,"journal":{"name":"AAPS Open","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Utility of in vitro release testing (IVRT) to assess ‘sameness’ of 1% clotrimazole creams for use as a biowaiver\",\"authors\":\"Hannah Wellington, Seeprarani Rath, Sagaran Abboo, Isadore Kanfer\",\"doi\":\"10.1186/s41120-023-00087-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The October 2022 draft United States Food and Drug Administration (FDA) guidance presents an option of in vitro release test (IVRT) studies as a biowaiver for topical drug products submitted in abbreviated new drug applications (ANDAs). However, the product-specific guidance (PSG) for 1% clotrimazole (CLZ) topical cream does not provide an in vitro option for biowaiver and requires a clinical endpoint study to demonstrate bioequivalence (BE). Therefore, the main objective was to use IVRT to investigate pharmaceutical equivalence of several 1% CLZ topical creams from two countries — South Africa (SA) and Canada. This investigation aims at demonstrating the utility of IVRT to determine ‘sameness’ and/or differences between topical creams containing 1% CLZ and the potential of IVRT for supporting biowaivers, thereby obviating the necessity to conduct clinical endpoint studies in patients. A validated IVRT method was applied to conduct comparative IVRT runs on five generic products marketed in SA and one Canadian generic, which were compared against a relevant comparator product from their country of origin in accordance with the FDA’s acceptance criteria of 75–133.33%. All five SA-marketed generic creams showed pharmaceutical inequivalence to the SA comparator product indicating Q1/Q2/Q3 differences. Despite containing the same excipients as both comparator products, the Canadian generic showed substantially lower release rate compared to the comparator products which could be attributed to Q2/Q3 differences. The IVRT method displayed the requisite ability to assess the various 1% CLZ creams and confirmed the potential of the IVRT method to support a biowaiver for 1% CLZ topical creams. Graphical Abstract\",\"PeriodicalId\":453,\"journal\":{\"name\":\"AAPS Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AAPS Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s41120-023-00087-4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AAPS Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s41120-023-00087-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Utility of in vitro release testing (IVRT) to assess ‘sameness’ of 1% clotrimazole creams for use as a biowaiver
Abstract The October 2022 draft United States Food and Drug Administration (FDA) guidance presents an option of in vitro release test (IVRT) studies as a biowaiver for topical drug products submitted in abbreviated new drug applications (ANDAs). However, the product-specific guidance (PSG) for 1% clotrimazole (CLZ) topical cream does not provide an in vitro option for biowaiver and requires a clinical endpoint study to demonstrate bioequivalence (BE). Therefore, the main objective was to use IVRT to investigate pharmaceutical equivalence of several 1% CLZ topical creams from two countries — South Africa (SA) and Canada. This investigation aims at demonstrating the utility of IVRT to determine ‘sameness’ and/or differences between topical creams containing 1% CLZ and the potential of IVRT for supporting biowaivers, thereby obviating the necessity to conduct clinical endpoint studies in patients. A validated IVRT method was applied to conduct comparative IVRT runs on five generic products marketed in SA and one Canadian generic, which were compared against a relevant comparator product from their country of origin in accordance with the FDA’s acceptance criteria of 75–133.33%. All five SA-marketed generic creams showed pharmaceutical inequivalence to the SA comparator product indicating Q1/Q2/Q3 differences. Despite containing the same excipients as both comparator products, the Canadian generic showed substantially lower release rate compared to the comparator products which could be attributed to Q2/Q3 differences. The IVRT method displayed the requisite ability to assess the various 1% CLZ creams and confirmed the potential of the IVRT method to support a biowaiver for 1% CLZ topical creams. Graphical Abstract