David Oks, Symon Reza, Mariano Vázquez-Justes, Guillaume Houzeaux, Brandon Kovarovic, Cristóbal Samaniego, Danny Bluestein
{"title":"中小管交界处大小对TAVR小叶血栓形成的影响:流固耦合分析","authors":"David Oks, Symon Reza, Mariano Vázquez-Justes, Guillaume Houzeaux, Brandon Kovarovic, Cristóbal Samaniego, Danny Bluestein","doi":"10.1101/2023.11.13.23298476","DOIUrl":null,"url":null,"abstract":"\\Purpose: TAVR has emerged as a standard approach for treating severe aortic stenosis patients. However, it is associated with several clinical complications, including subclinical leaflet thrombosis characterized by Hypoattenuated Leaflet Thickening (HALT). A rigorous analysis of TAVR device thrombogenicity considering anatomical variations is essential for estimating this risk. Clinicians use the Sinotubular Junction (STJ) diameter for TAVR sizing, but there is a paucity of research on its influence on TAVR devices thrombogenicity. Methods: A Medtronic Evolut® TAVR device was deployed in three patient models with varying STJ diameters (26, 30, and 34mm) to evaluate its impact on post-deployment hemodynamics and thrombogenicity, employing a novel computational framework combining prosthesis deployment and fluidstructure interaction analysis. Results: The 30 mm STJ patient case exhibited the best hemodynamic performance: 5.94 mmHg mean transvalvular pressure gradient (TPG), 2.64 cm 2 mean geometric orifice area (GOA), and the lowest mean residence time (TR) - indicating a reduced thrombogenic risk; 26 mm STJ exhibited a 10 % reduction in GOA and a 35% increase in mean TPG compared to the 30 mm STJ; 34 mm STJ depicted hemodynamics comparable to the 30 mm STJ, but with a 6% increase in TR and elevated platelet stress accumulation. Conclusion: A smaller STJ size impairs adequate expansion of the TAVR stent, which may lead to suboptimal hemodynamic performance. Conversely, a larger STJ size marginally enhances the hemodynamic performance but increases the risk of TAVR leaflet thrombosis. Such analysis can aid preprocedural planning and minimize the risk of TAVR leaflet thrombosis.","PeriodicalId":478577,"journal":{"name":"medRxiv (Cold Spring Harbor Laboratory)","volume":"97 7","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis\",\"authors\":\"David Oks, Symon Reza, Mariano Vázquez-Justes, Guillaume Houzeaux, Brandon Kovarovic, Cristóbal Samaniego, Danny Bluestein\",\"doi\":\"10.1101/2023.11.13.23298476\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\\\Purpose: TAVR has emerged as a standard approach for treating severe aortic stenosis patients. However, it is associated with several clinical complications, including subclinical leaflet thrombosis characterized by Hypoattenuated Leaflet Thickening (HALT). A rigorous analysis of TAVR device thrombogenicity considering anatomical variations is essential for estimating this risk. Clinicians use the Sinotubular Junction (STJ) diameter for TAVR sizing, but there is a paucity of research on its influence on TAVR devices thrombogenicity. Methods: A Medtronic Evolut® TAVR device was deployed in three patient models with varying STJ diameters (26, 30, and 34mm) to evaluate its impact on post-deployment hemodynamics and thrombogenicity, employing a novel computational framework combining prosthesis deployment and fluidstructure interaction analysis. Results: The 30 mm STJ patient case exhibited the best hemodynamic performance: 5.94 mmHg mean transvalvular pressure gradient (TPG), 2.64 cm 2 mean geometric orifice area (GOA), and