Aline Lima Pestana Magalhães, Betina Savi Goetze, Neide da Silva Knihs, Daiana de Mattia, Elza Lima da Silva
{"title":"肝移植血液治疗注意仪的内容验证:促进健康生物监测","authors":"Aline Lima Pestana Magalhães, Betina Savi Goetze, Neide da Silva Knihs, Daiana de Mattia, Elza Lima da Silva","doi":"10.15253/2175-6783.20232489226","DOIUrl":null,"url":null,"abstract":"Objective: to develop and validate the content of an instrument to monitor hemotherapy attention in liver transplant patients. Methods: methodological study in two stages: 1) Scoping review to identify relevant topics for the elaboration of the instrument; 2) Content validation with five specialists in two rounds, using the Delphi technique. Results: the final version of the instrument for hemotherapy care to liver transplant patients had four dimensions: Patient identification; Preoperative; Intraoperative; and Postoperative, to a total of 54 items. After the second round, all items had a content validation index of 0.8 or higher, and the instrument had a final score of 0.97. Conclusion: the instrument showed evidence of content validity, meaning it is a useful tool to monitor hemotherapy care for liver transplant patients. Contributions for the practice: the validation of this instrument will provide teams of transfusion and transplant centers with essential information to guide safe and efficient hemotherapy attention during the entirety of the liver transplant process.","PeriodicalId":243005,"journal":{"name":"Northeast Network Nursing Journal","volume":"155 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Content validation of an instrument for hemotherapy attention in liver transplants: promoting biomonitoring in health\",\"authors\":\"Aline Lima Pestana Magalhães, Betina Savi Goetze, Neide da Silva Knihs, Daiana de Mattia, Elza Lima da Silva\",\"doi\":\"10.15253/2175-6783.20232489226\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: to develop and validate the content of an instrument to monitor hemotherapy attention in liver transplant patients. Methods: methodological study in two stages: 1) Scoping review to identify relevant topics for the elaboration of the instrument; 2) Content validation with five specialists in two rounds, using the Delphi technique. Results: the final version of the instrument for hemotherapy care to liver transplant patients had four dimensions: Patient identification; Preoperative; Intraoperative; and Postoperative, to a total of 54 items. After the second round, all items had a content validation index of 0.8 or higher, and the instrument had a final score of 0.97. Conclusion: the instrument showed evidence of content validity, meaning it is a useful tool to monitor hemotherapy care for liver transplant patients. Contributions for the practice: the validation of this instrument will provide teams of transfusion and transplant centers with essential information to guide safe and efficient hemotherapy attention during the entirety of the liver transplant process.\",\"PeriodicalId\":243005,\"journal\":{\"name\":\"Northeast Network Nursing Journal\",\"volume\":\"155 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Northeast Network Nursing Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15253/2175-6783.20232489226\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Northeast Network Nursing Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15253/2175-6783.20232489226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Content validation of an instrument for hemotherapy attention in liver transplants: promoting biomonitoring in health
Objective: to develop and validate the content of an instrument to monitor hemotherapy attention in liver transplant patients. Methods: methodological study in two stages: 1) Scoping review to identify relevant topics for the elaboration of the instrument; 2) Content validation with five specialists in two rounds, using the Delphi technique. Results: the final version of the instrument for hemotherapy care to liver transplant patients had four dimensions: Patient identification; Preoperative; Intraoperative; and Postoperative, to a total of 54 items. After the second round, all items had a content validation index of 0.8 or higher, and the instrument had a final score of 0.97. Conclusion: the instrument showed evidence of content validity, meaning it is a useful tool to monitor hemotherapy care for liver transplant patients. Contributions for the practice: the validation of this instrument will provide teams of transfusion and transplant centers with essential information to guide safe and efficient hemotherapy attention during the entirety of the liver transplant process.