有效的边缘检测算子可以提高COVID-19胸部ct扫描的图像质量

None Prima Selvia Megawati, None M. Choiroel Anwar, None Fatimah, None Sudiyono, None Darmini, None Saifudin
{"title":"有效的边缘检测算子可以提高COVID-19胸部ct扫描的图像质量","authors":"None Prima Selvia Megawati, None M. Choiroel Anwar, None Fatimah, None Sudiyono, None Darmini, None Saifudin","doi":"10.20473/jvhs.v7.i2.2023.77-82","DOIUrl":null,"url":null,"abstract":"Background: Thorax CT scan is one of the medical supports that contributes most importantly to the diagnosis, especially cases of COVID-19. The disadvantage that has a CT scan image is noise. When the noise is high then the Signal Noise Ratio (SNR) value produced is low. Canny operator edge detection technique is one solution to animate noise. Purpose: Analyzing differences in image quality and anatomical information on thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection techniques. Method: A quasi experimental research on thorax CT Scan images before and after the application of canny operator edge detection which amounted to 10 samples. Image assessment is done by measuring noise, SNR, and anatomical information. Differences in image quality (noise and SNR) are tested with paired T-tests. Anatomical information is tested with the Wilcoxon Signed Rank Test. Result: There are differences in image quality in thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection techniques, with p-value <0.001. There are differences in the anatomical information of thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection technique with a p-value of 0.004. Conclusion: Edge detection operator canny techniques are able to lower noise values, improve SNR and improve image anatomy information thorax CT scan in COVID-19 patients.","PeriodicalId":33576,"journal":{"name":"Journal of Vocational Health Studies","volume":"20 19","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"EFFECTIVENESS EDGE DETECTION OPERATOR CANNY TO IMPROVE IMAGE QUALITY THORAX CT SCAN IN CASES COVID-19\",\"authors\":\"None Prima Selvia Megawati, None M. Choiroel Anwar, None Fatimah, None Sudiyono, None Darmini, None Saifudin\",\"doi\":\"10.20473/jvhs.v7.i2.2023.77-82\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Thorax CT scan is one of the medical supports that contributes most importantly to the diagnosis, especially cases of COVID-19. The disadvantage that has a CT scan image is noise. When the noise is high then the Signal Noise Ratio (SNR) value produced is low. Canny operator edge detection technique is one solution to animate noise. Purpose: Analyzing differences in image quality and anatomical information on thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection techniques. Method: A quasi experimental research on thorax CT Scan images before and after the application of canny operator edge detection which amounted to 10 samples. Image assessment is done by measuring noise, SNR, and anatomical information. Differences in image quality (noise and SNR) are tested with paired T-tests. Anatomical information is tested with the Wilcoxon Signed Rank Test. Result: There are differences in image quality in thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection techniques, with p-value <0.001. There are differences in the anatomical information of thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection technique with a p-value of 0.004. Conclusion: Edge detection operator canny techniques are able to lower noise values, improve SNR and improve image anatomy information thorax CT scan in COVID-19 patients.\",\"PeriodicalId\":33576,\"journal\":{\"name\":\"Journal of Vocational Health Studies\",\"volume\":\"20 19\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vocational Health Studies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20473/jvhs.v7.i2.2023.77-82\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vocational Health Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20473/jvhs.v7.i2.2023.77-82","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:胸部CT扫描是对新冠肺炎诊断最重要的医学支持之一。CT扫描图像的缺点是噪声。当噪声较高时,产生的信噪比(SNR)值较低。Canny算子边缘检测技术是解决动态噪声的一种方法。目的:分析应用canny算子边缘检测技术前后新冠肺炎患者胸部CT扫描图像质量及解剖信息的差异。方法:对应用canny算子边缘检测前后的10张胸腔CT扫描图像进行准实验研究。图像评估是通过测量噪声、信噪比和解剖信息来完成的。图像质量(噪声和信噪比)的差异用配对t检验进行检验。解剖信息用Wilcoxon符号秩检验进行检验。结果:应用canny算子边缘检测技术前后,COVID-19患者胸部CT扫描图像质量存在差异,p值为<0.001。canny算子边缘检测技术应用前后COVID-19患者胸部CT扫描图像解剖信息存在差异,p值为0.004。结论:边缘检测算子canny技术能够降低新冠肺炎患者胸部CT扫描的噪声值,提高信噪比,改善图像解剖信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
EFFECTIVENESS EDGE DETECTION OPERATOR CANNY TO IMPROVE IMAGE QUALITY THORAX CT SCAN IN CASES COVID-19
Background: Thorax CT scan is one of the medical supports that contributes most importantly to the diagnosis, especially cases of COVID-19. The disadvantage that has a CT scan image is noise. When the noise is high then the Signal Noise Ratio (SNR) value produced is low. Canny operator edge detection technique is one solution to animate noise. Purpose: Analyzing differences in image quality and anatomical information on thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection techniques. Method: A quasi experimental research on thorax CT Scan images before and after the application of canny operator edge detection which amounted to 10 samples. Image assessment is done by measuring noise, SNR, and anatomical information. Differences in image quality (noise and SNR) are tested with paired T-tests. Anatomical information is tested with the Wilcoxon Signed Rank Test. Result: There are differences in image quality in thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection techniques, with p-value <0.001. There are differences in the anatomical information of thorax CT scan images in COVID-19 patients before and after the application of canny operator edge detection technique with a p-value of 0.004. Conclusion: Edge detection operator canny techniques are able to lower noise values, improve SNR and improve image anatomy information thorax CT scan in COVID-19 patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
29
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信