the lowest mean residence time (TR) - indicating a reduced thrombogenic risk; 26 mm STJ exhibited a 10 % reduction in GOA and a 35% increase in mean TPG compared to the 30 mm STJ; 34 mm STJ depicted hemodynamics comparable to the 30 mm STJ, but with a 6% increase in TR and elevated platelet stress accumulation. Conclusion: A smaller STJ size impairs adequate expansion of the TAVR stent, which may lead to suboptimal hemodynamic performance. Conversely, a larger STJ size marginally enhances the hemodynamic performance but increases the risk of TAVR leaflet thrombosis. Such analysis can aid preprocedural planning and minimize the risk of TAVR leaflet thrombosis.\",\"PeriodicalId\":478577,\"journal\":{\"name\":\"medRxiv (Cold Spring Harbor Laboratory)\",\"volume\":\"97 7\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"medRxiv (Cold Spring Harbor Laboratory)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1101/2023.11.13.23298476\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"medRxiv (Cold Spring Harbor Laboratory)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1101/2023.11.13.23298476","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
目的:TAVR已成为治疗严重主动脉瓣狭窄患者的标准方法。然而,它与一些临床并发症有关,包括以小叶减薄增厚(HALT)为特征的亚临床小叶血栓形成。考虑到解剖变异,对TAVR装置致血栓性进行严格的分析对于估计这种风险至关重要。临床医生使用窦管交界处(STJ)直径来确定TAVR的尺寸,但关于其对TAVR装置血栓形成性影响的研究很少。方法:将美敦力Evolut®TAVR装置部署在三种不同STJ直径(26,30和34mm)的患者模型中,采用结合假体部署和流固相互作用分析的新型计算框架,评估其对部署后血流动力学和血栓形成性的影响。结果:30mm STJ患者血流动力学表现最佳:平均经瓣压力梯度(TPG)为5.94 mmHg,平均几何孔面积(GOA)为2.64 cm 2,平均停留时间(TR)最低,表明血栓形成风险降低;与30 mm STJ相比,26 mm STJ的GOA减少了10%,平均TPG增加了35%;34 mm STJ的血流动力学与30 mm STJ相当,但TR增加6%,血小板应激积累升高。结论:较小的STJ尺寸不利于TAVR支架的充分扩张,可能导致血流动力学性能不理想。相反,较大的STJ尺寸略微提高了血流动力学性能,但增加了TAVR小叶血栓形成的风险。这样的分析可以帮助术前规划和最小化TAVR小叶血栓形成的风险。
Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis
\Purpose: TAVR has emerged as a standard approach for treating severe aortic stenosis patients. However, it is associated with several clinical complications, including subclinical leaflet thrombosis characterized by Hypoattenuated Leaflet Thickening (HALT). A rigorous analysis of TAVR device thrombogenicity considering anatomical variations is essential for estimating this risk. Clinicians use the Sinotubular Junction (STJ) diameter for TAVR sizing, but there is a paucity of research on its influence on TAVR devices thrombogenicity. Methods: A Medtronic Evolut® TAVR device was deployed in three patient models with varying STJ diameters (26, 30, and 34mm) to evaluate its impact on post-deployment hemodynamics and thrombogenicity, employing a novel computational framework combining prosthesis deployment and fluidstructure interaction analysis. Results: The 30 mm STJ patient case exhibited the best hemodynamic performance: 5.94 mmHg mean transvalvular pressure gradient (TPG), 2.64 cm 2 mean geometric orifice area (GOA), and the lowest mean residence time (TR) - indicating a reduced thrombogenic risk; 26 mm STJ exhibited a 10 % reduction in GOA and a 35% increase in mean TPG compared to the 30 mm STJ; 34 mm STJ depicted hemodynamics comparable to the 30 mm STJ, but with a 6% increase in TR and elevated platelet stress accumulation. Conclusion: A smaller STJ size impairs adequate expansion of the TAVR stent, which may lead to suboptimal hemodynamic performance. Conversely, a larger STJ size marginally enhances the hemodynamic performance but increases the risk of TAVR leaflet thrombosis. Such analysis can aid preprocedural planning and minimize the risk of TAVR leaflet thrombosis.