经导管主动脉瓣置换术治疗单纯原生主动脉反流患者:来自多中心注册研究的结果

Xiaofei Gao, Juan Zhang, Xiangquan Kong, Jing Chen, Xiang Chen, Longyan Zhang, Xinyong Cai, Jiancheng Zhu, Nailiang Tian, Zhen Ge, Bin Wang, Qing Zhou, Xi Su, Lang Hong, Yan Wang, Hong Jiang, Junjie Zhang, Shaoliang Chen
{"title":"经导管主动脉瓣置换术治疗单纯原生主动脉反流患者:来自多中心注册研究的结果","authors":"Xiaofei Gao, Juan Zhang, Xiangquan Kong, Jing Chen, Xiang Chen, Longyan Zhang, Xinyong Cai, Jiancheng Zhu, Nailiang Tian, Zhen Ge, Bin Wang, Qing Zhou, Xi Su, Lang Hong, Yan Wang, Hong Jiang, Junjie Zhang, Shaoliang Chen","doi":"10.1097/cd9.0000000000000101","DOIUrl":null,"url":null,"abstract":"Objective: Patients with untreated severe aortic regurgitation (AR) have a high risk of mortality. Transfemoral transcatheter aortic valve replacement (TF-TAVR) is a treatment option for AR; however, the safety and efficacy of this technique have not been sufficiently established. This study aimed to evaluate the clinical and anatomical variables correlating with device success of TF-TAVR using a self-expanding valve system for pure AR. Methods: Patients with pure native severe AR who underwent TF-TAVR using a self-expanding valve system were registered at 5 Chinese centers. The primary endpoint was device success at 1 month after TAVR. The secondary endpoint was the composite of major adverse cardiovascular events (MACE) at 6 months, including all-cause death, ischemic stroke, emergency conversion to cardiac surgery, and permanent pacemaker implantation. Echocardiography was used to analyze the left ventricular function before the TAVR procedure and during follow-up. Multivariable logistic regression and Cox regression analyses were performed to find relevant independent risk factors. Results: Between September 2019 and February 2022, 79 patients with AR were enrolled in the study. At 1 month, device success was achieved in 60 (75.9%) patients. By 6 months, 29 (36.7%) patients had MACE. Echocardiography revealed improved left ventricular function after TAVR. Multivariate regression analysis demonstrated that the Society of Thoracic Surgeons (STS) risk score (odds ratio (OR) 0.760, 95% confidence interval (CI): 0.584–0.989; P = 0.041) and annulus perimeter (OR 0.888, 95% CI: 0.796–0.992; P = 0.035) were 2 predictors of device success. Moreover, annulus perimeter (<80.2 mm), but not STS risk score, was associated with a significant reduction in MACE at 6 months (hazard ratio (HR) 2.223, 95% CI: 1.060–4.659; P = 0.028). Conclusions: TF-TAVR using a self-expanding valve system appears to be a safe and feasible treatment for patients with pure native severe AR, particularly those with a less enlarged annulus.","PeriodicalId":72524,"journal":{"name":"Cardiology discovery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transcatheter Aortic Valve Replacement in Patients with Pure Native Aortic Regurgitation: Results from a Multicenter Registry Study\",\"authors\":\"Xiaofei Gao, Juan Zhang, Xiangquan Kong, Jing Chen, Xiang Chen, Longyan Zhang, Xinyong Cai, Jiancheng Zhu, Nailiang Tian, Zhen Ge, Bin Wang, Qing Zhou, Xi Su, Lang Hong, Yan Wang, Hong Jiang, Junjie Zhang, Shaoliang Chen\",\"doi\":\"10.1097/cd9.0000000000000101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: Patients with untreated severe aortic regurgitation (AR) have a high risk of mortality. Transfemoral transcatheter aortic valve replacement (TF-TAVR) is a treatment option for AR; however, the safety and efficacy of this technique have not been sufficiently established. This study aimed to evaluate the clinical and anatomical variables correlating with device success of TF-TAVR using a self-expanding valve system for pure AR. Methods: Patients with pure native severe AR who underwent TF-TAVR using a self-expanding valve system were registered at 5 Chinese centers. The primary endpoint was device success at 1 month after TAVR. The secondary endpoint was the composite of major adverse cardiovascular events (MACE) at 6 months, including all-cause death, ischemic stroke, emergency conversion to cardiac surgery, and permanent pacemaker implantation. Echocardiography was used to analyze the left ventricular function before the TAVR procedure and during follow-up. Multivariable logistic regression and Cox regression analyses were performed to find relevant independent risk