高分辨液相色谱法在胆汁酸耐受性检测中的应用

Giornale di clinica medica Pub Date : 1990-01-01
F Marotta, L Hashimoto, P Safran
{"title":"高分辨液相色谱法在胆汁酸耐受性检测中的应用","authors":"F Marotta,&nbsp;L Hashimoto,&nbsp;P Safran","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In the present paper we have evaluated the accuracy of a fully automated liquid-chromatographic method to study the variations of serum bile acid concentration after oral administration of 500 mg of chenodeoxycholic as a bile acid tolerance test. The study population consisted of 11 subjects with liver cirrhosis (L.C.), 6 with chronic active hepatitis (C.A.H.) and of 15 healthy volunteers, as a control. A clear linear correlation was observed between the integrated peak area and the concentration of each bile acid. Bile acids were detected at a minimum concentration of 5 ng. Intra-assay variation, based on 10 consecutive determinations, was limited to a range of 0.42% and 3.23%. Compared to control group, L.C. and C.A.H. patients showed significantly higher levels of total bile acids and of CDCA. Significative was also the increase of glycine- and taurine-conjugates as well as the decrease of the ratio between the two. The present method, fully automated and using a low cost enzymatic reagent, has yielded an accurate analysis of bile acid fractions on a minute volume of serum in a short examination time.</p>","PeriodicalId":12732,"journal":{"name":"Giornale di clinica medica","volume":"71 1","pages":"31-6"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Application of high resolution liquid chromatography to the test of bile acid tolerance].\",\"authors\":\"F Marotta,&nbsp;L Hashimoto,&nbsp;P Safran\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In the present paper we have evaluated the accuracy of a fully automated liquid-chromatographic method to study the variations of serum bile acid concentration after oral administration of 500 mg of chenodeoxycholic as a bile acid tolerance test. The study population consisted of 11 subjects with liver cirrhosis (L.C.), 6 with chronic active hepatitis (C.A.H.) and of 15 healthy volunteers, as a control. A clear linear correlation was observed between the integrated peak area and the concentration of each bile acid. Bile acids were detected at a minimum concentration of 5 ng. Intra-assay variation, based on 10 consecutive determinations, was limited to a range of 0.42% and 3.23%. Compared to control group, L.C. and C.A.H. patients showed significantly higher levels of total bile acids and of CDCA. Significative was also the increase of glycine- and taurine-conjugates as well as the decrease of the ratio between the two. The present method, fully automated and using a low cost enzymatic reagent, has yielded an accurate analysis of bile acid fractions on a minute volume of serum in a short examination time.</p>\",\"PeriodicalId\":12732,\"journal\":{\"name\":\"Giornale di clinica medica\",\"volume\":\"71 1\",\"pages\":\"31-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Giornale di clinica medica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale di clinica medica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本文中,我们评估了全自动液相色谱法研究口服500毫克鹅去氧胆酸作为胆汁酸耐量试验后血清胆汁酸浓度变化的准确性。研究人群包括11名肝硬化(L.C.)患者,6名慢性活动性肝炎(C.A.H.)患者和15名健康志愿者作为对照。综合峰面积与各胆汁酸浓度呈明显的线性相关。最低浓度为5 ng时检测胆汁酸。基于连续10次测定,测定内变异限制在0.42%和3.23%的范围内。与对照组相比,L.C.和C.A.H.患者的总胆汁酸和CDCA水平明显升高。值得注意的是甘氨酸和牛磺酸缀合物的增加以及两者之间比率的降低。目前的方法是全自动的,使用低成本的酶试剂,在很短的检查时间内对一分钟体积的血清中的胆汁酸组分进行了准确的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Application of high resolution liquid chromatography to the test of bile acid tolerance].

In the present paper we have evaluated the accuracy of a fully automated liquid-chromatographic method to study the variations of serum bile acid concentration after oral administration of 500 mg of chenodeoxycholic as a bile acid tolerance test. The study population consisted of 11 subjects with liver cirrhosis (L.C.), 6 with chronic active hepatitis (C.A.H.) and of 15 healthy volunteers, as a control. A clear linear correlation was observed between the integrated peak area and the concentration of each bile acid. Bile acids were detected at a minimum concentration of 5 ng. Intra-assay variation, based on 10 consecutive determinations, was limited to a range of 0.42% and 3.23%. Compared to control group, L.C. and C.A.H. patients showed significantly higher levels of total bile acids and of CDCA. Significative was also the increase of glycine- and taurine-conjugates as well as the decrease of the ratio between the two. The present method, fully automated and using a low cost enzymatic reagent, has yielded an accurate analysis of bile acid fractions on a minute volume of serum in a short examination time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信