{"title":"地球-空气热交换器(EAHE):能量与火用分析","authors":"Wael Zeitoun, Jian Lin, Monica Siroux","doi":"10.21494/iste.op.2023.1014","DOIUrl":null,"url":null,"abstract":"- EAHE is an air-soil exchanger buried under the ground that permits the use of shallow ground temperatures to decrease building’s heating and cooling demands. Exergy analysis, which results from combining both the first and second law of thermodynamics, helps to analyze the performance of the EAHE at its reversible limit and to estimate the departure from this limit. An exergetic analysis will be carried out on the experimental EAHE installed at Illkirch-Graffenstaden campus of University of Strasbourg. The objective is to assess the system and identify the parts that dissipates energy the most to optimize the system. The experimental EAHE and the measurements taken are presented in the analysis and finally the derived results are analyzed","PeriodicalId":483187,"journal":{"name":"Entropie =","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Earth-Air Heat Exchangers (EAHE): Energetic and Exergetic Analysis\",\"authors\":\"Wael Zeitoun, Jian Lin, Monica Siroux\",\"doi\":\"10.21494/iste.op.2023.1014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"- EAHE is an air-soil exchanger buried under the ground that permits the use of shallow ground temperatures to decrease building’s heating and cooling demands. Exergy analysis, which results from combining both the first and second law of thermodynamics, helps to analyze the performance of the EAHE at its reversible limit and to estimate the departure from this limit. An exergetic analysis will be carried out on the experimental EAHE installed at Illkirch-Graffenstaden campus of University of Strasbourg. The objective is to assess the system and identify the parts that dissipates energy the most to optimize the system. The experimental EAHE and the measurements taken are presented in the analysis and finally the derived results are analyzed\",\"PeriodicalId\":483187,\"journal\":{\"name\":\"Entropie =\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Entropie =\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21494/iste.op.2023.1014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Entropie =","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21494/iste.op.2023.1014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Earth-Air Heat Exchangers (EAHE): Energetic and Exergetic Analysis
- EAHE is an air-soil exchanger buried under the ground that permits the use of shallow ground temperatures to decrease building’s heating and cooling demands. Exergy analysis, which results from combining both the first and second law of thermodynamics, helps to analyze the performance of the EAHE at its reversible limit and to estimate the departure from this limit. An exergetic analysis will be carried out on the experimental EAHE installed at Illkirch-Graffenstaden campus of University of Strasbourg. The objective is to assess the system and identify the parts that dissipates energy the most to optimize the system. The experimental EAHE and the measurements taken are presented in the analysis and finally the derived results are analyzed