factors. Results: Between September 2019 and February 2022, 79 patients with AR were enrolled in the study. At 1 month, device success was achieved in 60 (75.9%) patients. By 6 months, 29 (36.7%) patients had MACE. Echocardiography revealed improved left ventricular function after TAVR. Multivariate regression analysis demonstrated that the Society of Thoracic Surgeons (STS) risk score (odds ratio (OR) 0.760, 95% confidence interval (CI): 0.584–0.989; P = 0.041) and annulus perimeter (OR 0.888, 95% CI: 0.796–0.992; P = 0.035) were 2 predictors of device success. Moreover, annulus perimeter (<80.2 mm), but not STS risk score, was associated with a significant reduction in MACE at 6 months (hazard ratio (HR) 2.223, 95% CI: 1.060–4.659; P = 0.028). Conclusions: TF-TAVR using a self-expanding valve system appears to be a safe and feasible treatment for patients with pure native severe AR, particularly those with a less enlarged annulus.\",\"PeriodicalId\":72524,\"journal\":{\"name\":\"Cardiology discovery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology discovery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/cd9.0000000000000101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology discovery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/cd9.0000000000000101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:严重主动脉瓣反流(AR)患者未经治疗死亡率高。经股经导管主动脉瓣置换术(TF-TAVR)是治疗AR的一种选择;然而,这项技术的安全性和有效性还没有得到充分的证实。本研究旨在评估使用自扩张瓣膜系统进行纯AR的TF-TAVR装置成功的临床和解剖学变量。方法:在中国5个中心登记了使用自扩张瓣膜系统进行TF-TAVR的纯原生严重AR患者。主要终点是TAVR后1个月装置成功。次要终点是6个月时主要心血管不良事件(MACE)的综合,包括全因死亡、缺血性卒中、紧急转行心脏手术和永久性起搏器植入。超声心动图分析TAVR术前和随访期间的左心室功能。采用多变量logistic回归和Cox回归分析,寻找相关的独立危险因素。结果:2019年9月至2022年2月期间,79名AR患者入组研究。1个月时,60例(75.9%)患者装置成功。6个月时,29例(36.7%)患者出现MACE。超声心动图显示TAVR术后左心室功能改善。多因素回归分析显示,胸外科学会(STS)风险评分(优势比(OR) 0.760, 95%可信区间(CI): 0.584-0.989;P = 0.041)和环周(OR 0.888, 95% CI: 0.796-0.992;P = 0.035)是器械成功的2个预测因子。此外,环周(80.2 mm),而不是STS风险评分,与6个月时MACE的显著降低相关(风险比(HR) 2.223, 95% CI: 1.060-4.659;P = 0.028)。结论:使用自扩张瓣膜系统的TF-TAVR似乎是一种安全可行的治疗方法,用于单纯的原生严重AR患者,特别是那些环扩大较小的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transcatheter Aortic Valve Replacement in Patients with Pure Native Aortic Regurgitation: Results from a Multicenter Registry Study
Objective: Patients with untreated severe aortic regurgitation (AR) have a high risk of mortality. Transfemoral transcatheter aortic valve replacement (TF-TAVR) is a treatment option for AR; however, the safety and efficacy of this technique have not been sufficiently established. This study aimed to evaluate the clinical and anatomical variables correlating with device success of TF-TAVR using a self-expanding valve system for pure AR. Methods: Patients with pure native severe AR who underwent TF-TAVR using a self-expanding valve system were registered at 5 Chinese centers. The primary endpoint was device success at 1 month after TAVR. The secondary endpoint was the composite of major adverse cardiovascular events (MACE) at 6 months, including all-cause death, ischemic stroke, emergency conversion to cardiac surgery, and permanent pacemaker implantation. Echocardiography was used to analyze the left ventricular function before the TAVR procedure and during follow-up. Multivariable logistic regression and Cox regression analyses were performed to find relevant independent risk factors. Results: Between September 2019 and February 2022, 79 patients with AR were enrolled in the study. At 1 month, device success was achieved in 60 (75.9%) patients. By 6 months, 29 (36.7%) patients had MACE. Echocardiography revealed improved left ventricular function after TAVR. Multivariate regression analysis demonstrated that the Society of Thoracic Surgeons (STS) risk score (odds ratio (OR) 0.760, 95% confidence interval (CI): 0.584–0.989; P = 0.041) and annulus perimeter (OR 0.888, 95% CI: 0.796–0.992; P = 0.035) were 2 predictors of device success. Moreover, annulus perimeter (<80.2 mm), but not STS risk score, was associated with a significant reduction in MACE at 6 months (hazard ratio (HR) 2.223, 95% CI: 1.060–4.659; P = 0.028). Conclusions: TF-TAVR using a self-expanding valve system appears to be a safe and feasible treatment for patients with pure native severe AR, particularly those with a less enlarged annulus.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信