Ján Kosiba, Gabriela Čurgaliová, Zdenko Tkáč, Juraj Jablonický, Liudmyla Hanushchak-Yefimenko, Tetiana Bukoros
{"title":"调节和非调节液压泵的试验","authors":"Ján Kosiba, Gabriela Čurgaliová, Zdenko Tkáč, Juraj Jablonický, Liudmyla Hanushchak-Yefimenko, Tetiana Bukoros","doi":"10.2478/ata-2023-0031","DOIUrl":null,"url":null,"abstract":"Abstract This article deals with the testing of regulating and non-regulating hydraulic pumps in laboratory conditions. The laboratory test was carried out on the hydraulic device consisting of two separate hydraulic circuits (for testing the non-regulating hydraulic pump and regulating hydraulic pump). A throttle valve or proportional throttle valve is used for loading. During the laboratory tests, the flow efficiency of the non-regulating hydraulic pump at rotation speed n = 1,500 rpm (nominal speed) was η pp = 98.91% (0 MPa) and η pp = 94.97% (20 MPa), and for the regulating hydraulic pump, the values were η pp = 97.57% (0 MPa) and η pp = 94.54% (20 MPa). The determined values of flow efficiency of hydraulic pumps determine the correct operation of the experimental hydraulic laboratory equipment.","PeriodicalId":43089,"journal":{"name":"Acta Technologica Agriculturae","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-11-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Testing of Regulating and Non-Regulating Hydraulic Pumps\",\"authors\":\"Ján Kosiba, Gabriela Čurgaliová, Zdenko Tkáč, Juraj Jablonický, Liudmyla Hanushchak-Yefimenko, Tetiana Bukoros\",\"doi\":\"10.2478/ata-2023-0031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This article deals with the testing of regulating and non-regulating hydraulic pumps in laboratory conditions. The laboratory test was carried out on the hydraulic device consisting of two separate hydraulic circuits (for testing the non-regulating hydraulic pump and regulating hydraulic pump). A throttle valve or proportional throttle valve is used for loading. During the laboratory tests, the flow efficiency of the non-regulating hydraulic pump at rotation speed n = 1,500 rpm (nominal speed) was η pp = 98.91% (0 MPa) and η pp = 94.97% (20 MPa), and for the regulating hydraulic pump, the values were η pp = 97.57% (0 MPa) and η pp = 94.54% (20 MPa). The determined values of flow efficiency of hydraulic pumps determine the correct operation of the experimental hydraulic laboratory equipment.\",\"PeriodicalId\":43089,\"journal\":{\"name\":\"Acta Technologica Agriculturae\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-11-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Technologica Agriculturae\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/ata-2023-0031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"AGRICULTURE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Technologica Agriculturae","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ata-2023-0031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AGRICULTURE, MULTIDISCIPLINARY","Score":null,"Total":0}
Testing of Regulating and Non-Regulating Hydraulic Pumps
Abstract This article deals with the testing of regulating and non-regulating hydraulic pumps in laboratory conditions. The laboratory test was carried out on the hydraulic device consisting of two separate hydraulic circuits (for testing the non-regulating hydraulic pump and regulating hydraulic pump). A throttle valve or proportional throttle valve is used for loading. During the laboratory tests, the flow efficiency of the non-regulating hydraulic pump at rotation speed n = 1,500 rpm (nominal speed) was η pp = 98.91% (0 MPa) and η pp = 94.97% (20 MPa), and for the regulating hydraulic pump, the values were η pp = 97.57% (0 MPa) and η pp = 94.54% (20 MPa). The determined values of flow efficiency of hydraulic pumps determine the correct operation of the experimental hydraulic laboratory equipment.
期刊介绍:
Acta Technologica Agriculturae is an international scientific double-blind peer reviewed journal focused on agricultural engineering. The journal is multidisciplinary and publishes original research and review papers in engineering, agricultural and biological sciences, and materials science. Aims and Scope Areas of interest include but are not limited to: agricultural and biosystems engineering; machines and mechanization of agricultural production; information and electrical technologies; agro-product and food processing engineering; physical, chemical and biological changes in the soil caused by tillage and field traffic, soil working machinery and terramechanics; renewable energy sources and bioenergy; rural buildings; related issues from applied physics and chemistry, ecology, economy and energy.