一种用于局部放电测量的高频电流互感器的设计与实现

Pub Date : 2023-01-01 DOI:10.1587/elex.20.20230450
Xuewen Yan, Chen Cheng, Juan Hu, Yuanyuan Bai, Wenwen Zhang
{"title":"一种用于局部放电测量的高频电流互感器的设计与实现","authors":"Xuewen Yan, Chen Cheng, Juan Hu, Yuanyuan Bai, Wenwen Zhang","doi":"10.1587/elex.20.20230450","DOIUrl":null,"url":null,"abstract":"This study focuses on the improvement of the performance of high-frequency current transformer (HFCT) for Partial Discharge Measurement and thus reveals a new design method of HFCT. An annular nickel-zinc ferrite is used as the magnetic core of the HFCT, and the parameters such as the number of winding turns and the diameter of the enameled wire are optimized. To test the HFCT, an experimental test platform is built according to the technical specifications of high-frequency partial discharge charged detection equipment. The test contents of the HFCT include transmission impedance, sensitivity, anti-interference characteristics, etc. The test results show that the new HFCT has a good response performance from 1MHz to 25MHz, the maximum transmission impedance value can reach 16.4mV/mA, the apparent charge of 5pC can be measured and signal-to-noise ratio is greater than 2:1. In addition, the designed HFCT also has good anti-interference and stability. With the self-designed low-power portable high-voltage cable insulation tester (mainly including signal conditioning circuit and data acquisition circuit), in the high-voltage laboratory, built a simulated discharge experimental circuit on the plate-pin, ball-ball two discharge models for high-voltage testing, the use of the developed HFCT to detect the partial discharge of the insulating polyethylene medium. The test results show that the HFCT can detect the partial discharge pulse signals before breakdown, with accurate data and reliable performance.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Implementation of A novel High-frequency Current Transformer for Partial Discharge Measurements\",\"authors\":\"Xuewen Yan, Chen Cheng, Juan Hu, Yuanyuan Bai, Wenwen Zhang\",\"doi\":\"10.1587/elex.20.20230450\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study focuses on the improvement of the performance of high-frequency current transformer (HFCT) for Partial Discharge Measurement and thus reveals a new design method of HFCT. An annular nickel-zinc ferrite is used as the magnetic core of the HFCT, and the parameters such as the number of winding turns and the diameter of the enameled wire are optimized. To test the HFCT, an experimental test platform is built according to the technical specifications of high-frequency partial discharge charged detection equipment. The test contents of the HFCT include transmission impedance, sensitivity, anti-interference characteristics, etc. The test results show that the new HFCT has a good response performance from 1MHz to 25MHz, the maximum transmission impedance value can reach 16.4mV/mA, the apparent charge of 5pC can be measured and signal-to-noise ratio is greater than 2:1. In addition, the designed HFCT also has good anti-interference and stability. With the self-designed low-power portable high-voltage cable insulation tester (mainly including signal conditioning circuit and data acquisition circuit), in the high-voltage laboratory, built a simulated discharge experimental circuit on the plate-pin, ball-ball two discharge models for high-voltage testing, the use of the developed HFCT to detect the partial discharge of the insulating polyethylene medium. The test results show that the HFCT can detect the partial discharge pulse signals before breakdown, with accurate data and reliable performance.\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1587/elex.20.20230450\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1587/elex.20.20230450","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究针对局部放电测量高频电流互感器(HFCT)的性能改进,提出了一种新的高频电流互感器设计方法。采用环形镍锌铁氧体作为HFCT的磁芯,并对绕组匝数和漆包线直径等参数进行了优化。根据高频局部放电充电检测设备技术规范,搭建实验测试平台,对高频局部放电充电检测设备进行测试。HFCT的测试内容包括传输阻抗、灵敏度、抗干扰特性等。测试结果表明,新型HFCT在1MHz ~ 25MHz范围内具有良好的响应性能,最大传输阻抗值可达16.4mV/mA,可测量5pC的视电荷,信噪比大于2:1。此外,所设计的HFCT还具有良好的抗干扰性和稳定性。利用自行设计的小功率便携式高压电缆绝缘测试仪(主要包括信号调理电路和数据采集电路),在高压实验室中,搭建了模拟放电实验电路,对板-引脚、球-球两种放电模式进行高压测试,利用研制的HFCT检测绝缘聚乙烯介质的局部放电。试验结果表明,HFCT能在击穿前检测到局部放电脉冲信号,数据准确,性能可靠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
Design and Implementation of A novel High-frequency Current Transformer for Partial Discharge Measurements
This study focuses on the improvement of the performance of high-frequency current transformer (HFCT) for Partial Discharge Measurement and thus reveals a new design method of HFCT. An annular nickel-zinc ferrite is used as the magnetic core of the HFCT, and the parameters such as the number of winding turns and the diameter of the enameled wire are optimized. To test the HFCT, an experimental test platform is built according to the technical specifications of high-frequency partial discharge charged detection equipment. The test contents of the HFCT include transmission impedance, sensitivity, anti-interference characteristics, etc. The test results show that the new HFCT has a good response performance from 1MHz to 25MHz, the maximum transmission impedance value can reach 16.4mV/mA, the apparent charge of 5pC can be measured and signal-to-noise ratio is greater than 2:1. In addition, the designed HFCT also has good anti-interference and stability. With the self-designed low-power portable high-voltage cable insulation tester (mainly including signal conditioning circuit and data acquisition circuit), in the high-voltage laboratory, built a simulated discharge experimental circuit on the plate-pin, ball-ball two discharge models for high-voltage testing, the use of the developed HFCT to detect the partial discharge of the insulating polyethylene medium. The test results show that the HFCT can detect the partial discharge pulse signals before breakdown, with accurate data and reliable performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信